●High-degreed winding protection ensure normal operation under 95% relative humidity
●Several winding types, to adapt to voltage requirement of different occasions.
●Good performance under distortion load.
●Can be easily re-take Lead line of generators to change the output voltage. Reliable AREP and leading excitation system
●AVR sealed with solid epoxy resin can resist all kinds of peak vibration, as well as a variety of adverse circumstances.
●Shunt self-excitation system, applied in three-phase, such as short-circuit or strong excitation occasions. AREP and Shunt+ PMG excitation system is applied in special occasion or short-circuit ability required occasion.
●Compact, good start-up performance and short-circuit capacity.
●Industry's leading brushless excitation system to ensure reliable operation of generators.
●Accuracy rate of voltage will be up to 0.5% at regular steady-state running speed.
●Load regulation module function can ease the impact on the engine caused by competitive changes of load.
Temperature�?20℃~60�?/DIV>
Relative humidity:95%
Voltage:DC24V(range:18-30V,anti-voltage:50V/5mm)
Function and Features:
●Small, reliable and simple to operate, clear lines within, simple and easy to detect.
●Automatic detection and a variety of protection, keep oil safety and stable operation
●Multi-display interface unit and alarming state, clear and intuitive
●Input, output, alarm, delay and other parameters can be set on the microcomputer control panel display.
●various work modes, such as maintenance , manual & automatic operation
●Abnormal start powered by main
●LCD (Liquid crystal display) of the diesel engine parameters
●Gen-sets detective shutdown
●LCD alarming display, control of sound and light alarm output
●With manual, automatic, three-remote function, automatic switch between main and generation power
●Support RS232/RS485 communication mode
●Protection functions including generator over-voltage, under-voltage, low-frequency, high-frequency, low-speed, over-speed, low oil pressure, high water temperature, emergency stop, battery over-voltage, under-voltage, over-current, short circuit, etc.
●Historical state records provided
Deep-sea 5510 Parallel Module for Option
Fully Automatic Parallel Control Box
●Self-start, safety protection and alarming
●Manual and self-parallel
●Automatic load distribution
●Automatic unavailable power distribution
●Automatically retreat from gen-set based on load variation
●Control a parallel of 16 units at most.
●Open type agreement MODBUS provided, RS 232 AND RS 485 Communications interface monitoring
●With manual, automatic, three-remote function, computer monitoring
●Protection functions including generator over-voltage, low -voltage, low-frequency, high-frequency, low-speed,
over-speed, low oil pressure , high water temperature, emergency stop, battery over-voltage, under-voltage, over-current, short circuit, etc
The scope of supply
Notes: Attachments symbled by * are attachments installed on generating set already