P/F: ELECTRICAL ACTUATOR "METSO-JAMESBURY" SUPPLY: 115 VAC, AMPS: 0.6 A, DUTY CYCLE: 75% CYCLE TIME: 15 DEC/90 DEG. GE P/N: GE311A5449P005/P006 TAG NO: 20TW-1/3 ELECTRICAL ACTUATOR COMPLETE. P/N: GE311A5449P005 SUPPLIER: METSO-JAMESBURY. P/F: ELECTRICAL ACTUATOR "METSO-JAMESBURY" SUPPLY: 115 VAC, AMPS: 0.6 A, DUTY CYCLE: 75% CYCLE TIME: 15 DEC/90 DEG. GE P/N: GE311A5449P005/P006 TAG NO: 20TW-1/3 ELECTRICAL ACTUATOR COMPLETE. P/N: GE311A5449P006 SUPPLIER: METSO-JAMESBURY.
JAMESBURY® VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC
GENERAL Metso is a leading designer and provider of compact, reliable, electronically controlled electric actuators for valves and dampers. We offer a complete line of Valvcon electric actuators for accurate positioning of dampers and valves in the aerospace, automotive, consumer services, discrete manufacturing, energy, environmental, oil/pipeline, petrochemical, power/utilities, process, recreation, transportation, and water/wastewater industries.
Metso has developed and introduced the industry’s most innovative electric actuator features, including simple "set and go" calibration, intelligent processor-based digital electronics, "plug-in" accessory boards, back-up power, as well as electric actuators designed for remote control, solar-powered applications and two-wire network applications. Metso has built its reputation and success on the ability to envision, implement, and deliver innovative Valvcon actuator technology products and services to support emerging market requirements. As emerging technologies and market needs continue to evolve, Metso will lead the way with high quality Jamesbury Valvcon electric actuators that exceed industry expectations and further refine the valve actuation process.
115VAC AND 230VAC MODELS*
Torque Output (breakaway) |
Speed (seconds per 90º rotation) |
Duty Cycle |
VA Rating |
Max Running Current at Full Load (True RMS) |
Max Effective Peak Inrush Current (= .66 x peak inrush) |
|
|
|
115VAC |
230VAC |
115VAC |
230VAC |
115VAC |
230VAC |
150 in lb |
8 |
75% |
70VA |
115VA |
.6 amps |
.5 amps |
1.25 amps |
.924 amps |
300 in lb |
15 |
75% |
70VA |
115VA |
.6 amps |
.5 amps |
1.25 amps |
.924 amps |
600 in lb |
30 |
75% |
70VA |
115VA |
.6 amps |
.5 amps |
1.25 amps |
.924 amps |
1000 in lb |
25 |
75% |
92VA |
161VA |
.8 amps |
.7 amps |
1.66 amps |
1.29 amps |
1500 in lb |
40 |
75% |
92VA |
161VA |
.8 amps |
.7 amps |
1.66 amps |
1.29 amps |
2000 in lb |
55 |
75% |
92VA |
161VA |
.8 amps |
.7 amps |
1.66 amps |
1.29 amps |
2500 in lb |
70 |
75% |
92VA |
161VA |
.8 amps |
.7 amps |
1.66 amps |
1.29 amps |
3000 in lb |
75 |
55% |
92VA |
161VA |
.8 amps |
.7 amps |
1.66 amps |
1.29 amps |
*Notes: 1. The Maximun Current stated above includes all options. If the brake and/or heater & thermostat are not installed, the actual current draws will be less.
HOW TO ORDER - V & LV-SERIES ELECTRIC ACTUATORS (A200-1)
Example: |
|
|
1 |
2 |
3 |
4 |
5 |
6 |
Sample model code: |
|
|
LV |
W |
1500 |
C |
H,I,K,S2 |
N230AC |
LV W 1500 C HIKS2 N230AC |
|
|
|
|
|
|
|
|
|
|
|
|
1 |
Series |
|
4 |
Board Options* |
V |
V |
|
- |
No Entry If Standard |
LV |
LV |
|
C |
Control Board |
|
|
|
J |
Speed Control Timer Board |
2 |
Enclosure |
|
U |
Iso/Readback Board |
W |
Weathertight (NEMA 4/4X) |
|
|
|
|
|
|
|
WX |
Weathertight & Explosionproof (NEMA 4/4X/7 & 9) |
|
5 |
Other Options |
|
|
|
|
- |
No Entry If Standard |
3 |
Torque (in lbs) |
|
H1 |
Tropical Heater/Thermostat |
150 |
150 |
 /SPAN> |
|
I2 |
ISO 5211 Compliant Output |
300 |
300 |
V-Series Only |
|
K |
Brake |
600 |
600 |
 /SPAN> |
|
P |
Feedback Potentiometer |
1000 |
1000 |
|
|
S2 |
2 Additional Limit Switches |
1500 |
1500 |
|
|
T3 |
Heater/Thermostat |
2000 |
2000 |
LV-Series Only |
|
Y4 |
Keyed Output |
2500 |
2500 |
|
|
Z |
Handwheel |
3000 |
3000 |
|
|
|
|
|
|
|
|
|
|
|
|
6 |
Operating Voltage |
|
|
|
|
N115AC |
115VAC |
|
|
|
|
N230AC |
230VAC |
|
|
|
|
Notes: |
|
|
|
|
|
* Select only one board option as needed. 1. This heater option activates at or below 90°F and deactivates at 110°F; it is recommended high-humidity applications. 2. 150-600 in-lb models with option "I" are supplied with a 14mm female square. (note: without option "I" the female square is 3/4 inch). 1000 in-lb models with option "I" are supplied with a 19mm female square and 1500-3000 in-lb models are supplied with a 22mm female square. (note: without option "I" the female square is 1inch). 3. This heater option activates at or below 40°F and deactivates at 60°F; it is recommended in applications were temperature may drop below 32°F. 4. 150 - 600 lb-in models with "Y" option are supplied with a 15mm female keyed output. 1000 - 3000 lb-in models with "Y" option are supplied with a 20mm female keyed output. | |