Item |
Catalogue Desription |
Part Description |
Quoted P/N |
RUT2013000060 A - GT Generator Control & Protection Spares (Electrical Spares) |
19 |
Device Name: TBDC, TBAC, TBCT, TBVT, TBOA, TBAO, TBIA, TBIB, TBIC, TBEX |
Terminal Blocks Rated Voltage 800V, Rated Current 41A, Rated Cross Section 0.5-6mm2, Din rail, slide link |
Model No. WTL 6/1/STB (1016900000), (WEIDMULLER) |
20 |
Device Name: TBAO |
Terminal Blocks Rated Voltage 500V, Rated Current 32A, Rated Cross Section 0.5-4mm2, Din rail, slide link |
Model No. WTL 4/STB (1754970000), (WEIDMULLER) |
21 |
Device Name: TBEX1, 2, 3, 4, 5, 6, 7 |
Terminal Blocks Rated Voltage 500V, Rated Current 125A, Rated Cross Section 4-35mm2, Din rail, slide link |
Model No. WTL 35/2/STB (1925030000), (WEIDMULLER) |
RUT2013000059 - Procurement of GT MCC Critical Spares |
 /B> |
1 |
Green Pushbutton, 1NO + 1NC |
ABB |
CP1-10G-11 |
2 |
Black Pushbutton, 1NO + 1NC |
ABB |
CP1-10B-11 |
3 |
Yellow Pushbutton, 1NO + 1NC |
ABB |
CP1-10Y-11 |
4 |
Green Pushbutton, 2NO |
ABB |
CP1-10G-20 |
5 |
Black Pushbutton, 2NC |
ABB |
CP1-10B-02 |
6 |
White Indication Lamp LED, 130Vdc |
ABB |
CL-515W |
7 |
Red Indication Lamp LED, 130Vdc |
ABB |
CL-515R |
8 |
Green Indication Lamp, LED, 130Vdc |
ABB |
CL-515G |
9 |
Yellow Indication Lamp, LED, 130Vdc |
ABB |
CL-515Y |
10 |
Blue Indication Lamp, LED, 130Vdc |
ABB |
CL-515L |
11 |
Auxiliary Relay + Base, Coil: 230Vac 4 conmuted |
ABB |
CR-M230AC4+CR-M4LS+CR-MH |
12 |
Manual Circuit Breaker, 45A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB45J6, Shaft OXP6x170 |
ABB |
OT63F3 |
13 |
Contactor Starter, 50A, Aux Voltage 230Vac |
ABB |
A50-30-11 |
14 |
Auxiliary Contacts, 1NC |
ABB |
CA5-01 |
15 |
Auxiliary Contacts, 1NO |
ABB |
CA5-10 |
16 |
Thermal Relay, Class 10, Range 24-32A |
ABB |
TA25DU32 |
17 |
Thermal Relay Support |
ABB |
DB 25/32A MOUNT. KIT FOR TA25DU32 Ref: 82500212 |
18 |
Fuse Monitoring System |
ABB |
OFM690 |
19 |
Manual Circuit Breaker, 200A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB65J6, Shaft OXP6x210 |
ABB |
OT200E03P |
20 |
Contactor Starter, 300A, Aux Voltage 230Vac |
ABB |
A300-30-11 |
21 |
Auxilliary Contacts, 1NO+1NC |
ABB |
CAL-18-11 |
22 |
Auxilliary Contacts, 1NO+1NC |
ABB |
CAL-18-11B |
23 |
Thermal Relay, Class 10, Range 130-175A |
ABB |
TA200DU175 |
24 |
Thermal Relay Support |
ABB |
DB 200 MOUNT.KIT F. TA110 Ref: 82500210 |
25 |
Manual Circuit Breaker, 75A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB45J6, Shaft OXP6x170 |
ABB |
OT80F3 |
26 |
Contactor Starter, 110A, Aux Voltage 230Vac |
ABB |
A110-30-11 |
27 |
Thermal Relay, Class 10, Range 60-80A |
ABB |
TA75DU80 |
28 |
Thermal Relay Support |
ABB |
DB 80 MOUNT.KIT F. TA42.TA75.TA80 Ref: 82500213 |
29 |
Manual Circuit Breaker, 90A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB45J6, Shaft OXP6x170 |
ABB |
OT125F3 |
30 |
Contactor Starter, 185A, Aux Voltage 230Vac |
ABB |
A185-30-11 |
31 |
Thermal Relay, Class 10, 20, 30 selectable, Range 50-140A |
ABB |
E140DU140 |
32 |
Thermal Relay Support |
ABB |
DB140E |
33 |
Manual Circuit Breaker, 16A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB45J6, Shaft OXP6x210 |
ABB |
OT16F3 |
34 |
Contactor Starter, 9A, Aux Voltage 230Vac |
ABB |
A9-30-10 |
35 |
Mechanical Interlocking, 2NC Contacts |
ABB |
VE5-1 |
36 |
Thermal Relay, Class 10, Range 4.5-6.5A |
ABB |
TA25DU6.5 |
37 |
Thermal Relay Support |
ABB |
DB 25/25A MOUNT. KIT FOR TA25 <=25A Ref: 82500211 |
38 |
Contactor Starter, 65A, Aux Voltage 230Vac |
ABB |
A63-30-11 |
39 |
Thermal Relay, Class 10, Range 29-42A |
ABB |
TA42DU42 |
40 |
Thermal Relay, Class 10, 20, 30 selectable, Range 27-80A |
ABB |
E80DU80 |
41 |
Thermal Relay Support |
ABB |
DB80E |
42 |
Manual Circuit Breaker, 80A, Rotative Handle, 3-Pole, Auxiliary Contact Ref OA1G10, Handle Ref OHB45J6, Shaft OXP6x170 |
ABB |
OT100F3 |
43 |
Contactor Starter, 145A, Aux Voltage 230Vac |
ABB |
A145-30-11 |
44 |
Thermal Relay, Class 10, Range 66-90A |
ABB |
TA110DU90 |
45 |
Moulded Case Circuit Breaker 400Vac, 6.3A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Protection |
ABB |
T2S160 TMD6.3/63 FF 3P |
46 |
Moulded Case Circuit Breaker 400Vac, 8.5A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Protection |
ABB |
T2S160 MF8.5/110 FF 3P |
47 |
Moulded Case Circuit Breaker, 400Vac, 10A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
ABB |
T2S160 TMD10/100 FF 3P |
48 |
Moulded Case Circuit Breaker 400Vac, 20A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
ABB |
T2S160 TMD20/500 FF 3P |
49 |
Moulded Case Circuit Breaker, 400Vac, 16A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
ABB |
T2S160 TMD16/500 FF 3P |
50 |
Moulded Case Circuit Breaker 400Vac, 200A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Unit Mag Break |
ABB |
T3S250 MA200/1200-2400 FF 3P |
51 |
Moulded Case Circuit Breaker, 400Vac, 32A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Protection |
ABB |
T2S160 MA32/192-384 FF 3P |
52 |
Moulded Case Circuit Breaker, 400Vac, 50A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
ABB |
T2S160 TMD50/500 FF 3P |
53 |
Moulded Case Circuit Breaker, 400Vac, 80A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
ABB |
T2S160 TMD80/800 FF 3P |
54 |
Auxiliary Contact , 3x(NO+NC) + 1 trip relay contact, 250VAC/DC T1-T6 Ref: 1SDA051369R1, 10044062 |
ABB |
AUX-C 3Q1SY-Cabled 250Vac/dc T1-3 |
55 |
Auxiliary Contact , 1x(NO+NC) + 1 trip relay contact, 250VAC/DC T1-T6 Ref: 1SDA051368R1, 10044061 |
ABB |
AUX-C 1Q1SY-Cabled 250Vac/dc T1-3 |
56 |
Padlocking for T2 and T3 |
ABB |
Type: 1SDA051394R1, Ref: 10044131 |
57 |
Auxiliary Relay + Base, Coil: 125Vdc, 4 conmuted |
ABB |
Type: CR-M125DC4L+CR-M4SS+CR-MH |
58 |
Power Supply, 24Vdc, 2.5A |
ABB |
Type: CP-E24/2.5 |
59 |
2 Position Selector Switch, 1NO+1NC, Auto Return |
ABB |
C2SS3-10B-11 |
60 |
Contactor Starter, 125Vdc, Power Contacts NO |
ABB |
Type: IORE 170-10 |
61 |
Contactor Starter, 125Vdc, Power Contacts NC+CA12-1 |
ABB |
Type: NORE 125-01 |
62 |
Auxiliary Contact For NORE |
ABB |
Type: CA12-1 |
63 |
Auxiliary Relay, Coil: 100-250Vdc, 4NO |
ABB |
NF40E-13*100-250V AC/DC |
64 |
Auxiliary Contacts, 1NO+1NC |
ABB |
Type: CALA-11 |
65 |
Motor Bus Transfer System or High Speed Transfer Device, 5A, 50Hz, Nominal Sensing Inputs, 80-315.5Vdc Power Input, 110/125Vdc trip/close circuit monitoring input, ABC Phase Rotation |
Arteche |
M-4272 |
66 |
Under Voltage Relay, 3-Pole, 400Vac, Feed: 125Vdc |
Arteche |
RV-UT.140100000 |
67 |
Current Transformer, 2000/5, 10VA, Class 0.5 |
Carlo Gavazzi |
TAD8 |
68 |
Shunt |
Celsa |
Type: 600A/300mV, Class: 0.5 |
69 |
Fuse 2A, Size: 10x38, 2A, gL/gG |
Chint |
RT28-32 |
70 |
Fuse Link, Size NH 00 |
Chint |
RT36-00-40/aM |
71 |
Fuse Base, NH00, 1 Pole |
Chint |
RT36-00 |
72 |
Fuse Link, Size NH 1 |
Chint |
RT36-1-200/aM |
73 |
Fuse Base, NH1, 1 Pole |
Chint |
RT36-1 |
74 |
Fuse Link, Size NH 00 |
Chint |
RT36-00-80/aM |
75 |
Fuse Link, Size NH 00 |
Chint |
RT36-00-125/aM |
76 |
Fuse Link, Size NH 00 |
Chint |
RT36-00-6/aM |
77 |
Fuse Link, Size NH 00 |
Chint |
RT36-00-50/aM |
78 |
2-Position Selector Switch |
Chint |
LW5D-3 |
79 |
Current Transformer, 2000/5, 10VA, Class 0.5, 20VA |
Chint |
BH-0.6680 2000/5 |
80 |
Shunt |
Complee |
Type: FL2 250A/100mV |
81 |
Voltage Transformer One Phase, First Voltage: 400Vac, Second Voltage: 100Vac, Class: 0.5, Rated Output: 15VA |
Complee |
KLY-PT-JDG4-400/100 |
82 |
Voltage Distributor, 2-Pole, 16 Outputs, 40A, DIN fix |
ERICO |
Type: BD40A, Ref: 563720 |
83 |
Circuit Breaker, 230Vdc, 4A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE |
G62C04, Ref: 674632 |
84 |
Contactor, 32A, Coil Voltage: 77-143Vdc |
GE-Power Control |
CL04D310MWJ |
85 |
Auxiliary Contact, Ref: 104707, 1NO+1NC |
GE-Power Control |
BCLL11 |
86 |
Auxiliary Contact, Ref: 106622, 2NC |
GE-Power Control |
BRLL02 |
87 |
Moulded Case Circuit Breaker, 415Vac, 200A, 3-Pole, Moulded Case Type, Fixed, With Thermal and Magnetic Protection |
GE-Power Control |
FEN36TD200KF |
88 |
Auxiliary Contact for FD/FE, 1NO |
GE-Power Control |
Type: FAS10R, Ref: 430837 |
89 |
Auxiliary Contact for FE, Bell alarm mechanism unit, 1NO |
GE-Power Control |
Type: FABAM10, Ref: 432003 |
90 |
Padlocking for FD/FE |
GE-Power Control |
Type: FD 1 PR, Ref: 430879 |
91 |
Contactor, 9A, Coil Voltage 77-143Vdc |
GE-Power Control |
CL00D310TWJ |
92 |
Circuit Breaker, 230Vdc, 2A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C02, Ref: 674630 |
93 |
Circuit Breaker, 230Vdc, 6A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C06, Ref: 674633 |
94 |
Circuit Breaker, 230Vdc, 10A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C10, Ref: 674635 |
95 |
Circuit Breaker, 230Vdc, 16A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C16, Ref: 674637 |
96 |
Circuit Breaker, 230Vac, 50/60Hz, 25A, 2-pole, Modular type, fixed, with thermal and magnetic unit. 10KA according to IEC 60947-2 |
GE-Power Control |
Type: G62C25, Ref: 674639 |
97 |
Circuit Breaker, 230Vac, 50/60Hz, 40A, D curve, 1-pole, Modular type, fixed, with thermal and magnetic unit. 10KA according to IEC 60947-2 |
GE-Power Control |
Type: G61D40, Ref: 674771 |
98 |
Earth Fault Protection Module, For Circuit Breaker, 30mA |
GE-Power Control |
Type: DOC232/030 |
99 |
Earth Fault Protection Module, For Circuit Breaker, 300mA |
GE-Power Control |
DOC232/300 |
100 |
Auxiliary Contact, Function: H |
GE-Power Control |
Type: CAH, Ref: 672567 |
101 |
Auxiliary Contact, Function: S/H |
GE-Power Control |
Type: CAS/H, Ref: 672568 |
102 |
Padlock for G60 |
GE-Power Control |
Type: KS, Ref: 624929 |
103 |
Circuit Breaker, 230Vac, 50/60Hz, 16A, D curve, 2-pole, Modular type, fixed, with thermal and magnetic unit. 10KA according to IEC 60947-2 |
GE-Power Control |
Type: G62D16, Ref: 674799 |
104 |
Circuit Breaker, 230Vac, 50/60Hz, 25A, D curve, 2-pole, Modular type, fixed, with thermal and magnetic unit. 10KA according to IEC 60947-2 |
GE-Power Control |
Type: G62D25, Ref: 674801 |
105 |
Moulded Case Circuit Breaker, 125Vdc, 160A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Unit Mag Break |
GE-Power Control |
Type: FEN36MC160JF |
106 |
Moulded Case Circuit Breaker, 125Vdc, 800A, 3-Pole, Moulded Case Type, Fixed |
GE-Power Control |
Type: FKY306DN800PF, Ref: 435495 |
107 |
Trip Moudle for FK |
GE-Power Control |
Type: FNSHTD, Ref: 435693 |
108 |
Auxiliary Contact For FK |
GE-Power Control |
Type: FNS11R, Ref: 436401 |
109 |
Padlock for FK |
GE-Power Control |
Type: FN1PR, Ref: 433417 |
110 |
Battery Protection Relay |
GE-Power Control |
Type: RPB45S |
111 |
Contactor 25A, Coil Voltage: 77-143Vdc |
GE-Power Control |
CL25D300TWJ |
112 |
Circuit Breaker, 125Vdc,25A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C25, Ref: 674639 |
113 |
Circuit Breaker, 125Vdc, 40A, 2-pole, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G62C40, Ref: 674641 |
114 |
Circuit Breaker, 125Vdc, 50A, 4-pole, D curve, Modular type, fixed, with thermal and magnetic unit |
GE-Power Control |
Type: G64D50, Ref: 674836
|
115 |
Circuit Breaker, 230Vac, 50/60Hz, 2A, D curve, 2-Pole, Modular type, fixed, with thermal and magnetic unit. 10KA according to IEC 60947-2 |
GE-Power Control |
Type: G62D02 |
116 |
Moulde Case Circuit Breaker, 125Vdc, 7A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Unit, Mag Break, 50KA |
GE-Power Control |
Type: FDN36MC007ED, Ref. 430095 |
117 |
MCB Rotate Handle, Direct On Device, Grey |
GE-Power Control |
Type: FDNRF/5, Ref: 436478 |
118 |
MCB Key, Direct On Device, Ronis Lock With Random Key |
GE-Power Control |
Type: FA1BR1, Ref: 430088 |
119 |
Moulde Case Circuit Breaker, 125Vdc, 125A, 3-Pole, Moulded Case Type, Fixed, With Magnetic Unit, Mag Break |
GE-Power Control |
Type: FEN36MC125JF |
120 |
Auxiliary Contact for FD, Bell Alarm Trip Unit, 1NO+1NC |
GE-Power Control |
Type: FDBAM11, Ref: 430880 |
121 |
MCB Rotate Handle, Direct On Device, Grey |
GE-Power Control |
Type: FENRF/5, Ref: 436495 |
122 |
Fuse Base, Size: 10x38, 1 phase |
Hager |
LS501 |
123 |
Fuse Base, Size: 10X38, 3 Phase |
Hager |
LS503 |
124 |
Starting Resistor |
KLK |
0.25 Ohm, 1.7Sec |
125 |
Starting Resistor |
KLK |
0.075 Ohm, 2.2Sec |
126 |
Current Transducer |
LEM |
Type: DHR300-C420 |
127 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 16-25A |
Moeller |
PKZ2+ZM-25-8-PKZ2 |
128 |
Auxilliary Contacts for Disjuntor PKZ2, 2NO+2NC |
Moeller |
NH12-11S-PKZ2 |
129 |
Fault Contact for Disjuntor PKZ2, 1NO+1NC |
Moeller |
AGM2-11-PKZ2 |
130 |
Contactor-Limiter, 20KW, 100KA, 3-pole, 230Vac, 50/60Hz |
Moeller |
S-PKZ2 |
131 |
Base for Contactor |
Moeller |
C-PKZ2 |
132 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 32-40A |
Moeller |
PKZ2+ZM-40-8-PKZ2 |
133 |
Residual Current Relay |
Moeller |
PFR-003 |
134 |
Ring Type Transformer |
Moeller |
PFR-W-30 |
135 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 6-10A |
Moeller |
PKZ2+ZM-10-8-PKZ2 |
136 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 10-16A |
Moeller |
PKZ2+ZM-16-PKZ2 |
137 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 2.4-4A |
Moeller |
PKZ2+ZM-4-PKZ2 |
138 |
Disjuntor, 40A with thermal and magnetic protection module, thermal regulation 4-6A |
Moeller |
PKZ2+ZM-6-PKZ2 |
139 |
Timing Relay, 125Vdc, 2 Auxiliary Contactors, On delay, Off delay |
Moeller |
Type: ETR4-70-A |
140 |
Diode Terminal Block and Plug, Ref. 2777014, Ref: 2802316, Ref: 2777027 |
Phoenix Contact |
Type: Terminal UDK 4-TG, Plug ST-BE, Cover: D-UDK-RELG |
141 |
One Phase Power Transformer, 2KVA, 400/230Vac, 50Hz |
Polylux |
ND2000 |
142 |
Excitation Transformer, V1: 400+10 Vac, V2: 227 Vac, 50Hz, 10KVA |
Polylux |
Type: Normal Excitation Transformer |
143 |
Ammeter 72x72, 90 Degree, 2000/5 |
Risesun |
BE-72 |
144 |
Voltmeter 72x72, 90 Degree, 0-600V, Direct Connection |
Risesun |
BE-72 |
145 |
Excitation Resistor |
RS (Farnell), 22R |
Type: RSSD25X168 200W5 22R, Ref: 0170203 |
146 |
Resistor Support Type |
RS (Farnell), Premier |
Ref: 121-3360, RS Ref: 168-907 |
147 |
Motor Circuit Breaker, With Thermal and Magnetic Protection, Thermal Regulation: 37-50A |
Schneider |
GV3-P50 |
148 |
Aux Contact + Tripping Contact |
Schneider |
GV-AD0110 |
149 |
Contactor, 230Vac, 50/60Hz, 50A |
Schneider |
LC1-D50AP7 |
150 |
Front Aux Contacts |
Schneider |
LADN11 |
151 |
Contactor, 230Vac, 50/60Hz, 18A |
Schneider |
LC1-D18P7 |
152 |
Selector Switch, Open-Close (2Contacts) |
Schneider |
K2B-006TCHC |
Email: Get Quote