BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   China Small EPC Contractor   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  

Mail List

E-mail:

Power Generation
     Big Power Plant Projects  
     GE Gas Turbine Power Plant Project  
       3x42mw gas turbine plant proposal  
     15MW Heat recovery plant GE 6B Gas Turbine Plant  
     200mw Coal Fired Plant  
     600mw ultra super critical power plant  
     1500mw GE gas turbine plant  
     3x750mw Gas Turbine Combined Cycle Power Plant  
     360000 M3/D Sea Water Desalination  
     geothermal power plant  
       Work Scope  
       Design Data  
       Steam Turbine  
       Cooling System  
       Water System  
       Ventilation  
       Instrumentation Auto.  
       Electrification  
     Diesel power Plant  
     waste heat recovery power plant  
       4.5MW Waste heat recovery 2500t/d Cement Line  
       7.5MW Waste heat recovery 2x2500t/d Cement Line  
       9MW Waste heat recovery 5000t/d Cement Line  
       18MW Waste heat recovery 2x5000t/d Cement Line  
       Technical Proposal of 9MW Recovery Plant  
       Power Plant Connection and Main Equipments  
       Main Equipment Recovery Plant  
       Power Plant Construction Schedule  
       China Reference List waste heat Plants  
       Preliminary Proposal for Cement Plant  
     Thermal Power proposal  
     Questionnaire for Gas/HFO/Liquid Fuel Power Plant  
     Check-List-for-quotation-on-power-plant  
     Power project reference  
       Thermal plant List  
       Foreign Small plant  
       Reference of Sinomach  
       Diesel generator plant list   
       waste heat recovery power plant list  
       Gas Turbine Power plant Reference  
     Indicative quotation of 2x50MW coal fired plant  
     Estimated Quotation for Plant  
     China large scaled industry power project  
     Biomass-Gasification-Power-Generation-System  
     Gas Engine Generator power plant  
       Proposal quotation of 2x2.6mw gas engine generator  
       500kw-5200kw gas engine generator series  
       500kw-5500kw Gas-Duel fuel diesel Generator  
       well-known-diesel-generator-set-and-Gas-genset  
     Solar-Panel-Power-Plant-Quotation  
     China top conveyor belt for power, mining, port  
     Environment-friendly-solar-power-plant  
     China-the-most-famous-gas-engine-generator-sets  
       Natural-Gas-Genset  
       Biogas-Genset-Landfill-gas-Generator-set  
       Coal-Mine-Gas-Genset  
       Biomass-Genset  
       Coal-Gas-Producer-Gas-Genset  
       Low-BTU-Gas-Genset  
       Gas-Engine  
     3mw-and-4mw-gas-genset-by-CNPC-produce  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > Power Generation > Questionnaire for Gas/HFO/Liquid Fuel Power Plant


Google

Questionnaire for gas / HFO liquid fuel Based Power Plant

Information Required for Selection / Sizing/ Design of Power Plant

A SITE CONDITIONS

1) Altitude (m above Sea Level) :-

2) Maximum Ambient Temperature. (° C) :- 45 Degree Cent

3) Relative Humidity at Maximum Ambient ( % ) :-

4) Wet Bulb Temperature of the Area (° C) :-

5) Environment (Dusty / Clean) :- Clean

6) Presence of any Hazardous or Chemically :-Active Gases In Surrounding Air

7) Soil Condition at site (normal, marshy :- Normal black cotton etc.)

8) Soil bearing capacity :-

(< 15 tons/m2 or > 15 tons/m2)

9) Water table at site :-

 

B POWER REQUIREMENT ( As discussed personally present conditions given )

1) Maximum Demand (kVA) :-Max Demand reached in Last 4 Years - KVA

2) Minimum continuous process loads (kVA / kW) :-

3) Grid Voltage and Frequency :- 22 KV ( +/- 10 % ) Variation Percentage :- 50 Hz ( +/- 4% )

4) Whether Independent Auxiliary Power Supply?:- Yes ( 415 V) available

5) Proposed Power Plant capacity (MW) :- Option 1 - for 50 % Load; Option 2 - for 100 % Load

 

C STEAM REQUIREMENT (IF ANY) If system can provide the steam it can be used for preheating in our existing system.

At present we are using thermal oil based heating system

1) For process Steam (Quantity T/hr., :-pressure)

2) For air-conditioning / chillers etc. :-(quantity T/hr., pressure)

3) For fuel heating only :- For Fuel Heating

4) Existing Boiler(s) details :-

 

D FUEL

1) Type of fuel to be used :- HFO/ HPS / LSHS / FO / LDO / HSD / NG / BIOGAS

(Please provide specifications of fuel, in case of Gas Annexure IV shall be filled also)

2) Approximate price of fuel at site (Rs. / kL) :- Rs. 18000 per KL

3) Design Viscosity of Fuel handling System :-(380 or 500 cST at 50° C)

4) Fuel Handling and Storage Facility at site :- Tank of 65 KL capacity (If any for existing Generating Sets)

INFORMATION REQUIRED TO DETERMINE OPERATING PHILOSOPHY

A POWER PLANT OPERATION :- Continuous (Continuous / Base Load / Standby / Emergency / Peaking)

B PARALLEL OPERATION

1) With grid ( Yes / No ) :- Yes

2) Between proposed DG Sets (Yes / No ) :- Yes

3) With existing DG / TG Sets (Yes / No) :- No

Details of existing DG /TG sets (if parallel operations required.)

i) Supplier / Model / Name plate details :- We have Old 180 KVA DG set which are used at present for Emergency Lighting etc incase of Power

shutdown / Breakdown

ii) Rating (kVA / kW) :- 180 KVA * 2 Nos

iii) Make / Model / Type of Governor :- Kirloskar

iv) Type of Excitation / AVR :-

v) Synchronization Facility :-

 

C SPECIAL REQUIREMENTS

1) Motor Starting Duty (If any) :- We have rolling mills. The (If yes, please provide details wherever possible) maximum size of the motor is 750

HP DC having a full load current of 1006 Amp. When it starts from standstill it takes @ 1600 Amp + current.

2) Furnace application :- We have 3 No. Foil

Annealing Furnace. 1350 KW

3) Non-linear Thyristor Loads, if any :- Thyristor drives - Yes

4) Any other non-standard loads, if any :-

5) Voltage requirement (3.3 / 6.6 / 11 kV) :- 3.3 KV ( my existing feeder is 22 KV incoming and Step down to 3.3 KV )

6) Water Availability :-(Sufficient - Cooling Towers, Scarce - Radiators)

If Yes in case of C1, C2 and / or C3 above Annexures - I. II and III (Page 5 of 8, 6 of 8 & 7 of 8) shall be filled also. In case of Non-linear loads please provide harmonics analysis report also.

INFORMATION ABOUT THE CLIENT (PURCHASER / OWNER COMPANY)

1) Contact Person & Designation :-

Office Address / Telephone / Fax # -- –Electrical Industries Ltd

2) Name / address / Tel. of Consultant (if any) :- NA

3) Annual Turnover of the Company :-Plant @ 168 Cr

4) Main Product and installed capacity :-Aluminum. foil & Packaging Products

5) Location of the Site :- Kalwa - Thane

6) Availability for proposed Power plant at site :-

7) Contact Person at Site :- As Above Address / Telephone / Fax #

8) Whether power requirement is for :- Existing Plant existing plant /expansion project / new project

9) Duty structure :-(EPCG / EOU / Project Import / IPP)

10) Project Implementation Schedule :- FY 07-08 (Power Out - month / year)

11) Mode of Financing the Project :-

12) Type of Offer Required :- Budget + Firm (Feasibility Study / Indicative / Budget / Firm)

13) Cost of existing Power

(a) From Grid including Maximum. Demand Charges :- @ Rs. 4.4 per Unit

(b) Generated from other source :-

(DG / TG etc.)

Additional Information :-

Max Demand Charges Rs. 350 per KVA

Rate Rs. 2.85 per Unit

Other Charges Rs. 1.0 Per Unit

Avg. Unit Charge Rs. 4.4 per Unit

Avg. Consumption 1250000 units per month



Statement: Any reference to the OEM, part number or other OEM information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.

All the brands and trademarks in the whole domain of the website belong to their own owners and does not mean that we are their authorized partner or dealer. All the information in this website is only for reference, we do not assure its accuracy.

This statement supersedes all other claims and statements on all pages, files, pics and information within this whole web domain.
Copyright©2006-2019 Leda Greenpower Beijing ICP Reg. No: 10010978.   Fax:0086-10-84161062  E-mail: