3. Basic Design Data
3.1 Project location
Elevation of the plant site is about 1500 m.
3.2 Geothermal source information
Steam at outlet of separators:
NCG 3.0%
Silica: <5 ppm
Dryness >99%
TDS (total dissolves solids): 20-60 ppm
Max. steam flow at outlet of steam header: 115.1 t/h
Interface Steam Pressure 8.6 bara
3.3 Climate data
Process Design Dry Bulb Temperature, annual average18.8oC, 90% occurrence level = 19.5oC at Candikuning
Equipment Design Temperature Range -5oC to 40oC Design Wind Speed 35 m/s
Design Seismic Zone UBC 4 (vendor A) Design Rainfall Candikuning Station: 2,512 mm/year
3.4 HV connection
20K/50Hz Single circuit
|