No. |
Equipment Name |
The parameters |
CIF Unit Price (USD) |
Qty. |
CIF Subtotal (USD) |
Origin |
I. Imported Engine -Generator Set (Main Body) |
1 |
CAT G3516H Genset |
2000kw, 11kV, 50Hz, 0.8pf |
$975,652.70 |
6 |
$5,853,916.20 |
U.S.A |
2 |
One year parts |
8000hrs maintenance parts |
$17,600.00 |
6 |
$105,600.00 |
U.S.A |
3 |
Tools-G3516H |
general & speical tools |
$5,500.00 |
1 |
$5,500.00 |
U.S.A |
/DIV> |
Total Price (Imported Portion) -CIF Brisbane, Australia: |
$5,965,016.20 |
/DIV> |
No. |
Equipment Name |
The parameters |
EXW Unit Price (USD) |
Qty. |
EXW Subtotal (USD) |
Origin |
II. Domestic Sourced Engine Auxiliaries |
1 |
Genset Parallel Control System |
800×600×2100,RAL7035 |
$54,918.03 |
6 |
$329,508.20 |
China |
2 |
gas train |
DN80 - DN 100 |
$10,163.93 |
6 |
$60,983.61 |
Sino-Italy JV |
3 |
Exhaust Mufflers |
45 dBA, spark-arrested |
$6,852.46 |
6 |
$41,114.75 |
China |
4 |
Remote Radiator |
Designed for G3516H |
$42,295.08 |
6 |
$253,770.49 |
China |
5 |
Other auxiliaries |
battery chargers, flexibles etc. |
$11,147.54 |
6 |
$66,885.25 |
China |
6 |
Genset Container |
13m * 3.3m * 3m |
$98,360.66 |
6 |
$590,163.93 |
China |
/DIV> |
Total Price (Domestic Sourced Portion) -Ex-works: |
$1,342,426.23 |
/DIV> |
Notes |
/DIV> |
/DIV> |
/DIV> |
/DIV> |
/DIV> |
/DIV> |
1. For imported price in USD are based on CIF Brisbane, Australia & incl. initial fill-in lube oil. |
2. Domestic sourced price are based on EX-Works delivery. |
3. The above prices shall be valid for 60 days only. |
4. The above prices are based on product warranty of 12 months after commissioing & acceptance on site. |
5. Payment terms: Imported value shall be based on 100% L/C; Domestic sourced value shall be based on 30% advance payment upon signing contract, 50% upon ex-works delivery, 15% upon installation & 5% upon commerical operation. |
Our ref. 10/6.120140513 |
G3516H |
V16 |
Power |
2027 KW |
Electrical Efficiency |
Up to 44.7% |
Thermal Efficiency |
Up to 43.1% |
Oil Consumption |
182 mg/kWh |
Major Overhaul |
80,000 h |
Transient Load Steps |
Up to 25% of rated |
G3516H HR Configuration Transient Performance Engine Class Definition The information contained herein applies only to the Cat® G3516H Performance Configuration Gas engines equipped with the ADEM™ IV Control System. Island mode operation as defined by Caterpillar is any Gas Generator Set operation that is not paralleled to a public utility. In this operational state the Gas Engine must maintain torque and crankshaft speed (bus frequency) during steady state operation. The generator voltage is maintained using a voltage regulator. In Island Mode operation, increases in load cause the engine speed to decrease below the rated speed of the engine and then recover back to the rated speed after a period of time. Decreases in load cause the inverse. The shape of the engine speed response or generator set frequency response to an application of load is generally a function of the amount of load being added or removed, as well as, the settings of the generator voltage regulator, speed governor gain settings, ambient conditions, fuel quality, and fuel characteristics. Engine Ratings Engine ratings are at standard conditions. Refer to TMI web for additional conditions and information for site-specific gas engine ratings. • G3516H HR Configuration with and without engine driven pumps Transient Performance The transient performance of the G3516H Performance Configuration is given below, in loading and unloading diagrams for varying load step sizes, with corresponding response envelopes. Block Load and Unload Diagrams for 500 mg/Nm3 (1.0 g/bhp-hr) NOx Setting Block load/unload diagrams are provided to give information about the permissible load increases or decreases in effective power that can be obtained from a given percent of the rated effective electrical power output of the generator set (Pel, in or Pel, de). Maximum loading and unloading diagrams are given last. The steady state (SS) for frequency is required to be ± 1.25% of nominal Frequency. Frequency recovery time is given to ±1.75% of rated Frequency. The steady state for Voltage is required to be ± 5%. The steady state values assume a load fluctuation less than or equal to 1.5% over 60 seconds. The package is capable of Class G1 load steps (up and down) up to 15% steps. |