5.6 Exhaust Gas Boiler
Model |
LFL67-0.7 |
Rate steam capacity: |
700kg/H |
Quantity |
2 sets |
Steam pressure: |
7Bar |
Steam temperature |
170°C |
Safe pressure |
0.75Mpa |
Heating area |
67m2 |
Boiler back pressue |
Max. 220pa |
Waste gas inlet temperature |
350°C |
Waste gas outlet temperature |
200°C |
Overall dimensions LxWxH |
1824x2310x5318mm |
Weight |
5000kg |
Manufacturer |
Ning Dong |
5.7 Air compressor
Model |
CZ-20/30F |
Type |
Single row vertical, differential piston two-stage compression, air cooled |
Exhaust capacity |
Min. 20m3/h |
Quantity |
3 sets |
Rating pressure |
3MPa |
Cylinder bore |
1st stage: 102mm, 2nd stage: 90mm |
Piston stroke |
65mm |
Exhaust temperature |
Max. 85°C |
Rotary speed |
1000r/min |
Shaft power |
<5kW |
Motor |
Y132S-6/5.5kW |
Overall dimensions |
970x440x700mm |
Weight |
155kg |
Manufacturer |
Ning Dong |
5.8 Air Bottle
Model |
B500 |
Quantity |
4 sets |
Air inlet & outlet |
�?/FONT>33 |
Working pressure |
2.94Mpa |
Volume |
500L |
Overall dimensions |
�?/FONT>628x2305mm |
Weight |
468kg |
Manufacturer |
Ning Dong |
5.9 Cooling tower
Model |
GBL-100 |
Quantity |
4 sets |
Cooling capacity |
100M3/H |
Inlet water pressure |
34 kpa |
Temperature reduce |
5-10°C |
Fan power |
5Kw |
Net weight |
1800kg |
Manufacturer |
Zhejiang Lianfeng Co., Ltd. |
5.10 S9-250/6/0.4 Station transformer
5.11 HFO unloading pump station
Type |
HFO58 |
Quantity |
1 set |
Capacity |
58M3/h |
Outlet pressure |
0.28Mpa |
Motor power |
18.5Kwx2 |
Manufacturer |
Ning Dong |
5.12 Diesel oil unloading pump station
Type |
DO58 |
Quantity |
1 set |
Capacity |
58M3/h |
Outlet pressure |
0.28Mpa |
Motor power |
18.5kWx2 |
Manufacturer |
Ning Dong |
5.13 Station batteries and battery charger panel
Model |
PGD7-IV-180-220 |
AC input voltage |
400Vac±20% |
DC output voltage |
24V, 220V |
DC output current |
A |
Storage battery capacity |
60Ah for 24VDC, 30Ah for 220VDC |
Accuracy of voltage regulation |
Max. ±0.2% |
Accuracy of current regulation |
Max. ±0.2% |
Ripple factor |
Max. 0.1% |
Power factor |
Min. 0.93 |
Efficiency |
Min. 95% |
Noise |
50dB |
Dielectric strength |
2000V 1 min without breakdown |
Operation environment |
Temperatur:-10 to 45°C, Relative humidity : not greater than 90% at 20±5°C |
Interface |
RS485, RS232 & RS422 |
High frequency rectifier module |
Emerson HD22020 3pcs |
PLC |
SIEMENS S7-200 |
LCD display screen |
HITECH PWS 5.7" |
Rectifier module |
Emerson HD2205 3pcs |
Maintenance-free lead-acid battery |
A400-180/12V 18 pcs |
Overall dimensions (LxDxH) |
800x800x2200mm 3pcs |
Manufacturer |
Zhejiang Sanchen Electrical Co. Ltd. |
5.14 Heavy Fuel Oil storage
Model |
STH600 |
Quantity |
1 unit |
Diameter |
�?/FONT>9.55m |
Bottom material |
MS Plate 12mm |
Shell material |
MS Plate 12mm & 10mm & 8mm |
Roof material |
MS Plate 6mm |
Volume |
600M3 |
Steam coil pipe(seamless pipe) |
DN50 |
Heat-exchange area |
20M2 |
Manhole Diameter |
�?/FONT>500 |
Level indicator |
1 unit |
Oil inlet (seamless pipe) |
ND100 |
Oil outlet (seamless pipe) |
ND80 |
Overflow (seamless pipe) |
ND100 |
Drain (seamless pipe ) |
ND50 |
Dimension |
�?/FONT>9.55 x 9m |
Manufacturer |
Provided by customer |
5.15 Diesel Oil Storage
Type |
STD200 |
Quantity |
1 unit |
Diameter |
�?/FONT>5.9m |
Bottom material |
MS Plate 10mm |
Shell material |
MS Plate 10mm & 8mm & 6mm |
Roof material |
MS Plate 6mm |
Volume |
200M3 |
Manhole Diameter |
�?/FONT>500 |
Level indicator |
1 unit |
Oil inlet (seamless pipe) |
DN80 |
Oil outlet (seamless pipe) |
DN80 |
Overflow (seamless pipe) |
DN80 |
Drain (seamless pipe) |
DN50 |
Dimension |
�?/FONT>5.9m x 7.5m |
Manufacturer |
Provided by customer |
5.16 Buffer HFO Tank:
Type |
STH50 |
Quantity |
2 units |
Diameter |
�?/FONT>3.82m |
Bottom material |
MS Plate 6mm |
Shell material |
MS Plate 6mm & 5mm & 4mm |
Roof material |
MS Plate 4mm |
Volume |
50M3 |
Manhole Diameter |
�?/FONT>450 |
Level indicator |
1 unit |
Steam coil pipe(seamless pipe) |
DN25 |
Oil inlet (seamless pipe) |
DN80 |
Oil outlet (seamless pipe) |
DN80 |
Drain (seamless pipe) |
DN40 |
Overflow Pipe (seamless pipe) |
DN50 |
Heat-exchange area |
6.5M2 |
Dimension |
�?/FONT>3.82m x 4.50m |
Manufacturer |
Provided by customer |
5.17 Daily Heavy Fuel Oil Tank
Type |
STH20 |
Quantity |
1 unit |
Diameter |
�?/FONT>2.4m |
Bottom material |
MS Plate 6mm |
Shell material |
MS Plate 6mm & 5mm & 4mm |
Roof material |
MS Plate 4mm |
Volume |
20M3 |
Manhole Diameter |
�?/FONT>450 |
Level indicator |
1 unit |
Steam coil pipe(seamless pipe) |
DN25 |
Oil inlet (seamless pipe) |
DN80 |
Oil outlet (seamless pipe) |
DN80 |
Drain (seamless pipe) |
DN40 |
Overflow Pipe (seamless pipe) |
DN50 |
Heat-exchange area |
6.5M2 |
Dimension |
�?/FONT>2.4m x 5m |
Manufacturer |
Provided by customer |
5.18 Daily Diesel Oil Tank
Type |
STD20 |
Quantity |
1 unit |
Diameter |
�?/FONT>2.4m |
Bottom material |
MS Plate 6mm |
Shell material |
MS Plate 6mm & 5mm & 4mm |
Roof material |
MS Plate 4mm |
Volume |
20M3 |
Manhole Diameter |
�?/FONT>450 |
Level indicator |
1 unit |
Oil inlet (seamless pipe) |
DN80 |
Oil outlet (seamless pipe) |
DN80 |
Overflow (seamless pipe) |
DN50 |
Drain (seamless pipe) |
DN40 |
Dimension |
�?/FONT>2.4m x 5m |
Manufacturer |
Provided by customer |
5.19 Residual Oil Tank
Type |
STH20 |
Quantity |
1 unit |
Diameter |
�?/FONT>2.4m |
Bottom material |
MS Plate 6mm |
Shell material |
MS Plate 6mm & 5mm & 4mm |
Roof material |
MS Plate 4mm |
Volume |
20M3 |
Manhole Diameter, P> |
�?/FONT>450 |
Level indicator |
1 unit |
Oil inlet (seamless pipe) |
DN80 |
Oil outlet (seamless pipe) |
DN80 |
Overflow (seamless pipe) |
DN50 |
Drain (seamless pipe) |
DN40 |
Dimension |
�?/FONT>2.4m x 5m |
Manufacturer |
Provided by customer |