Westinghouse/ABB MMZZ5Z3ZG1 spare parts
Brand |
Part number |
Description |
Westinghouse |
1163801 |
MG-6 Type, 6 Pole, 125VDC, Self Reset, Non-Adjustable Pickup, Modled Base without Cover, Front Connected, Auxiliary Relay |
Westinghouse |
1875524 |
CV-7 Type, Over Voltage Relay, Circuit Voltage: 0.2-2.0 Amp DC, 55-140 Volt Adjustable Range |
Westinghouse |
1878176 |
DGF Type, Field Ground Detection Relay |
Westinghouse |
1962181 |
KO-3 Type, Carrier Use, High Speed Over-current Relay |
Westinghouse |
1875240-A |
CO-5 Type, Long time, Hi-Lo, 60HZ, Non-directional, Single Phase, Time Overcurrent Relay. Reference: 41-101 |
Westinghouse |
1875240-A |
CO-5 Type Non-directional, Single Phase, Time Overcurrent Relay. |
Westinghouse |
1875506A |
CV-1 Type, Single Phase, 120VAC, 0.2-2 Amps, 60Hz, Long Time Undervoltage Relay |
Westinghouse |
1956071A |
ITH Type, High Dropout Instantaneous Relay |
Westinghouse |
288B714A28A |
ITH Type, High Dropout Instantaneous Relay. |
Westinghouse |
290B038A09A |
Westinghouse CRN-1 Reverse Power Relay Style # 290B038A09A |
Westinghouse |
290B346A21B |
HU Type, 2.9-8.7A Taps, .3 x Tap Pickup, Inst. Trip 10x Tap Amps, 0.2-2A Indicating Contactor Unit, Transformer Differential Relay. |
Westinghouse |
293B146A09 |
CVQ Type, 55-140 Adjustable Voltage Range, 5%-10% Adjustable Sensitivity, 0.2/2.0 ICS, Negative Sequence Overvoltage Relay |
Westinghouse |
KO-1 Retrofit |
KO-1 Type, High Speed Over-current Relay. |
Westinghouse |
KO-4 Retrofit |
KO-4 Type Retrofitted with KC-4 Relay. KC-4 is a Non-Directional, Overcurrent relay. |
Westinghouse |
S-1303508 A |
115VDC, Contactor Coil. |
Westinghouse |
COH-1271471 |
Westinghouse COH Relay Style No: 1271471 (Relay and Cover Only) |
Westinghouse/ABB |
1163802 |
MG-6 Type, 115VAC, 60 Hz, Multi-contact, Auxiliary Relay |
Westinghouse/ABB |
1163803 |
MG-6 Type, 115VAC, 60 Hz, Multi-contact, Auxiliary Relay |
Westinghouse/ABB |
1271901 |
BL-1 Type, 2.5-5A, 0.2-2.0A Indicating Contactor Unit, Thermal Overload Relay. Ref.: 41-553.2B. |
Westinghouse/ABB |
1545028 |
CO-8 Type, Inverse, Single Phase, Non-Directional, Overcurrent Relay |
Westinghouse/ABB |
1861198 |
CO-9 Type, Single Phase, Very Inverse, 4-12A Time Unit, 3A Indicating Contactor Switch, SPST-CO, Non-Torque Controlled, Non-Directional, Overcurrent Relay. Ref.: 183A054 |
Westinghouse/ABB |
1875240 |
CO-5 Type, Long time, Hi-Lo, 60HZ, Non-directional, Single Phase, Time Overcurrent Relay. Reference: 41-101 |
Westinghouse/ABB |
1875265 |
CO-8 Type, Single Phase, Inverse, 0.5-2.5A Timing Unit, 0.2/2.0A Indicating Contactor Switch, SPST, Time Overcurrent Relay |
Westinghouse/ABB |
1875289 |
CO-9 HILO Type, Single Phase, Very Inverse, 1-12 Time Unit, 6-144 Instantaneous Unit, 0.2/2.0A DC Indicating Contactor Switch Unit, SPST, Non-Torque Controlled, Non-Directional Overcurrent Relay. Ref. 3498A02. |
Westinghouse/ABB |
1875516 |
CV-2 Type, Single Phase, Short Time, 120VAC, 55-140 Adjustable Range, 0.2/2.0A DC Indicating Contactor Switch, DPST-CC, Non-Directional Undervoltage Relay. Ref. 182A725 |
Westinghouse/ABB |
1875556 |
CR-6 Type, Definite Time, 132VAC, 60HZ, 4-12A Time Unit, Overcurrent, Directional, Single Phase, Voltage Polarized Phase Relay. Reference: 41-131E |
Westinghouse/ABB |
1875576 |
CRP-8 Type, Single Phase, Inverse Time, 208V/30 Second Voltage Polarized, 0.2/2.0A Indicating Contactor Switch, 0.5-2.5A Time Unit, 10-40A Instantaneous Unit, Ground Fault Protection, Directional Overcurrent Relay |
Westinghouse/ABB |
1876047 |
SC Type, Instantaneous, 1-4A Adjustable Range, 85-98% AC Dropout Ratio, 65-80% DC Dropout Ratio, 2 NO Contacts, Mechanical Operation Indicator, FT-21 Flexitest Case, Overcurrent Relay. Ref.: 182A854. |
Westinghouse/ABB |
1876048 |
SC Type, Single Unit, 2-8A Adjustable Range, 85-98% AC Dropout Ratio, 65-80% DC Dropout Ratio, 25-60Hz, Motor Operation Indicator, 2NO Contacts, Flexitest Case, Instantaneous Overcurrent Relay. Ref.: 182A854. |
Westinghouse/ABB |
1876062 |
SC-1 Type, Single Unit, 0.5-2.0A Adjustable Range, 35-60% AC Dropout Ratio, 25-40% Dropout Ratio, DC or 25-60Hz Mechanical Operation Indicator, Self-Reset, FT-21 Case, Current Operated, Instantaneous Relay. Ref.: 182A854 |
Westinghouse/ABB |
1876094 |
SV Type, 60HZ, Single Unit, 2 NO., Instantaneous Adjustable Voltage Relay. Reference: 41-227E. |
Westinghouse/ABB |
1876163 |
HA Type, 5A, Perentage Differential Relay |
Westinghouse/ABB |
1876244 |
COV-8 Type, Inverse, Single Phase, 80-100VAC, 0.2/2.0A Indicator Contact Switch, 4-12 Time Unit, Overcurrent Voltage Controlled Relay |
Westinghouse/ABB |
1876254 |
CO-9 Type, Single Phase, Very Inverse, 4-12A Time Unit, 3A Indicating Contactor Switch, SPST-CO, Non-Torque Controlled, Non-Directional, Overcurrent Relay. Ref.: 183A054 |
Westinghouse/ABB |
1876824 |
CRD-9 Type, Single Phase, Directional, Very Inverse, 280V/30sec, 230A/1sec, 2-6 Time Unit, 0.2/2.0 Indicating Contactor Switch, SPST-CC, Ground Fault Protection Overcurrent Relay. Ref.: 57D4561. |
Westinghouse/ABB |
1878395 |
SC Type, (3) Units per Case, 2-8A Adjustable Range, 85-98% AC Dropout Ratio, 65-80% DC Dropout Ratio, Mechanical Operation Indicator, 2 NO, Flexitest Case Type, Overcurrent Relay |
Westinghouse/ABB |
1878496 |
COV-6, Single Phase, Definite Time, 80-100VAC Adjustable Voltage, 4-12A Time Unit, 0.2/2.0A Indicating Contactor Switch, Voltage Controlled, Non-Directional, Overcurrent Relay |
Westinghouse/ABB |
1878509 |
COV-7 Type, Single Phase, Moderately Inverse, 80-100VAC Adjustable Voltage, 2-6 Time Unit, 10-40 Instantaneous Trip Unit, 0.2/2.0A DC Indicating Contactor Switch, SPST, Non-Directional, Voltage Controlled Overcurrent Relay. Ref.: 183A048. |
Westinghouse/ABB |
1878517 |
COV-8 Type, 120V, 60Hz, 2-6 Overcurrent, Inverse Time, Voltage Controlled Relay. Reference: 41-116.1C |
Westinghouse/ABB |
1955361 |
H3 Type, Three Phase, Line Protection, I leads V by 45degrees, 5A, 120V, 1.0A DC Operation Indicator and Contactor Switch, Directional, Power Flow Relay. Ref.: 183A335. |
Westinghouse/ABB |
1956074 |
ITH Type, High Dropout Instantaneous Relay. Reference: 41-771G |
Westinghouse/ABB |
1956207 |
COQ Type, 3-5A AC Time Unit, 0.2/2.0A DC Indicating Contactor Switch, Negative Sequence Relay, Ref.: 182A973. |
Westinghouse/ABB |
1963847 |
CVQ Type, 55-140V Adj Range, 5-10% Adjustable Sensitivity, 1.0A AC Indicating Contactor Switch, SPDT-CC Instantaneous Negative Sequence Overvoltage and Inverse Time Delay Undervoltage Relay. Ref.: 188A644. |
Westinghouse/ABB |
1155689A |
SG Type, 125VDC, Double Pole, Self Reset, Surface Mount, Rear Connected, Solid Style Cover, Auxiliary Relay. Reference: 41-817E |
Westinghouse/ABB |
1161540E |
SG Type, 125VDC, Self-Rest, Non Adjustable Pickup, DPDT, 2NC/2NO Contacts, Front Connected Auxiliary Relay |
Westinghouse/ABB |
1271007A |
CA Type, Single Phase, 5A, 25-60Hz, 10% Sensitivity, Percentage Differential Relay for Generator Protection. Ref.: 41322.2F |
Westinghouse/ABB |
1293C47G04 |
GF Type, Class I, 120 VAC Control Power, 10-60A Instantaneous Unit, 100-1200A Pick Up, Ground Fault Relay. |
Westinghouse/ABB |
129A501G01 |
FT-1 Test Switch 129A501G01 |
Westinghouse/ABB |
129A518G01B |
FT-1 Test Switch 129518G01B |
Westinghouse/ABB |
129A539G01 |
FT-1 Type, 10 Potentials, Screw Terminals, Standard Depth, Stand Alone 10 Pole Flexitest Switch |
Westinghouse/ABB |
12IJF51A11A |
IJF Type, 115V, 60hz, Frequency Relay |
Westinghouse/ABB |
12IJF51A1A |
IJF Type, 115V, 60hz, Frequency Relay |
Westinghouse/ABB |
1338954A |
CO Type, Single Phase, Definite Time, 4-15A Time Unit, 10-40A Instantaneous Unit, 2 Sec. Delay, 2A Contactor Switch, 1A Indicator Switch, Time Overcurrent Relay |
Westinghouse/ABB |
1338956-A |
CO Type, Single Phase, Definite Time, 2 Seconds, 4-15A, 20-80A Instantaneous Unit, 0.2A Indicator Coils, 2A Contactor Switch, SPST, Overcurrent Relay. |
Westinghouse/ABB |
1338D10A01 |
CA(1E) Type, 25-60Hz, 5A, 10% Sensitivity, 1.0 Indicating Contactor Switch, SPST-CC Contacts, Generator Relay. Ref.: 3525A50 |
Westinghouse/ABB |
1346D96A02 |
SKD-T Type, Solid StateThree Phase, 5A, 120V, 60Hz, 125VDC Instantaneous Unit, 0.2/2.0 Indicating Contactor Unit, Single Zone with Output Contact, Distance Relay. Ref.: 41-495.51. |
Westinghouse/ABB |
1351D17A01 |
IT Type, Single Phase, 0.15-0.30A Current Range, 0.2/2.0 Indicating Contactor Switch, DPST-CC, Overcurrent Instantaneous Relay. Ref.: 9640A39. |
Westinghouse/ABB |
1356D35A03 |
CVX-1 Type, Bus & Line, 120VAC, 48/125/250VDC, 0.2/2.0A Indicating Contactor Unit, SPST, 20-60 egrees Calibration, Separate Outputs for HLDB & HBDL - Isolate Potential Coils, Synchronism Verifier Relay. Ref.: 9654A73 & 9654A95. |
Westinghouse/ABB |
1545026A |
CO-8 Type, Inverse Time, Single Phase, 0.2/2.0A Indicating Contactor Switch, SPST, Torque Controlled, Time Overcurrent Relay |
Westinghouse/ABB |
1545029A |
CO Type, Inverse Curve, 4-12A, 10-40 Instantaneous, 1A Indicator, Overcurrent Relay. |
Westinghouse/ABB |
1678791A |
CV-7 Type, Short Time, Single Phase, 0.2/2.0A Indicating Contactor Switch, SPDT, Over/Undervoltage Relay |
Westinghouse/ABB |
183A205A15 |
CV-8 Type, Single Phase, Short Time, 67VAC Nominal, 5.4-20VAC Adjustable Range, 0.2/2.0 Indicating Contactor Switch, Non-Directional, Overvoltage Relay. Ref.: 185A038. |
Westinghouse/ABB |
1875241A |
CO-5 Type, Long time, Hi-Lo, 60HZ, Non-directional, Single Phase, Time Overcurrent Relay. Reference: 41-101 |
Westinghouse/ABB |
1875244A |
CO-6 Type, Single Trip, Definite Minimum Time, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
1875266A |
CO-8 Type, HILO, Inverse Time, Single Phase, 1-12A Time Unit, 6-144A Instantaneous Unit, 0.2/2.0A Indicating Contactor Switch, SPST, Non-Directional, Non-Torque Controlled, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
1875267A |
CO-8 Type, Single Phase, Inverse, 1012sec Time Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, Non-Torque Controlled, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
1875273A |
CO-8 Type, Single Phase, Inverse, 2-6A Time Unit, 10-40A Instantaneous Unit, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Torque Controlled, Non-Directional, Overcurrent Relay |
Westinghouse/ABB |
1875275A |
CO-8 Type, Single Phase, Inverse, 4-12A Overcurrent Unit, 10-40A Instantaneous Trip Unit, 0.2-2.0A Indicator, Long Time Overcurrent Relay |
Westinghouse/ABB |
1875282A |
CO-9 Type, Single Phase, Very Inverse, 0.5-2.5A Time, 4-16A Instantaneous, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, HILO, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875286A |
CO-9 Type, HILO, Very Inverse, Single Phase, 1-12A Time Unit, 6-144A Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875289A |
CO-9 Type, Single Phase, Very Inverse, 1-12A Time, 6-144A Instantaneous, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, HILO, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875291A |
CO-11 Type, Extremely Inverse, Single Phase, Non-directional, 60HZ, Torque Controlled, .2/2.0A IDC, 0.5-2.5 Range, FT-11 Case, Overcurrent Relay. For use with feeder circuit breakers Reference: 41-101E |
Westinghouse/ABB |
1875295A |
CO-11 Type, Extremely Inverse, Single Phase, 0.5-2.5A Time Unit, 4-16A Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, HILO, Non-Torque Controlled, Non-Directional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875299A |
CO-11 Type, Extremely Inverse, Single Phase, Non-directional Motor/Time Overcurrent Relay. Reference: 41-101U |
Westinghouse/ABB |
1875301A |
CO-11 Type, Extremely Inverse, Single Phase, 1-12A Time Unit, 6-144A Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, HILO, Non-Torque Controlled, Non-Directional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875302A |
CO-11 Type, HILO, Extremely Inverse, Single Phase, .5-2.5A Time Unit, 6-144A Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Nondirectional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
1875508A |
CV-2 Type, Single Phase, Short Time, 120VAC, 55-140 Adjustable Range, 0.2/2.0A DC Indicating Contactor Switch, SPST-CC, Non-Directional Undervoltage Relay. Ref. 182A724 |
Westinghouse/ABB |
1875509A |
CV-2 Type, Single Phase, Short Time, 240VAC, 110-280 Adjustable Range, 0.2/2.0A DC Indicating Contactor Switch, SPST-CC, Non-Directional Undervoltage Relay. Ref. 182A724 |
Westinghouse/ABB |
1875516A |
CV-2 Type, Single Phase, Short Time, 120VAC, 55-140 Adjustable Range, 0.2/2.0A DC Indicating Contactor Switch, DPST-CC, Non-Directional Undervoltage Relay. Ref. 182A725 |
Westinghouse/ABB |
1875527A |
CV-8 Type, Low Pickup/Harmonic Filter Capable, Generator Ground Protection Relay. Reference: 41-222E |
Westinghouse/ABB |
1955332A |
CV-7 Type, Single Phase, 120VAC, 0.2-2.0A ICS, 60HZ, 55-140 Range, Short Time Over/Undervoltage Relay. Reference: 41-201M |
Westinghouse/ABB |
1956085A |
COV-11 Type, Single Phase, Extremely Inverse, 4-12A Time Unit, 80-100VAC, 0.2/2.0 Indicating Contactor Switch, SPST, Voltage Controlled, Non Directional, Overcurrent Relay. Ref.: 183A047. |
Westinghouse/ABB |
219M2500 |
87M Type, Three Phase, Circuit Shield, Solid State, 48/100VDC, 0.1-5.0A Sensitivity, 50/60Hz, Machine Application, Non Linear Slope, Percentage Differential Relay |
Westinghouse/ABB |
223S1140 |
51I Type, Single Phase, Circuit Shield, Solid State, Inverse, 125VDC, 0.5-2.0A Time Pickup Unit, 50/60Hz, Time Overcurrent Relay. |
Westinghouse/ABB |
223S1243 |
51I Type, Single Phase, Solid State, Circuit Shield, Inverse, 1.5-6A Time Unit, 1.4-5.6A Instantaneous Unit (In Multiples of Tap Setting), 125VDC, Thyristor Output, Time Overcurrent Relay. |
Westinghouse/ABB |
223T2141 |
51Y Type, Solid State, Circuit Shield, Three & Single Phase, Very Inverse, 0.5-2A Time Unit Pick Up Range, 2-20 Instantaneous Attachment, Thyristor Output, Time Overcurrent Relay. |
Westinghouse/ABB |
223T2211 |
51Y Type, Circuit Shield, Solid State, Three Phase, Very Inverse, 1.5-6A Time Unit, 2-20A Instantaneous Unit, Time Overcurrent Relay. |
Westinghouse/ABB |
223T3221 |
51E Type, Solid State, Circuit Shield, Extremely Inverse, 350 VDC, 1-10 TOC, 2-20 Instantaneous, 50/60Hz, Overcurrent Relay. |
Westinghouse/ABB |
231A0010 |
76T Type, Circuit Shield, Solid State, DC Overcurrent Relay |
Westinghouse/ABB |
246C715G01 |
D4B-2F Type, (2) Stators, 120V, 2.5 Amps, 60HZ, 3 Watt, FT-21 Flexitest Case, Switchboard Watthour Meter. See Notes for Details. Reference: I.L. 42-227 |
Westinghouse/ABB |
264C897A07 |
CO-5 Type, Single Phase, 1-12A Time Unit, 6-144A Instantneous Unit, 0.2/2.0A Indicating Contactor Switch, SPST, HILO, Very Inverse Time, Non-Directional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
264C897A07 |
CO-5 Type, Long Time, HI-LO, 1-12 Time Unit, 6-144 Instantaneous Unit, 60HZ, Non-directional, Single Phase, Time Overcurrent Relay. Reference: 41-102E |
Westinghouse/ABB |
264C898A01 |
CO-6 HILO Type, Non-Directional, Single Phase, 0.5-2.5 Time Unit, 6-144 Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
264C898A03 |
CO-6 Type, Definite Time, HI-LO, Single Phase, .5-2.5 Time Unit, 2-48 Instantaneous Unit, 60HZ, SPST, Non-directional, Overcurrent Relay. Ref.: 3498A02 |
Westinghouse/ABB |
264C898A07 |
CO-6 Type, Single Trip, Definite Minimum Time, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C899A01 |
CO-7 Type, Single Phase, HILO, Moderately Inverse, 0.5-2.5A Time Unit, 0.2/2.0A Indicating Contactor Switch, SPST, Non-Directional, Non-Torque Controlled, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
264C900A01 |
CO-8 Type, Single Trip, Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C900A02 |
CO-8 Type, Double Trip, Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C900A03 |
CO-8 Type, Single Trip, Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C900A05 |
CO-8 Type, Single Phase, 1-12A Time Unit, 0.2/2.0A Indicating Contactor Switch, SPST, HILO, InverseTime, Non-Directional, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
264C900A06 |
CO-8 Type, Double Trip, Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C900A07 |
CO-8 Type, Single Phase, Inverse, 1-12 Time Unit, 6-144 Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, Non-Torque Controlled, HILO, Time Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
264C900A07 |
CO-8 Type, Single Trip, Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C900A11 |
CO-8 Type, Single Phase, Inverse, 1-12 Time Unit, 2-48 Instantaneous Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Non-Directional, Non-Torque Controlled, HILO, Time Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
264C901A01 |
CO-9 Type, Hi-Lo, Single Phase, Very Inverse, Non-Directional Time Overcurrent Relay, SPST, 0.2/2.0 ICS, 0.5-2.5 Time Unit |
Westinghouse/ABB |
264C901A02 |
CO-9 Type, HILO, Single Phase, Very Inverse, 0.5-2.5A Time Unit, DPST, Non-Directional, Overcurrent Relay |
Westinghouse/ABB |
264C901A03 |
CO-9 Type, Single Phase, 0.5-2.5A Time Unit, 2-48A Instantneous Unit, 0.2/2.0A Indicating Contactor Switch, SPST, HILO, Short Time, Non-Directional, Overcurrent Relay. Ref.: 3498A02. |
Westinghouse/ABB |
264C901A03 |
CO-9 Type, Single Trip, Very Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C901A05 |
CO-9 Type, Single Phase, 1-12A Time Unit, 0.2/2.0A Indicating Contactor Switch, SPST, HILO, Very InverseTime, Non-Directional, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
264C901A05 |
CO-9 Type, Single Trip, Very Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C901A06 |
CO-9 Type, Double Trip, Very Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C901A07 |
CO-9 Type, Single Trip, Very Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C901A08 |
CO-9 Type, Double Trip, Very Inverse, Non-Directional, Single Phase, Hi-Lo Over-current Relay |
Westinghouse/ABB |
264C901A09 |
CO-9 Type, HILO, Very inverse Time, .5-2/5 Time Unit, 6-144 Inst. Unit, .2/2.0A, SPST |
Westinghouse/ABB |
264C901A27 |
CO-9HILO Relay, Commercial Grade, Overcurrent, Non-Torque Controlled, Very Inverse Time, SPST, 1-12Aac, 50Hz, 6-144Aac IIT, .2/2Adc ICS, FT-11 Case, IS 3498A02, DB41-102E, IL41-100, Weight lbs(kg): 12(6) Dimension in(mm): 12(305)x15(381)x12(305) |
Westinghouse/ABB |
265C047A05 |
CO-11 Type, Hi-Lo, Single Phase, Extremely Inverse, Non-Directional Time Overcurrent Relay, SPST, 0.2/2.0 ADC, 0.5-2.5 Time Unit |
Westinghouse/ABB |
265C047A07 |
CO-11 Type, Extremely Inverse, Single Phase, Non-directional Time Overcurrent Relay. |
Westinghouse/ABB |
265C195A05 |
CO-2 Type, Single Phase, 1-12A Time Unit, 0.2/2.0A Indicating Contactor Switch, SPST, HILO, Short Time, Non-Directional, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
288B563A24 |
CR-6 Type, Definite Time, 0.2-2A Indicator, 60HZ, 2-6A Time Unit, Overcurrent, Directional, Single Phase, Phase Fault Detection, Voltage Polarized Phase Relay. Reference: 41-131E |
Westinghouse/ABB |
288B574A22 |
CR-8 Type, 120V, 4-12A Overcurrent Unit, 0.2/2.0A Indicating Contactor Switch, Directional Overcurrent Relay. Ref.: 41-131. |
Westinghouse/ABB |
288B576A11 |
CR-9 Type, 240V, 2-6A Overcurrent Unit, 0.2/2.0A Indicating Contactor Switch, Directional Overcurrent Relay. Ref.: 41-131. |
Westinghouse/ABB |
288B618A12A |
CV-8 Type, Short Time, Single Phase, 199VAC Nominal, 16-40VAC Adjustable, 8% Pickup, 0.2/2.0 Indicating Contactor Switch, SPST-CC, Non Directional Overvoltage Relay. Ref.: 188A307. |
Westinghouse/ABB |
288B714A31 |
ITH Type, 3 ITH Units/Case, 0.5-1.0A, (3) 1.0A Operation Indicator, 0.2A Seal In Contactor Switch, DPST, Overcurrent Instantaneous Relay. Ref.: 183A128. |
Westinghouse/ABB |
288B717A13 |
CO-8 Type, Single Phase, Inverse, 0.5-2.5A Time Unit, 2-8A Instantaneous Unit, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Non-Directional, Overcurrent Relay. |
Westinghouse/ABB |
288B868A19 |
D-3 Type, High Contact Capacity, 0-200 millivolts, 48VDC, Over-Under Current/Volts Relay. |
Westinghouse/ABB |
289B142A09 |
KD Type, 5 Amp, 120V, 60CY, 3-Phase, Compensator Distance Relay, Complex. Reference: IL-41-498-5 |
Westinghouse/ABB |
289B142A09 - RC |
Services to test and reconditioned customer supplied Westinghouse KD relay. See notes for details. |
Westinghouse/ABB |
289B355A11 |
COM-5 Type, Single Phase, Long Time, 2-6A Time Unit, 10-40A IIT Unit, 4-8A ITH Unit, (2) 0.2/2.0A Indicating Contactor Switches, SPST-CC, Non-Directional, Overcurrent Relay. |
Westinghouse/ABB |
289B355A12 |
COM-5 Type, Single Phase, Long Time, 2-6A Time Unit, 20-80A IIT Unit, 4-8A ITH Unit, (2) 0.2/2.0A Indicating Contactor Switches, SPST-CC, Non-Directional, Overcurrent Relay. |
Westinghouse/ABB |
289B355A15 |
COM-5 Type, Single Phase, Long Time, 2-6A Time Unit, 20-80A IIT Unit, 16-32A ITH Unit, (2) 0.2/2.0A Indicating Contactor Switches, SPST-CC, Non-Directional, Overcurrent Relay. |
Westinghouse/ABB |
289B362A19 |
MG-6 Type, 6 Pole, 230V, 6 NC Contacts, 60Hz, Electric & Hand Reset, Auxiliary Relay. Ref.: 1163831. |
Westinghouse/ABB |
289B415A09 |
CP Type, Three Phase, 120VAC Nominal Range, 70-120VAC Adjustable Range, SPST-CC/CO, Undervoltage or Reverse Phase Applications, Voltage Relay |
Westinghouse/ABB |
289B415A13A |
CP Type, Reverse Phase Voltage Relay |
Westinghouse/ABB |
289B443A10 |
IRP-8 Type, 208V, 60HZ, Ground Fault Detection/ Protection, Directional Overcurrent Relay |
Westinghouse/ABB |
289B447A10 |
IRD-7 Type, Single Phase, Moderately Inverse, 0.5-2.5 Time Unit, 4-16 Instantaneous Trip, 0.2/2.0A DC Indicating Contactor Switch Unit, SPST-CC Contacts, Directional with Directional Instantaneous Trip Unit, Overcurrent Relay for Ground Fault Protection. Ref.: 184A020. |
Westinghouse/ABB |
289B473A11 |
MG-6 Type, 125VDC, 6P, 6 NC, Operating Coil Cutoff Contact, Non-Adjustable Pickup, Electric & Manual Reset, Modled Base, Glass Cover, Rear Connect, Auxiliary Relay. Ref.: 4D1076. |
Westinghouse/ABB |
289B473A21 |
MG-6 Type, 48VDC, Electric & Hand Reset with Operating Coil Cutoff Contact, Flush Case, Auxiliary Multi Contact Relay. Reference: 41-753A2 |
Westinghouse/ABB |
289B988A09 |
CW Type, Single Unit Relay, Single PHase, 120V, 20-120 Watts, SPST, 0.2/2.0A DC Indicator Contactor, Over/Reverse Power Relay |
Westinghouse/ABB |
289B988A17 |
CW Type, Three Phase, 120 V Line-Line, 20-120W, SPST-CC, Max Torque Angle is I leads V by 30 degrees. Ref.: 183A776 |
Westinghouse/ABB |
289B988A17A |
CW Type, Single Unit, Three Phase, 120V Line-Line, 20-120W, I leads V by 30deg Max Torque Angle, 0.2/2.0 Indicating Contator Switch, SPST, Over or Reverse Power Relay. Ref.: 183A776 |
Westinghouse/ABB |
290B038A09 |
CRN-1 Type, Inverse Time, 120V Line-to-Line, 0.2/2.0A Indicating Contact Switch, SPST-CC, Reverse Power, Power Directional Relay |
Westinghouse/ABB |
290B038A10 |
CRN-1 Type, Inverse Time, 120V Line-to-Line, 0.2/2.0 Indicating Contactor Switch, DPST-CC Reverse Power Relay. Ref.: 184A405. |
Westinghouse/ABB |
290B095A10 |
IRV-11 Type, Extremely Inverse, 48/125/250VDC, 0.5-2.5A Time Unit, 4-16A Instantaneous Unit, 0.2/2.0A Indicating Contactor Switch (2 Units), Phase Fault Detection, Voltage Polarized, Overcurrent/Directional/Time Relay. Ref.: 185A421. |
Westinghouse/ABB |
290B095A12D |
IRV11 Type, Directional and Time, Directional Instantaneous Trip, SPST-cc Contacts, Extremely Inverse, Phase Fault Protection, 0.2/2.0 ADC, 48/125/250 VDC, 0.5-2.5 Time Unit, 20-80 Inst. Trip |
Westinghouse/ABB |
290B114A25 |
PM-23 Type, Shortened/Open/Reversed/Remote Trip, 1.0 mA DC for NonRemote Pickup, 2.0 mA DC for Remote Pickup, 0.2/2.0 Indicating Contactor Switch, Pilot Relay. |
Westinghouse/ABB |
290B225A10 |
SA-1 Type, Solid State, Three Phase, Single Output, 0.14A Sensitivity Min Trip, 48/125VDC, Lamp Indicator, Generator Application, High Speed Differential Relay. Ref.: 629A406. |
Westinghouse/ABB |
290B225A10D |
SA-1 Type, Solid State, Three Phase, Single Output, 0.14A Sensitivity Min Trip, 48/125VDC, Lamp Indicator, Generator Application, High Speed Differential Relay. Ref.: 629A406. Complete with Reactors. |
Westinghouse/ABB |
290B346A09 |
HU Type, 60HZ, 2.9-8.7A, 0.2-2 Amps, 30% Sensitivity, SPST-CC, Transformer Differential Relay. Reference: 41-347.12C |
Westinghouse/ABB |
290B346A09A |
HU Type, 60HZ, 0.2-2 Amps, Transformer Differential Relay. Reference: 41-347.12C |
Westinghouse/ABB |
290B346A09B |
HU Type, 60HZ, 0.2-2 Amps, PU 0.3, Inst.Trip 10x Tap, Transformer Differential Relay. Reference: 41-347.1 |
Westinghouse/ABB |
290B346A10 |
HU-1 Type, Single Phase, 2.9-8.7A Rating, 30% Sensitivity, 15% Sec Harmonic Restraint, 60Hz, 0.2/2.0 Indicating Contactor Switch, SPST, High Speed Variable Percentage Differential, Transformer Differential Relay. |
Westinghouse/ABB |
290B346A21 |
HU Type, 3A Tap Pickup, Inst. Trip 10x Tap Amps, 0.2-2A Indicating Contactor Unit, Transformer Differential Relay. |
Westinghouse/ABB |
290B346A21A |
HU Type, 3A Tap Pickup, Inst. Trip 10x Tap Amps, 0.2-2A Indicating Contactor Unit, Transformer Differential Relay. |
Westinghouse/ABB |
290B346A22 |
HU-1 Type, 3A Tap Pickup, 0.2-2.0A Indicating Contactor Unit, Transformer Differential Relay. Ref.: 41-247.1. |
Westinghouse/ABB |
290B481A09 |
KLF Type, 120VAC/125VDC, 0.2/2.0A Indicator Contact Switch, FT-41 Case, Three Phase, Loss of Field, Generator Field Protection Relay. Device No.: 40. Reference: 41-702E |
Westinghouse/ABB |
290B893A09 |
CA Type, Single Phase, Inverse, .18 Minimum Trip, 10% Sensitivity, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Percentage Differential Relay for Generator Application. Ref.: 57D4553 |
Westinghouse/ABB |
291B935A09 |
CWC Type, .25-4.0 Range, 0.2/2.0 Amps Ind. Contactor, 60HZ, Single Phase, Current, FT-21 Case, Directional Ground Relay. Reference: 41-263E |
Westinghouse/ABB |
292B333A10 |
KLF-1 Type, Three Phase, 69VAC, 48VDC, 0.2/2.0A DC Indicating Contactor Switch, Loss of Field Relay. Ref.: 187A724. |
Westinghouse/ABB |
292B353A24 |
CVE-1 Type, 120V, 60Hz, Telephone Units, Synchronism Verifier Relay |
Westinghouse/ABB |
292B353A29 |
CVE-1 Type, 120V, Synchro-Verifier Relay. Ref.: 41-681.1. |
Westinghouse/ABB |
292B353A34 |
Synchro-verifier/Synch check relay, CVE-1 style, buffered cue contacts, 120V, 20-40-60 degree closing angle adjustment, .2A, SPST-CC, reference HNF-sD-LL-Es-oo4/REv |
Westinghouse/ABB |
292B353A38A |
Type CVE-1, Single Phase, 120V, 60Hz, Synchro-Verifier Relay. Ref.: 41-601.1 |
Westinghouse/ABB |
292B401A09 |
SV-1 Type, 60HZ, 70-160 Range, 8.5 V/A, Voltage Operated Mechanical Operation Indicator, 2 N.O. Contact, Overvoltage, Small Glass Projection Type, Device Number: 59, Front Connected, Instantaneous Adjustable Voltage Relay. Reference: 41-227E |
Westinghouse/ABB |
292B804A23 |
HU-4 Type,Single Phase, 2.9-8.7A, 30% Sensitivity, 15% Second Harmonic Restraint, 0.2/2.0A Indicating Contactor Switch, DPST, 4 Restraint Transformer and Bus Application, High Speed Variable Percentage Differential Relay. Ref.: 188A542. |
Westinghouse/ABB |
293B004A13 |
KC-4 Type, 2-8A AC Phase Units (2), 0.5-2.0A AC Ground Unit, 0.2/2.0 Indicating Contactor Switch, 48-125VDC, SPST, Non-Directional, Instantaneous, Overcurrent Relay. |
Westinghouse/ABB |
293B119A21 |
BL-1 Type, 1.0A Operation Indicators, 6-50A Instantaneous Trip, SPST, Frequency/Temperature/Timing Relays for AC Motors/Generators/Transformers. Ref.: 629A280. |
Westinghouse/ABB |
293B119A23 |
BL-1 Type, AC Application, Two Units Per Case, Two 6-50A Instantaneous Units, Three 0.2A Operation Indicator, SPST, Frequency/Termperature/Timing Relay. Ref.: 629A280. |
Westinghouse/ABB |
293B237A30 |
KA-4 Type, 0.5A, 125VDC, 1A Indicator Unit, Carrier Auxiliary Relay. Ref.: 41-923.4 |
Westinghouse/ABB |
293B254A20 |
SG Type, 125VDC, Non-Adjustable Pickup, DPDT, Front Connected, Self Reset, DC Voltage/Current Auxiliary Relay. Ref.: 629A337 |
Westinghouse/ABB |
293B254A20E |
SG Type, 125VDC, Non-Adjustable Pickup, DPDT, Front Connected, Self Reset, DC Voltage/Current Auxiliary Relay. Ref.: 629A337 |
Westinghouse/ABB |
293B255A18 |
SG Type, 48VDC, DPDT-2 CC, 2 CO, Front Connected, Self-Reset, Voltage Relay |
Westinghouse/ABB |
293B255A20 |
SG Type, 125VDC, Non-Adjustable Pickup, DPDT, Front Connected, Self Reset, DC Voltage/Current Auxiliary Relay. Ref.: 629A337 |
Westinghouse/ABB |
293B255A20E |
SG Type, 125VDC, Non-Adjustable Pickup, Double Pole CC/CO, Front Connected, Self Reset, DC Voltage/Current Auxiliary Relay. Reference: 41-817E |
Westinghouse/ABB |
293B285A09 |
CVE Relay, 120V, 60HZ, Syncro-verifier Relay. Reference:41-681-1 |
Westinghouse/ABB |
293B301A25B |
TD-5 Type, 48/125VDC, .02-4.0 Second, 0.2/2.0 Indicating Contactor Switch, Time Delay Relay. Ref.: 41-579.1. |
Westinghouse/ABB |
3499A08A09 |
COQ Type, Three Phase, 0.2/2.0 Indicating Contactor Switch, 3-5A Time Unit Current Range AC, SPST-CC Contacts, Overcurrent Negative Sequence Relay for Generator Protection with Self-Contained Filter. Ref.: 182A973. |
Westinghouse/ABB |
3499A08A11 |
COQ Type, Three Phase, Negative Sequence, 3-5A Time Current Range, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Generator Protection Overcurrent Relay |
Westinghouse/ABB |
410E1175 |
59G Type, Circuit Shield, Solid State, Inverse Delay, 208V, 5-120HZ, 3-18V Tap Range, 0.4-16 second Time, 48/125VDC, Frequency Compensation, Third Harmonic Rejection, Ground Overvoltage Relay. Ref.: 16D201A. |
Westinghouse/ABB |
411C4275 |
59 Type, Circuit Shield, Solid State Single Phase, Definite Time, 160V Max, 20-400Hz, 60-90V Pickup Tap Range, 1-10 second Timing Range, 48/125VDC Control Voltage, Overvoltage Relay |
Westinghouse/ABB |
411R4175 |
27D Type, Circuit Shield, Solid State, Single Phase, Definite Time, 0.1-1.0 Second Dropout, 60-110V Pickup, 70-98% Dropout of Pick Up Adjustable, 48/125VDC, 20-400Hz, 160V Max Continuous, Undervoltage Relay. |
Westinghouse/ABB |
412N4175 |
47D Type, Circuit Shield, Solid State, Three Phase, Definite Time, 1-6 Second Dropout, 90-120V Pickup, 70-98% Dropout of Pick Up Adjustable, 48/125VDC, 160V Max Continuous, Undervoltage, Phase Sequence Relay. |
Westinghouse/ABB |
412N6195 |
47D Type, Three Phase, Definite Time, 24/32VDC, 90-120V Pickup Tap Range, 70-98% of Pickup Adjustable Dropout Tap Range, 0.1-1.0 second Time Dropout, 60Hz, Undervoltage & Phase Sequence Relay. Ref.: 7417-2. |
Westinghouse/ABB |
417T2170 |
62T Type, Circuit Shield, Solid State, 48/125VDC, 2 Form C Output Contacts, 0.01 - 0.99 second Timing Range, Time Delay Relay. Ref.: 16D417G. |
Westinghouse/ABB |
419B0042 |
87B Type, Circuit Shield, 125VDC, 60Hz, High Impedance Differential Relay. Reference: 41-357S |
Westinghouse/ABB |
419T2441 |
Type 87T, Circuit Shield, Solid State, Voltage Regulator, Single Phase with Harmonic Restraint, 125VDC, 15-40% Differential, 1.0-2.6 Minimum Restraint, Manual Reset, 2 Winding Transformer Differential Relay. Ref.: 16D419B. |
Westinghouse/ABB |
419T2441 |
Type 87T, CIrcuit Shield, Voltage Regulator, 125VDC, 15-40% Differential, 1.0-2.6 Minimum Restraint, Manual Reset |
Westinghouse/ABB |
422C1276 |
81 Type, Circuit Shield, Solid State, Definite Timing, 140V Max, 1 Step, 63-54Hz, 48/125 VDC, 1-99 Cycles, Frequency Relay. Ref.: 16D422A. |
Westinghouse/ABB |
422C1296 |
81 Type, Solid State, Circuit Shield, Two Step, Definite Curve, 24/32VDC, 63-54Hz, 140V Max Rating, Frequency Relay. Ref.: 16D422B. |
Westinghouse/ABB |
423S2190 |
51Y Type, Circuit Shield, Single Phase, Very Inverse, 0.5-2A Time Unit Pickup Range, 2-20A Instantaneous Attachment, 32VDC, Thyristor Output, Time Overcurrent Relay |
Westinghouse/ABB |
423S3240 |
51E Type, Circuit Shield, Solid State, Single Phase, Extremely Inverse Time, 1.5-6A Time Unit, 125VDC,Time-Overcurrent Relay. |
Westinghouse/ABB |
423S4490 |
51S Type, Circuit Shield, Solid State, Single Phase, Short Time, 0.1-0.5A Time Unit, Contact Output, 32VDC, Time-Overcurrent Relay. |
Westinghouse/ABB |
423T1241 |
51I Type, Circuit Shield, Solid State, Three Phase, Inverse Time, 1.5-6A Time Unit, 2-20A Instantaneous Unit, 125VDC, Time-Overcurrent Relay. |
Westinghouse/ABB |
426E1170 |
40 Type, Circuit Shield, Solid State, Definite Time, 208 VAC, 10A, 48/125VDC, MHO Circle Characteristic, Loss of Excitation Relay. Ref.: 16D426A. |
Westinghouse/ABB |
427F1571 |
46Q Type, Solid State, Circuit Shield, Three Phase, Inverse Time with Thermal Memory, 48/125VDC, 8A, 10-40s, Negative Sequence Time-OVercurrent Relay. Ref.: 16D427B. |
Westinghouse/ABB |
427Q4471 |
46D Type, Circuit Shield, Solid State, Three Phase, Definite Time, 8A Continuous Rating, 0.3-1.2A Pickup, 0.5-4 Second Operating, 48/125VDC, Current Balance, Negative Sequence Relay. |
Westinghouse/ABB |
430F0261 |
64F Type, Circuit Shield, Solid State, 5000 Ohms ground on negative lead Minimum Sensitivity, 600VDC or less Nominal, 750VDC Ceiling, 1200VDC Max Machine Field Voltage, Machine Field Ground Detector Relay. Ref.: 16D430FG. |
Westinghouse/ABB |
443P3341 |
51E Type, Circuit Shield, Solid State, Extremely Inverse, 125VDC, 5 Targets, 4-12A Time Unit, 2-20A Instantaneous Attachment in Multiples of Tap Setting, Standard, Time Overcurrent Relay |
Westinghouse/ABB |
443S1241 |
51I Type, Solid State, Circuit Shield, Single Phase, 125VDC, 1.5-6A Time Unit Pickup Range, 2-20A Instantaneous Unit Range, Time Overcurrent Relay. |
Westinghouse/ABB |
443S2230 |
51Y Type, Solid State, Circuit Shield, Single Phase, Very Inverse, 48VDC, 1.5-6A Time Unit Pick Up Range, Contact Output, Time Overcurrent Relay. |
Westinghouse/ABB |
443S3240 |
Type 51E, Circuit Shield, Solid State, Single Phase, Extremely Inverse, 1.5-6A Time Unit Pickup Range, 125VDC, No Instanteous, Thyristor Output, 50/60Hz, Time Overcurrent Relay. |
Westinghouse/ABB |
443T2341 |
51Y Type, Solid State, Circuit Shield, Very Inverse, Three Phase, 4-12A Time Unit, 2-20A Instantaneous, 125VDC, Contact Output, Time Overcurrent Relay |
Westinghouse/ABB |
443T3361 |
51E Type, Circuit Shield, Solid State, Extremely Inverse, Three Phase, 4-12A Time Unit, 2-20A Instantaneous Unit in Multiples of Tap Setting, 120VAC, 50/60Hz, Time Overcurrent Relay. |
Westinghouse/ABB |
446S1201 |
Micro-51 Type, Solid State, Single Phase, Inverse to LT Extremely Inverse, 20A Continuous Rating,1.5-12A Time-Pickup Range, 1-20A Instantaneous Range as Multiples of Pickup Setting, No Torque Control, Contact Output, Self-Powered, Time Overcurrent Relay. |
Westinghouse/ABB |
474M14116000 |
Circuit Shield, Solid State, 1.5-12A Phase Range, 1.5-12A Ground Range, 60-150VDC, (1) one Trip, (4) four Programmable Output Contacts, (0) zero Voltage Inputs, Front RS232/Rear RS485 ports, 60Hz, No Recloser, ASCII & Modbus Protocol, Microshield Relay. |
Westinghouse/ABB |
505A650G02 |
W2 Type, 12 Contacts, Stop Pin at 2 and 12, Fixed Handle, 1 1/2" Panel Switch. |
Westinghouse/ABB |
606B029A09 |
AR Type, 2 Millisecond Operating Time, Non-Adjustable Pick up, Single Unit, 4 make Contacts, 125VDC, Front Connected, Glass Window Cover, Auxiliary Tripping, Annunciator Relay. Ref.: 629A899. |
Westinghouse/ABB |
606B029A13 |
AR Type, Single Unit, 125V, 2 Make/2 Break Contacts, Front Connected, Glass Window Cover, Auxiliary, Non-Adjustable Pickup, 2 Millisecond Operating Time, Molded Base Type, Auxiliary Relay. Ref.: 837A112. |
Westinghouse/ABB |
6668D37A22A |
Instantaneous, High Impedance, Bus Differential, 75-200VAC, 3-48A, 0.2/2.0 ICS |
Westinghouse/ABB |
670B326A09A |
KC-2 Type, Instantaneous, 2-8A, 0.2/2.0 Indicating Contactor Switch, SPST-CC, Overcurrent, Non-Directional Relay. Ref.: 837A454. |
Westinghouse/ABB |
671B157A20 |
CA-16 Type, Single Phase, Inverse Time, 0.15A Minimum Trip, 0.15A Fault Detector, 0.2/2.0A Indicating Contactor Switch, SPST, Variable Sensitivity, Bus Application, Percentage Differential Relay. |
Westinghouse/ABB |
671B287A09 |
KF Type, 55.0-59.5 Adjustable Hz, 6-30 Cycle Time Delay, 120V, 48/125V TIming Circuit Voltage Rating, 0.2/2.0 Indicating Contactor Switch, SPST, Instantaneous, Underfrequency Relay. Ref.: 849A318. |
Westinghouse/ABB |
671B287A15 |
KF Type, Instantaneous, 120V, 120VAC (adj.) Timing Circuit Voltage Rating, 55.0-59.5Hz Adjustable Range, 6-30Hz (adj.) Time Delay, 0.2/2.0a Indicating Contactor Switch, SPDT-CC & CO, Underfrequency Relay. Ref.: 862A525. |
Westinghouse/ABB |
671B636A09 |
JM Type, Single Unit, 120VAC, 60Hz, Rear Connected, Semi Flush, Glass Window Cover, Annunciator Relay. Ref.: IL41-741 |
Westinghouse/ABB |
717B920A10 |
SDF-1 Type, 120V, 54-60Hz, 48/175VDC, Digital Underfrequency Relay. Ref.: 41-504.1. |
Westinghouse/ABB |
719B195A10 |
KD-10 Type, 3 Phase, 1, 2, 3, or 4 Zone, 5A, 0.2-4.5 Secondary Ohms-Line-To-Neutral, 75 degrees max, 60 degrees torque angle setting, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Distance Relay. Ref.: 3490A81. |
Westinghouse/ABB |
719B195A11 |
KD-10 Type, Three Phase, 75deg, 0.75-21 Secondary Ohms to Line Neutral, 0.2/2.0 Indicating Contactor Unit, 5A, SPST, Phase Protection, Distance Relay. Ref.: 3507A70. |
Westinghouse/ABB |
719B195A22 |
KD-10 Type, 3 Phase, 1, 2, 3, or 4 Zone, 5A, 0.2-4.5 Secondary Ohms-Line-To-Neutral, 75 degrees max, 75 degrees torque angle setting, 0.2/2.0A Indicating Contactor Switch, SPST-CC, Distance Relay. Ref.: 3507A64. |
Westinghouse/ABB |
719B195A26 |
KD-10 Type, Phase Protection, Three Phase, 0.66-19 Secondary Ohms-Line-to-Neutral Range, 75 Degree Max Torque Angle Setting, 1.0 Indicating Contactor Switch, SPST-CC, Distance Relay. Ref.: 3514A66. |
Westinghouse/ABB |
719B196A11 |
KD-11 Type, Three Phase, 1 - 4 Zone Protection, 5A, 120VAC, 0.75-21 Secondary Ohms-Line-To-Neutral Range, 75 Degree Max Torque Angle Phi-Phi Unit, 75 Degree Max Torque Angle 3Phi Unit, 0.2/2.0 Indicating Contactor Switch, SPST, Distance Relay. Ref.: 3490A82. |
Westinghouse/ABB |
A2F1M2C0PA |
E1B-2E Type, Solid State, 2 Element Meter |
Westinghouse/ABB |
CO11H1101N |
CO-11 Type, Single Phase, 1-12A Overcurrent Unit, 0.2/2.0A Indicating Contactor Unit, Overcurrent Relay. Ref.: 57D4523. |
Westinghouse/ABB |
MGF70N70MMMMMM |
MG-6 Type, 48VDC, No Coil Interrupting Contact, 48VDC Reset Coil, Standard Make, Front Connected, Projection Mounted, Window Cover, Auxiliary Relay |
Westinghouse/ABB |
MMZT573GC1 |
MMCO Type, 48/125VDC, 50/60Hz, 5A, Multiphase Overcurrent Relay. |
Westinghouse/ABB |
MMZT5Z3ZG1 |
MMCO Type, 48/125VDC, 50/60Hz, 5A, Multiphase Overcurrent Relay. |
Westinghouse/ABB |
MMZZ5Z3ZG1 |
MMCO Type, 48/125VDC, 50/60Hz, 5A, Multiphase Overcurrent Relay. |
Westinghouse/ABB |
Replacement ICS Coil | |
|
|