Software 2 |
|
Code |
Software options 2 for Model 2500 |
Z |
No software options 2 |
C |
Smart Meter Verification |
|
Not available with Mounting Option B; Smart Meter Verification is not available with all sensors. |
W |
Weights and measures custody transfer (requires user-provided external sealing for approval) |
D |
Weights and measures custody transfer & Smart Meter Verification (requires user-provided external sealing) |
|
Not available with Mounting Option B; Smart Meter Verification is not available with all sensors. |
X |
ETO software option 2 |
|
Requires factory code X |
Factory |
|
Code |
Factory options for Model 2500 |
Z |
Standard product |
X |
ETO product |
Add on Options |
|
Code |
Add on options for Model 2500 |
|
Country specific approval (select one from the following if approval code G is selected): |
R4 |
EAC Safe Area Only with IS Sensor Outputs - Hazardous Area Approval |
B4 |
INMETRO Safe Area Only with IS Sensor Outputs - Hazardous Area Approval |
Model 2700 |
|
Base model |
|
Model |
Product description |
2700 |
Micro Motion Coriolis MVD Model 2700 multivariable flow and density transmitter |
Series 1000 and 2000 Transmitters |
Mounting |
|
Code |
Mounting options for Model 2700 |
R |
4-wire remote mount transmitter (polyurethane-painted aluminum housing) includes 10 ft. [3m] 4 wire shielded PVC cable |
I |
Integral mount transmitter (polyurethane-painted aluminum housing) |
E |
4-wire remote mount transmitter with 9-wire remote enhanced core processor; includes 10 ft. (3 m) each of 4-wire shielded PVC cable and 9-wire shielded FEP cable; |
|
Mounting code B, E not available with conduit connection code C or D; Available with approval options M, C, A, F, Z, P or I only; Not available with approval option codes S or T or with Conduit Connections L or M. |
B |
4-wire remote mount transmitter with 9-wire remote core processor (polyurethane-painted aluminum housing) includes 10 ft. [3m] each 9 wire shielded FEP and 4 wire shielded PVC cable |
|
Mounting code B, E not available with conduit connection code C or D |
C |
9-wire remote transmitter with integral core processor (polyurethane-painted aluminum housing) includes 10 ft. [3m] CFEPS cable |
|
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G with country-specific appro-val codes R1 and B1; |
M |
4-wire remote mount transmitter with stainless steel housing; includes 10 ft. (3 m) 4-wire shielded PVC cable; |
|
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not Zone 1 increased safety (Ex e) approved. |
P |
9-wire remote mount transmitter with stainless steel housing and integral core processor; includes 10 ft. (3m) CFEPS cable |
|
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not Zone 1 increased safety (Ex e) approved. |
H |
4-wire remote mount transmitter (polyurethane-painted aluminum housing) for connecting to CDM/FDM/FVM meters [power and communications] includes 10ft (3m) 4 wire shielded PVC cable |
|
Not available with approval codes J, T or S |
Power |
|
Code |
Power options for Model 2700 |
1 |
18 to 100 VDC or 85 to 265 VAC; self switching |
Display |
|
Code |
Display options for Model 2700 |
1 |
Dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings; |
|
Not available with mounting codes M, P; or H |
2 |
Backlit dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings |
3 |
No display |
|
Not available with approval codes J, T, or S |
5 |
Backlit dual line display for IIC ATEX, IECEx, and NEPSI rating |
|
Only available with approval codes Z, F, P, K, I, E, L, or 3 |
Code |
Display options for Model 2700 |
7 |
Backlit dual line display for process variables and totalizer reset, non-glass lens |
|
Only available with approval code M; not available with mounting codes M, H, or P |
8 |
Display optimized for Chinese-language support; China only |
|
Only available with mounting code R, I, C, or B, output code A, conduit connection code B, C, D, E, F or G, and approval code M, Z, F, P, K, I, or G code with country specific approval R1, R2, B1, B2 |
Output |
|
Code |
Output options for Model 2700 |
A |
Analog outputs: one mA; one frequency; RS-485 |
|
Not available with mounting code H |
B |
One mA; two configurable IO channels - default configuration of 2 mA, 1 FO |
|
Not available with mounting code H |
C |
One mA; two configurable IO channels - custom configuration |
|
Not available with mounting code H |
D |
Intrinsically safe analog outputs: two mA, one frequency; |
|
Not available with mounting code H; Output code D and E are not available with approval codes T, S, and J. |
E |
Foundation fieldbus intrinsically safe H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO) |
|
Output code D and E are not available with approval codes T, S, and J; Output code E is not available with approval code U, 2, L, 3 or G with country specific approval codes R3 or B3 |
G |
PROFIBUS-PA; not available with approval codes U, 2, L and 3 |
|
Output code G not available with approval codes U, 2, L , 3 or G with country-specific approval option R3, B3; not available with mounting code H: |
N |
Foundation Fieldbus H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO); |
|
Output code N is not available with approval codes U, C, A, E, 2, L, 3 or G with country-specific approval R3, B3 |
2 |
One mA; one frequency; RS485; Wireless HART ready; order 775 with 1/2�?NPT mounting option |
|
Not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with country-specific approval R3, B3. |
3 |
One mA; two configurable IO channels - custom configuration; Wireless HART ready; order 775 with 1/2�?NPT mounting option |
|
Not available with approvals J, T or S; not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with country-specific approval R3, B3. |
4 |
Intrinsically safe outputs; two mA; one frequency; Wireless HART ready; order 775 with 1/2�?NPT mounting option |
|
Not available with mounting code H; output code 4 is only available with approval codes E, Z, A, or G with country-specific approval R1, B1 when using stopping box |
Conduit connection |
|
Code |
Conduit connection options for Model 2700 |
|
Available with mounting codes: |
B |
1/2-inch NPT - no gland; Not available with approval code T, S, or J |
|
Only available with mounting code R, I, B, E, C, M, or P: |
C |
1/2-inch NPT with brass nickel cable gland (not approved in Class 1 Division 1 installations) Not available with approval code T, S, or J; mounting code B, E not available with Conduit Connection C or D; not available with mounting code M, or P |
D |
1/2-inch NPT with stainless steel cable gland (not approved in Class 1 Division 1 installations) Not available with approval codes J, T, or S; mounting codes B or E not available with Conduit Connection codes C or D |
E |
M20 - no gland Not available with approvals T or S |
F |
M20 with brass nickel cable gland (not approved in Class 1 Division 1 installations) Not available with mounting code M or P |
G |
M20 with stainless steel cable gland (not approved in Class 1 Division 1 installations) |
K |
JIS B0202 1/2G - no gland Only available with approval code M; not available with mounting code M or P |
L |
Japan - brass nickel cable gland Only available with approval codes M, T, or S; not available with mounting code M or P |
M |
Japan - stainless cable gland Only available with approval codes M, T, or S; not available with mounting code M or P |
Approval |
|
Code |
Approval options for Model 2700 |
M |
Micro Motion Standard (no approval, with CE/EAC mark) |
U |
UL |
|
Approval code U is available with conduit codes B or E only. |
C |
CSA (Canada only) |
A |
CSA C-US (US and Canada) |
Z |
ATEX - Equipment Category 2 (Zone 1 - Increased safety terminal compartment) |
F |
ATEX - Equipment Category 2 (Zone 1 - Flameproof terminal compartment) |
Code |
Approval options for Model 2700 |
P |
NEPSI �?Equipment Category 2 (Zone 1�?Flameproof terminal compartment); |
|
Available with Chinese (M) language option only |
K |
NEPSI �?Equipment Category 2 (Zone 1 �?Increased safety terminal compartment) |
|
Available with Chinese (M) language option only |
I |
IECEx Equipment Category 2 (Zone 1 �?Flameproof terminal compartment) |
T |
TIIS - IIC sensor (not available for quotes outside of Japan) |
|
Available for quote only |
S |
TIIS - IIB sensor (not available for quotes outside of Japan) |
|
Available for quote only |
J |
Hardware ready for TIIS approval (EPM Japan only) |
|
Approval code J is only available with Conduit Connections Option E; Available for order only |
E |
IECEx (Zone 1 - Increased safety terminal compartment) |
|
Only available with output code 4 |
2 &nb, sp; |
CSA Class 1 Div. 2 (US and Canada) |
|
Sensor connections will be intrinsically Safe without additional barrier |
L |
ATEX - Equipment Category 3 (Zone 2) |
|
Sensor connections will be intrinsically Safe without additional barrier; Approval code L is only available with output options 2 and 3. |
3 |
IECEx (Zone 2) |
|
Sensor connections will be intrinsically Safe without additional barrier |
G |
Country Specific Approval - Requires a selection from the Approvals section of the Add on Options |
Language |
|
Code |
Language options for Model 2700 |
A |
Danish CE requirements document; English installation and configuration manuals |
D |
Dutch CE requirements document; English installation and configuration manuals |
E |
English installation manual; English configuration manual |
F |
French installation manual; French configuration manual |
G |
German installation manual; German configuration manual |
H |
Finnish CE requirements document; English installation and configuration manuals |
I |
Italian installation manual; English configuration manual |
J |
Japanese installation manual; Japanese configuration manual |
M |
Chinese installation manual; Chinese configuration manual |
N |
Norwegian CE requirements document; English installation and configuration manuals |
O |
Polish installation manual; English configuration manual |
P |
Portuguese installation manual; English configuration manual |
S |
Spanish installation manual; Spanish configuration manual |
W |
Swedish CE requirements document; English installation and configuration manuals |
Code |
Language options for Model 2700 |
C |
Czech CE requirements document; English installation and configuration manuals |
B |
Hungarian CE requirements document; English installation and configuration manuals |
K |
Slovak CE requirements document; English installation and configuration manuals |
T |
Estonian CE requirements document; English installation and configuration manuals |
U |
Greek CE requirements document; English installation and configuration manuals |
L |
Latvian CE requirements document; English installation and configuration manuals |
V |
Lithuanian CE requirements document; English installation and configuration manuals |
Y |
Slovenian CE requirements document; English installation and configuration manuals |
Software 1 |
|
Code |
Software options 1 �?only available with mounting codes R, I, B, E, C, M, and P |
Z |
Flow and density variables (standard) |
G |
Concentration measurement |
A |
Petroleum measurement |
J |
Production Volume Reconciliation |
|
Approval code J is only available with conduit connections option E. |
K |
Transient Mist Remediation |
|
Approval code J is only available with conduit connections option E. |
L |
Transient Bubble Remediation |
|
Approval code J is only available with conduit connections option E. |
M |
Fuel consumption |
|
Approval code J is only available with conduit connections option E. |
Q |
Transient Bubble Remediation and petroleum measurement |
|
Approval code J is only available with conduit connections option E. |
R |
Piece-wise linearization for gas |
|
Approval code J is only available with conduit connections option E. |
X |
ETO software option 1 |
|
Requires factory code X |
|
|
Code |
Software options 1 �?only available with mounting code H (1) All concentration measurement or petroleum measurement options are automatically programmed by the CDM / FDM. |
B |
CDM density meter connection - IIC ATEX & IECEx rating |
|
Not available with display code 2 |
C |
FDM density meter connection - IIC ATEX & IECEx rating |
|
Not available with display code 2 |
D |
FVM viscosity meter connection - IIC ATEX & IECEx rating |
|
Not available with display code 2 |
E |
CDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings |
|
Not available with display code 5 |
F |
FDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings |
|
Not available with display code 5 |
H |
FVM viscosity meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings |
|
Not available with display code 5 |
Software 2 |
|
Code |
Software options 2 for Model 2700 �?available with all mounting codes |
Z |
No software options 2 |
W |
Weights & measures custody transfer |
|
Only available with output codes A, B, C, 2 or 3; Not available with Software Options 1 codes C or D |
X |
ETO software option 2; requires factory code X |
Code |
Software options 2 for Model 2700 �?available only with mounting codes R, I, B, E, C, or M and P |
C |
Smart Meter Verification |
|
Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors. |
D |
Weights & measures custody transfer and Smart Meter Verification |
|
Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors. |
A |
Regulatory Control Suite: Standard function blocks plus 1 PID block |
|
Available with output codes E and N only |
F |
Regulatory Control Suite: Standard function blocks plus 1 PID block & Smart Meter Verification |
|
Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not available with mounting option I, B, E, C, or P |
S |
Safety Certification of 4-20 mA output per IEC 61508 |
|
Available with Output codes A, B, C, and D only |
Code |
Software options 2 for Model 2700 �?available only with mounting codes R, I, B, E, C, or M and P |
V |
Safety Certification per IEC 61508 with Smart Meter Verification |
|
Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not available with mounting option I, B, E, C, or P; Not available with approval options S or T with conduit connections L or M |
Factory |
|
Code |
Factory options for Model 2700 |
Z |
Standard product |
X |
ETO product |
Add on Options |
|
Code |
Add on options for Model 2700 �?Available only for output code 2, 3, or 4 |
PI |
Model 775 integrally mounted at the factory, wiring completed in the field |
|
Not available with approvals J, T, or S; Add on option PI is not available with Output code 4 and approval code A. CSA requires installation with a poured conduit seal or stopping box between the transmitter and the 775 Thum. |
NI |
Model 775 not installed, installation and wiring completed in the field |
|
Not available with approvals J, T, or S |
Code |
Add on options for Model 2700 �?for mounting code R, B, E, H, M, P, or C |
PK |
2-inch pipe mount U-bolt kit for electronics |
Code |
Add on options for Model 2700 �?Country‐specific approval (select one from the following if approval code G is selected) |
R1 |
EAC Zone 2 - Hazardous Area Approval - Increased safety terminal compartment (Exe) |
R2 |
EAC Zone 1 - Hazardous Area Approval - Flameproof terminal compartment |
R3 |
EAC Zone 2 - Hazardous Area Approval - Energy limited device (ExnA ) |
|
Sensor connections will be intrinsically safe without additional barrier |
B1 |
INMETRO Zone 1 - Hazardous Area Approval - Increased safety terminal compartment N/C |
B2 |
INMETRO Zone 1 - Hazardous Area Approval - Flameproof terminal compartment |
B3 |
INMETRO Zone 2 - Hazardous Area Approval |
|
Sensor connections will be intrinsically safe without additional barrier |