BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  

Mail List

E-mail:

spare parts
     Bently Nevada  
     Speedtronic  
     GE-Fanuc  
     GE Druck  
     GE-Multilin  
     GE Panametrics  
     GE Energy  
     FLENDER & Flender Graffenstaden  
     QUALITROL  
     KANEKO  
     Schneider Electric  
       Telemecanique  
       Gutor Electronic  
       Invensys Foxboro  
       Square D  
       Merlin Gerin  
       APC  
     Auma  
     Siemens  
     Woodward  
     ATLAS COPCO  
     NUOVO PIGNONE  
     ABB  
       BALDOR  
     Michell Instruments  
     Foxboro  
     Vickers  
     ITT Goulds Pumps  
     Metso  
       Neles  
       Jamesbury  
       Mapag  
       Stonel  
     Dwyer  
     Blade, Vane for NP, PGT-10, Frame 3, Frame 5  
     Emerson  
       Appleton  
       Control Techniques  
       Rosemount  
       TOPWORX   
       Go Switch  
     Honeywell  
       FEMA  
       MAXON  
       RMG  
     metrix vibration  
     Allen-Bradley  
     Yokogawa  
     ALLWEILER  
     CCS  
     Deutz-MWM  
     Caterpillar  
     Esco Couplings  
     NORGREN  
     Parker  
     Invensys  
     Asco  
     Swagelok  
     AMERICAN-AIR-FILTER(AAF)  
     HERION  
     Dynisco  
     Pepperl+Fuchs(P+F)  
     Fisher  
     Timken  
     Philadelphia Gear(Western Gear, WesTech)  
     Coaxial Valves  
     DENARDO WIRE & CABLE  
     leslie Laurence Valve  
     Altra motion  
     Colfax Corporation  
       Allweiler  
       Houttuin  
       IMO  
       Tushaco  
       Warren Pumps  
       Zenith  
     ROTORK  
     MOOG  
     DOLLINGER CORPORATION  
     Viking-Pump  
     Samson  
     KRAISSL  
     KRACHT  
     ECO Gearchem  
     Pratt & Whitney  
     OVAL  
     Roper Pump  
     Rechner Sensors  
     Westinghouse  
     Rockwell  
     ENDRESS+HAUSER(E+H)  
     Cummins  
     DET-TRONICS  
     GE-Breaker  
     Masoneilan  
     MTU  
     Omron  
     CHINT  
     China OEM Equipment and Spare Parts  
       Boiler-spare-parts  
       Chemical-Equipment-spare-parts  
       Thermal-control-equipment-spare-parts  
       Environmental-protection-equipment-spare-parts  
       Electrical-equipment-spare-parts  
       Transfer-equipment-spare-parts  
       Gas-turbine-equipment-spare-parts  
     TB WOODS  
     Bruel & Kjaer Vibro  
     Perkins  
     Flowserve   
     IMO  
     SCHUNK  
     KAVLICO  
     GORTER  
     GEORG FISCHER  
     WILDEN  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > spare parts > Emerson > Rosemount - Rosemount 2700-R.1.1.E.F.F.E.Z.A.Z Mass Flow & Density Transmitter


Google

Rosemount 2700-R.1.1.E.F.F.E.Z.A.Z Mass Flow & Density Transmitter

 Software 2  
 Code    Software options 2 for Model 2500  
 Z    No software options 2  
 C    Smart Meter Verification  
   Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.  
 W    Weights and measures custody transfer (requires user-provided external sealing for approval)  
 D    Weights and measures custody transfer & Smart Meter Verification (requires user-provided external sealing)  
   Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.  
 X    ETO software option 2  
   Requires factory code X  
 Factory  
 Code    Factory options for Model 2500  
 Z    Standard product  
 X    ETO product  
 Add on Options  
 Code    Add on options for Model 2500  
   Country specific approval (select one from the following if approval code G is selected):  
 R4    EAC Safe Area Only with IS Sensor Outputs - Hazardous Area Approval  
 B4    INMETRO Safe Area Only with IS Sensor Outputs - Hazardous Area Approval  
 Model 2700  
 Base model  
 Model    Product description  
 2700    Micro Motion Coriolis MVD Model 2700 multivariable flow and density transmitter  
Series 1000 and 2000 Transmitters
 Mounting    
 Code    Mounting options for Model 2700  
 R    4-wire remote mount transmitter (polyurethane-painted aluminum housing) includes 10 ft. [3m] 4 wire shielded PVC cable  
 I    Integral mount transmitter (polyurethane-painted aluminum housing)  
 E    4-wire remote mount transmitter with 9-wire remote enhanced core processor; includes 10 ft. (3 m) each of 4-wire shielded PVC cable and 9-wire shielded FEP cable;  
   Mounting code B, E not available with conduit connection code C or D; Available with approval options M, C, A, F, Z, P or I only; Not available with approval option codes S or T or with Conduit Connections L or M.  
 B    4-wire remote mount transmitter with 9-wire remote core processor (polyurethane-painted aluminum housing) includes 10 ft. [3m] each 9 wire shielded FEP and 4 wire shielded PVC cable  
   Mounting code B, E not available with conduit connection code C or D  
 C    9-wire remote transmitter with integral core processor (polyurethane-painted aluminum housing) includes 10 ft. [3m] CFEPS cable  
   Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G with country-specific appro-val codes R1 and B1;  
 M    4-wire remote mount transmitter with stainless steel housing; includes 10 ft. (3 m) 4-wire shielded PVC cable;  
   Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not Zone 1 increased safety (Ex e) approved.  
 P    9-wire remote mount transmitter with stainless steel housing and integral core processor; includes 10 ft. (3m) CFEPS cable  
   Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not Zone 1 increased safety (Ex e) approved.  
 H    4-wire remote mount transmitter (polyurethane-painted aluminum housing) for connecting to CDM/FDM/FVM meters [power and communications] includes 10ft (3m) 4 wire shielded PVC cable  
   Not available with approval codes J, T or S  
 Power  
 Code    Power options for Model 2700  
 1    18 to 100 VDC or 85 to 265 VAC; self switching  
 Display  
 Code    Display options for Model 2700  
 1    Dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings;  
   Not available with mounting codes M, P; or H  
 2    Backlit dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings  
 3    No display  
   Not available with approval codes J, T, or S  
 5    Backlit dual line display for IIC ATEX, IECEx, and NEPSI rating  
   Only available with approval codes Z, F, P, K, I, E, L, or 3  
 Code    Display options for Model 2700  
 7    Backlit dual line display for process variables and totalizer reset, non-glass lens  
   Only available with approval code M; not available with mounting codes M, H, or P  
 8    Display optimized for Chinese-language support; China only  
   Only available with mounting code R, I, C, or B, output code A, conduit connection code B, C, D, E, F or G, and approval code M, Z, F, P, K, I, or G code with country specific approval R1, R2, B1, B2  
 Output  
 Code    Output options for Model 2700  
 A    Analog outputs: one mA; one frequency; RS-485  
   Not available with mounting code H  
 B    One mA; two configurable IO channels - default configuration of 2 mA, 1 FO  
   Not available with mounting code H  
 C    One mA; two configurable IO channels - custom configuration  
   Not available with mounting code H  
 D    Intrinsically safe analog outputs: two mA, one frequency;  
   Not available with mounting code H; Output code D and E are not available with approval codes T, S, and J.  
 E    Foundation fieldbus intrinsically safe H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO)  
   Output code D and E are not available with approval codes T, S, and J; Output code E is not available with approval code U, 2, L, 3 or G with country specific approval codes R3 or B3  
 G    PROFIBUS-PA; not available with approval codes U, 2, L and 3  
   Output code G not available with approval codes U, 2, L , 3 or G with country-specific approval option R3, B3; not available with mounting code H:  
 N    Foundation Fieldbus H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO);  
   Output code N is not available with approval codes U, C, A, E, 2, L, 3 or G with country-specific approval R3, B3  
 2    One mA; one frequency; RS485; Wireless HART ready; order 775 with 1/2�?NPT mounting option  
   Not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with country-specific approval R3, B3.  
 3    One mA; two configurable IO channels - custom configuration; Wireless HART ready; order 775 with 1/2�?NPT mounting option  
   Not available with approvals J, T or S; not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with country-specific approval R3, B3.  
 4    Intrinsically safe outputs; two mA; one frequency; Wireless HART ready; order 775 with 1/2�?NPT mounting option  
   Not available with mounting code H; output code 4 is only available with approval codes E, Z, A, or G with country-specific approval R1, B1 when using stopping box  
 Conduit connection  
 Code    Conduit connection options for Model 2700  
Available with mounting codes:
B 1/2-inch NPT - no gland;  Not available with approval code T, S, or J
Only available with mounting code R, I, B, E, C, M, or P:
C 1/2-inch NPT with brass nickel cable gland (not approved in Class 1 Division 1 installations)  Not available with approval code T, S, or J; mounting code B, E not available with Conduit Connection C or D; not available with mounting code M, or P
D 1/2-inch NPT with stainless steel cable gland (not approved in Class 1 Division 1 installations)  Not available with approval codes J, T, or S; mounting codes B or E not available with Conduit Connection codes C or D
E M20 - no gland  Not available with approvals T or S
F M20 with brass nickel cable gland (not approved in Class 1 Division 1 installations)  Not available with mounting code M or P
G M20 with stainless steel cable gland (not approved in Class 1 Division 1 installations)
K JIS B0202 1/2G - no gland  Only available with approval code M; not available with mounting code M or P
L Japan - brass nickel cable gland  Only available with approval codes M, T, or S; not available with mounting code M or P
M Japan - stainless cable gland  Only available with approval codes M, T, or S; not available with mounting code M or P
 Approval    
 Code    Approval options for Model 2700  
 M    Micro Motion Standard (no approval, with CE/EAC mark)  
 U    UL  
   Approval code U is available with conduit codes B or E only.  
 C    CSA (Canada only)  
 A    CSA C-US (US and Canada)  
 Z    ATEX - Equipment Category 2 (Zone 1 - Increased safety terminal compartment)  
 F    ATEX - Equipment Category 2 (Zone 1 - Flameproof terminal compartment)  
 Code    Approval options for Model 2700  
 P    NEPSI �?Equipment Category 2 (Zone 1�?Flameproof terminal compartment);  
   Available with Chinese (M) language option only  
 K    NEPSI �?Equipment Category 2 (Zone 1 �?Increased safety terminal compartment)  
   Available with Chinese (M) language option only  
 I    IECEx Equipment Category 2 (Zone 1 �?Flameproof terminal compartment)  
 T    TIIS - IIC sensor (not available for quotes outside of Japan)  
   Available for quote only  
 S    TIIS - IIB sensor (not available for quotes outside of Japan)  
   Available for quote only  
 J    Hardware ready for TIIS approval (EPM Japan only)  
   Approval code J is only available with Conduit Connections Option E; Available for order only  
 E    IECEx (Zone 1 - Increased safety terminal compartment)  
   Only available with output code 4  
 2 &nb, sp;  CSA Class 1 Div. 2 (US and Canada)  
   Sensor connections will be intrinsically Safe without additional barrier  
 L    ATEX - Equipment Category 3 (Zone 2)  
   Sensor connections will be intrinsically Safe without additional barrier; Approval code L is only available with output options 2 and 3.  
 3    IECEx (Zone 2)  
   Sensor connections will be intrinsically Safe without additional barrier  
 G    Country Specific Approval - Requires a selection from the Approvals section of the Add on Options  
 Language  
 Code    Language options for Model 2700  
 A    Danish CE requirements document; English installation and configuration manuals  
 D    Dutch CE requirements document; English installation and configuration manuals  
 E    English installation manual; English configuration manual  
 F    French installation manual; French configuration manual  
 G    German installation manual; German configuration manual  
 H    Finnish CE requirements document; English installation and configuration manuals  
 I    Italian installation manual; English configuration manual  
 J    Japanese installation manual; Japanese configuration manual  
 M    Chinese installation manual; Chinese configuration manual  
 N    Norwegian CE requirements document; English installation and configuration manuals  
 O    Polish installation manual; English configuration manual  
 P    Portuguese installation manual; English configuration manual  
 S    Spanish installation manual; Spanish configuration manual  
 W    Swedish CE requirements document; English installation and configuration manuals  
 Code    Language options for Model 2700  
 C    Czech CE requirements document; English installation and configuration manuals  
 B    Hungarian CE requirements document; English installation and configuration manuals  
 K    Slovak CE requirements document; English installation and configuration manuals  
 T    Estonian CE requirements document; English installation and configuration manuals  
 U    Greek CE requirements document; English installation and configuration manuals  
 L    Latvian CE requirements document; English installation and configuration manuals  
 V    Lithuanian CE requirements document; English installation and configuration manuals  
 Y    Slovenian CE requirements document; English installation and configuration manuals  
 Software 1  
 Code    Software options 1 �?only available with mounting codes R, I, B, E, C, M, and P  
 Z    Flow and density variables (standard)  
 G    Concentration measurement  
 A    Petroleum measurement  
 J    Production Volume Reconciliation  
   Approval code J is only available with conduit connections option E.  
 K    Transient Mist Remediation  
   Approval code J is only available with conduit connections option E.  
 L    Transient Bubble Remediation  
   Approval code J is only available with conduit connections option E.  
 M    Fuel consumption  
   Approval code J is only available with conduit connections option E.  
 Q    Transient Bubble Remediation and petroleum measurement  
   Approval code J is only available with conduit connections option E.  
 R    Piece-wise linearization for gas  
   Approval code J is only available with conduit connections option E.  
 X    ETO software option 1  
   Requires factory code X  
 
 Code    Software options 1 �?only available with mounting code H (1)
All concentration measurement or petroleum measurement options are automatically programmed by the CDM / FDM.
 B    CDM density meter connection - IIC ATEX & IECEx rating  
   Not available with display code 2  
 C    FDM density meter connection - IIC ATEX & IECEx rating  
   Not available with display code 2  
 D    FVM viscosity meter connection - IIC ATEX & IECEx rating  
   Not available with display code 2  
 E    CDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings  
   Not available with display code 5  
 F    FDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings  
   Not available with display code 5  
 H    FVM viscosity meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings  
   Not available with display code 5  
 Software 2  
 Code    Software options 2 for Model 2700 �?available with all mounting codes  
 Z    No software options 2  
 W    Weights & measures custody transfer  
   Only available with output codes A, B, C, 2 or 3; Not available with Software Options 1 codes C or D  
 X    ETO software option 2; requires factory code X  
 Code    Software options 2 for Model 2700 �?available only with mounting codes R, I, B, E, C, or M and P  
 C    Smart Meter Verification  
   Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.  
 D    Weights & measures custody transfer and Smart Meter Verification  
   Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.  
 A    Regulatory Control Suite: Standard function blocks plus 1 PID block  
   Available with output codes E and N only  
 F    Regulatory Control Suite: Standard function blocks plus 1 PID block & Smart Meter Verification  
   Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not available with mounting option I, B, E, C, or P  
 S    Safety Certification of 4-20 mA output per IEC 61508  
   Available with Output codes A, B, C, and D only  
 Code    Software options 2 for Model 2700 �?available only with mounting codes R, I, B, E, C, or M and P  
 V    Safety Certification per IEC 61508 with Smart Meter Verification  
   Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not available with mounting option I, B, E, C, or P; Not available with approval options S or T with conduit connections L or M  
 Factory  
 Code    Factory options for Model 2700  
 Z    Standard product  
 X    ETO product  
 Add on Options  
 Code    Add on options for Model 2700 �?Available only for output code 2, 3, or 4  
 PI    Model 775 integrally mounted at the factory, wiring completed in the field  
   Not available with approvals J, T, or S; Add on option PI is not available with Output code 4 and approval code A. CSA requires installation with a poured conduit seal or stopping box between the transmitter and the 775 Thum.  
 NI    Model 775 not installed, installation and wiring completed in the field  
   Not available with approvals J, T, or S  
 Code    Add on options for Model 2700 �?for mounting code R, B, E, H, M, P, or C  
 PK    2-inch pipe mount U-bolt kit for electronics  
 Code    Add on options for Model 2700 �?Country‐specific approval (select one from the following if approval code G is selected)  
 R1    EAC Zone 2 - Hazardous Area Approval - Increased safety terminal compartment (Exe)  
 R2    EAC Zone 1 - Hazardous Area Approval - Flameproof terminal compartment  
 R3    EAC Zone 2 - Hazardous Area Approval - Energy limited device (ExnA )  
   Sensor connections will be intrinsically safe without additional barrier  
 B1    INMETRO Zone 1 - Hazardous Area Approval - Increased safety terminal compartment N/C  
 B2    INMETRO Zone 1 - Hazardous Area Approval - Flameproof terminal compartment  
 B3    INMETRO Zone 2 - Hazardous Area Approval  
   Sensor connections will be intrinsically safe without additional barrier  
Mass Flow & Density Transmitter 

Model: 2700-R.1.1.E.F.F.E.Z.A.Z  

Make : Rosemount

Qty : 1 No





Copyright©2006-2013 Leda Greenpower Beijing ICP Reg. No: 10010978
   Fax:0086-10-84161062  E-mail:
[email protected]
[email protected]   Google