ROSEMOUNT PRESSURE TRANSMITTER 3051TG3A2B21AS5B4E8M4Q4
SN |
DESCRIPTION |
Qty |
1 |
VALVE; SOLENOID (20 CB), GE P/N 279A1358 P001. MAKE: LAURENCE, USA. TYPE: 3309VWA1208SDC. VENDER CODE VC-49259. DWG-4538-D .VOLTAGE: 130 VDC. PRESSURE RATING: 183 PSI. SIZE: 1 INCH PIPE. |
4 |
2 |
POWER QUALITY METER ;PQMII; MAKE: GE. ORDER CODE: PQMII-T20-C-A. CONTROL POWER: 90-300 VDC, 70-265@ VAC 50/60 HZ. MAX. CONTACT RATIN G: 250 VAC, 8A RESISTIVE. FIRMWARE: 73D224C4.000. COMMUNICATION PORTS: TWO RS485 PORT & ONE RS232 PORT. ANALOG OUTPUTS: FOUR ISOLATE D ANALOG OUTPUTS, 0-20 MA AND 4-20 MA ASSIGNABLE TO ALL MEASURED PARAMETERS. ANALOG INPUTS: 4-20 MA ANALOG INPUT. RELAY OUTPUTS: THR EE PROGRAMMABLE OUTPUT RELAYS. SWITCH INPUTS: 4 PROGRAMMABLE SWITCH INPUTS. |
1 |
3 |
PRESSURE TRANSMITTER; MAKE: ROSEMOUNT; MODEL: 3051T IN-LINE; ORDER CODE : 3051TG3A2B21AS5B4E8M4Q4; SUITABLE FOR 96QP-1, 96HD-1, 96 H G-1, 96 HL-1, 96 FL-1,96 WX-1 & 96WC 0652; PRESSURE TYPE: GAGE; PRESSURE RANGE: -14.7 TO 800 PSI (-1.01 TO 55.15 BAR); TRANSMITTER O UTPUT: 4�?SPAN lang=EN-US>20 MA WITH DIGITAL SIGNAL BASED ON HART PROTOCOL; PROCESS CONNECTION STYLE: 1/2�?SPAN lang=EN-US>14 NPT FEMALE; ISOLATING DIAPHRAGM: 316L SS T; SENSOR FILL FLUID: SILICONE; HOUSING MATERIAL: ALUMINUM; INTEGRAL ASSEMBLY: ASSEMBLE TO ROSEMOUNT 306 INTEGRAL MANIFOLD; MOUNTING BRACKET: BRACKET FOR 2-IN. PIPE OR PANEL MOUNTING, ALL SST; PRODUCT CERTIFICATIONS : ATEX FLAMEPROOF AND DUST CERTIFICATION; CALIBR ATION CERTIFICATION: CALIBRATION CERTIFICATE; DISPLAY AND INTERFACE OPTIONS: LCD DISPLAY WITH LOCAL OPERATOR INTERFACE |
3 |
4 |
PRESSURE TRANSMITTER; MAKE: ROSEMOUNT; MODEL: 3051T IN-LINE; ORDER CODE : 3051TG4A2B21AS5B4E8M4Q4; SUITABLE FOR 96 FL-4, 96 HQ, 96 H Q-1; PRESSURE TYPE: GAGE; PRESSURE RANGE: -14.7 TO 4000 PSI (-1.01 TO 275.79 BAR); TRANSMITTER OUTPUT: 4�?SPAN lang=EN-US>20 MA WITH DIGITAL SIGNAL B ASED ON HART PROTOCOL; PROCESS CONNECTION STYLE: 1/2�?SPAN lang=EN-US>14 NPT FEMALE; ISOLATING DIAPHRAGM: 316L SST; SENSOR FILL FLUID: SILICONE; HOUS ING MATERIAL: ALUMINUM; INTEGRAL ASSEMBLY: ASSEMBLE TO ROSEMOUNT 306 INTEGRAL MANIFOLD; MOUNTING BRACKET: BRACKET FOR 2-IN. PIPE OR PANEL MOUNTING, ALL SST; PRODUCT CERTIFICATIONS : ATEX FLAMEPROOF AND DUST CERTIFICATION; CALIBRATION CERTIFICATION: CALIBRATION CER TIFICATE; DISPLAY AND INTERFACE OPTIONS: LCD DISPLAY WITH LOCAL OPERATOR INTERFACE |
2 |
5 |
PRESSURE TRANSMITTER; MAKE: ROSEMOUNT; MODEL: 3051T IN-LINE; ORDER CODE: 3051TG2A2B21AS5B4E8M4Q4P1Q15; SUITABLE FOR 96 QT-2 & 96 QA- 2; PRESSURE TYPE: GAGE; PRESSURE RANGE: -14.7 TO 150 PSI (-1.01 TO 10.34 BAR); TRANSMITTER OUTPUT: 4�?SPAN lang=EN-US>20 MA WITH DIGITAL SIGNAL BASED ON HART PROTOCOL; PROCESS CONNECTION STYLE: 1/2�?SPAN lang=EN-US>14 NPT FEMALE; ISOLATING DIAPHRAGM: 316L SST; SENSOR FILL FLUID: SILICONE; HOUSING MATERIAL: ALUMINUM; INTEGRAL ASSEMBLY: ASSEMBLE TO ROSEMOUNT 306 INTEGRAL MANIFOLD; MOUNTING BRACKET: BRACKET FOR 2-IN. PIPE OR PANE L MOUNTING, ALL SST; PRODUCT CERTIFICATIONS : ATEX FLAMEPROOF AND DUST CERTIFICATION; CALIBRATION CERTIFICATION: CALIBRATION CERTIFI CATE; DISPLAY AND INTERFACE OPTIONS: LCD DISPLAY WITH LOCAL OPERATOR INTERFACE; PRESSURE TESTING: HYDROSTATIC TESTING WITH CERTIFICA TE; NACE CERTIFICATE: CERTIFICATE OF COMPLIANCE TO NACE MR0175/ISO15156 FOR WETTED MATERIALS |
2 |
6 |
PRESSURE TRANSMITTER; MAKE: ROSEMOUNT; MODEL: 3051T IN-LINE; ORDER CODE : 3051TG3A2B21AS5B4E8M4Q4P1Q15; SUITABLE FOR 96 FG-4, 96 AB- 1; PRESSURE TYPE: GAGE; PRESSURE RANGE: -14.7 TO 800 PSI (-1.01 TO 55.15 BAR); TRANSMITTER OUTPUT: 4�?SPAN lang=EN-US>20 MA WITH DIGITAL SIGNAL BASED ON HART PROTOCOL; PROCESS CONNECTION STYLE: 1/2�?SPAN lang=EN-US>14 NPT FEMALE; ISOLATING DIAPHRAGM: 316L SST; SENSOR FILL FLUID: SILICONE; HOUSING MATERIAL: ALUMINUM; INTEGRAL ASSEMBLY: ASSEMBLE TO ROSEMOUNT 306 INTEGRAL MANIFOLD; MOUNTING BRACKET: BRACKET FOR 2-IN. PIPE OR PANE L MOUNTING, ALL SST; PRODUCT CERTIFICATIONS : ATEX FLAMEPROOF AND DUST CERTIFICATION; CALIBRATION CERTIFICATION: CALIBRATION CERTIFI CATE; DISPLAY AND INTERFACE OPTIONS: LCD DISPLAY WITH LOCAL OPERATOR INTERFACE; PRESSURE TESTING: HYDROSTATIC TESTING WITH CERTIFICA TE; NACE CERTIFICATE: CERTIFICATE OF COMPLIANCE TO NACE MR0175/ISO15156 FOR WETTED MATERIALS; |
2 |
7 |
Vibration Sensor, Model No: 5485C - 008, GE P/No: 329A3529P1, Make: Metrix Instrument Co., USA, Certificate: OEM and Country of Origin Certificate, Warranty: One year. |
5 |
8 |
2. PH CARTRIDGE SENSOR, MAKE: ABB, AP 100 SERIES, CARTRIDGE TYPE:AP 102BAYONET, SENSOR TYPE: 10X/1 WITH THREE METER CABLE FOR THE MODEL:7670-180, PROCESS CONNECTION ¼ INCH NPT.SENSORS,OFFSET PORTED IN LINE SYSTEM WITH OFFSET PORTED FLOW CELL |
2 |
9 |
FLAME DETECTOR FOR AUXILIARY COMPARTMENT, MAKE: DETECTOR ELECTRONICS CORPORATION (DET-TRONICS), MODEL: X3301, SENSOR: MULTI SPECTRU M IR (IR3), TEMPERATURE RANGE: -55°C TO 125°C, OPERATING VOLTAGE: 24VDC NOMINAL (18-30), HUMIDITY: UP TO 95% NON- CONDENSING, RESPO NSE TIME: 3 SEC, POWER REQUIREMENTS: 4 WATTS, OUTPUTS: ANALOGUE 4-20 MA / DIGITAL RELAY OUTPUT. PROTECTION: IP66. |
3 | |
|
|