RELAY [R.P.R] 10A, 125VAC, 1250W, 900/910 SERIES,
[RAPID PRESSURE RISE], P/NO: USA- 3535878, 3646970, CANADA-907668 |
QUALITROL® 900/910 RPRR Rapid pressure rise relays Protection and detection of dangerous sudden pressure changes • 100% factory calibrated and tested to ensure performance • Multiple mounting and calibration options for gas or oil applications • From the original creator of mechanical rapid pressure rise relays Description Patented mechanical device for detection of sudden pressure events based on the rate of pressure rise and safe limits established by transformer manufacturers. When a dangerous pressure rise has been detected, the QUALITROL rapid pressure rise relay (RPRR) will change state. This can be used as an alarm or trip signal to minimize the potential of transformer tank damage. Application For transformer and other electrical apparatus protection. Can be used in both oil (QUALITROL 900) or gas (QUALITROL 910) space of a transformer. Product Summary
Protection and detection of |
• Devices calibrated to quickly alarm or trip during | dangerous sudden pressure changes rapid pressure rise changes (see response curves below) • Actuation only occurs based on rate of pressure rise and will not occur under normal pressure variations caused by temperature change and vibration • Can be subjected to full vacuum or 20 PSI positive pressure without damage • Standard operation from -40 to 180ºF ( -40 to 82ºC) • Special units available for operation at -67ºF (-55ºC) ` 100% factory calibrated and • Units are serialized and calibration records are maintained tested to ensure performance • Factory tested for switch (contact) performance and response time • Field test kit available for simple GO/NO-GO test to assure proper functionality of the device Multiple mounting and calibration • Flange or thread mounting options available for both vertical or options for gas or oil applications horizontal mounting • Models calibrated for proper response in gas or oil space applications (see response curves below) From the original creator of • Original creator of patented bellows technology for mechanical mechanical rapid pressure rise relays rapid pressure rise detection • Over 25 years of experience and refnement in rapid pressure rise protection with greater than 100,000 units installed RPRR response curves 900 Series Response Limits 910 Series Response Limits
Seal-in relay (909-300) • Latching relay to “seal-in�?momentary switch actuations common with detection of rapid pressure rise events • Confgurable for VAC or VDC • Two output relays • LED lights to indicate active status and actuation • Low profle • Redundant make/break circuit requirement protects against false trips due to damaged wiring • UL certifed for use in hazardous locations (Class 1, Div 2) Factory test fxture (FIX-601) • Mimics the calibration and verifcation testing performed at the factory for all QUALITROL RPRRs • Designed for use in repair shops and transformer manufacturing plants • Built in LED indicator lamps show test status and results Field test kit (KIT-013-1) • Easy feld test kit for “go/no-go�?testing of all QUALITROL RPRRs • Rugged carrying case • Setup and test instructions in case • Power supply and other required components provided in kit
|