MOISTUREMETER CELL PANAMETRICS 167002-PR WITH 2PCS IC PDRY06 , PDRY04
Supplier: GE
This Panametrics aluminum oxide moisture sensor probe measures moisture concentration in gases and non-aqueous liquids from trace to ambient levels. It is designed to be used in conjunction with all Panametrics moisture analyzers for industries including: • Petrochemical • Natural gas • Industrial gas • Semiconductor • Furnace gas/heat treating • Power generation • Air dryer • Pharmaceutical • Aerospace Applications Features • Intrinsically safe when used in conjunction with certified electronics or zener barriers • Superior sensitivity, response speed and calibration stability • Optional temperature sensor • Calibrations traceable to National Institute of Standards and Technology (NIST) or National Physical Lab U.K. (NPL) • Designed for in situ applications or in conjunction with sample conditioning systems • True absolute humidity sensor • Wide dynamic range
M Series Specifications Moisture Probe Intrinsic Safety Intrinsically safe when connected to a Panametrics Moisture Series analyzer, PM880 portable hygrometer or intrinsically safe barriers in accordance with the user’s manual. M Series moisture probe: BAS01ATEX1096X II 1 G EEx ia IIC T4 (-20°C to +80°C), and CSA C US Class I, Division 1, Groups A,B,C&D T4, LR44204-23 European Compliance Complies with EMC Directive 89/336/EEC and PED 97/23/EC for DN<25 Type Aluminum oxide moisture sensor Calibration Each probe is individually computer calibrated against known moisture concentrations, traceable to NIST or NPL. Dew/Frost Point Calibration Ranges • Overall capability: 140°F to -166°F (60°C to �?10°C) by request • Standard calibration range: 68°F to -112°F (20°C to �?0°C) with data to -166°F (-110°C) • Ultralow calibration range: -58°F to -148°F (-50°C to �?00°C) with data to -166°F (-110°C) Accuracy • ±3.6°F (±2°C) in range of 140°F to -85°F (60°C to �?5°C) • ±5.4°F (±3°C) in range of -86°F to -166°F (-66°C to 110°C) Repeatability • ±0.9°F (±0.5°C) in range of 140°F to -85°F (60°C to �?5°C) • ±1.8°F (±1.0°C) in range of -86°F to -166°F (�?6°C to �?10°C) Temperature • Operating: -166°F to 158°F (�?10°C to 70°C) • Storage: Maximum 158°F (70°C) Operating Pressure (Dependent on Mount) • Flange process connection (M1): 5 :Hg to 75 psig (6 bar) • Threaded process connection (M2): 5 :Hg to 5000 psig (345 bar) Flow Range • Gases: Static to 10,000 cm/s linear velocity at 1 atm • Liquids: Static to 10 cm/s linear velocity at density of 1 g/cc Response Time Less than five seconds for 63% step change in moisture content in either wet-up or dry-down cycle Consult factory for specifications of other moisture probes available for special applications. Input Voltage 1 VAC, 77 Hz Impedance Range 50 kS to 2 MS depending on water vapor Limited Warranty • Calibration: Six months from delivery • Materials and workmanship: One year from delivery Optional Temperature Sensor Type Nonlinear negative temperature coefficient (NTC) thermistor (resultant temperature linearized by microprocessor) Operating Range �?2°F to 158°F (�?0°C to 70°C) Accuracy ±0.9°F (±0.5°C) overall Response Time (Maximum) 1 second in well-stirred oil or 10 seconds in still air for a 63% step change in increasing or decreasing temperature |