M/N:AT868
Specification:Auto Tracking Window, 85to265VAC,50/60HZ
Accuracy:±0.5%, Output: 4~20mA/Pulse
Small bore sensor(below 2In):Pair of UTXDR with Clamping,
a transmitter-receiver part, Cable:7m(2pair), 2flying lead for use with AT868
MAKER:GE PANAMETRICS
Applications The AquaTrans AT600 flowmeter is a complete ultrasonic system for the measurement of: • Potable Water • Wastewater • Sewage • Discharge water • Treated water • Cooling and heating water • Irrigation water • Other industrial fluids Features and Benefits • Economical non-intrusive flow measurement • Extremely simple setup and installation • Suitable for a wide range of pipe sizes and materials • Suitable for lined pipes • Velocity, volumetric, and totalized flow outputs • Clamp-on installations • Permanent solid couplant for clamp-on applications.
Overall Operation and Performance Fluid Types Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles Flow Measurement Patented Correlation Transit-TimeTM model Pipe Sizes • 2 to 24in (50 to 600mm) standard • Other sizes available upon request Pipe Materials All metals and most plastics. Consult GE for concrete, composite materials, and highly corroded or lined pipes. Accuracy • ±1% of reading in application • ±0.5% in field calibration Installation assumes a fully developed, symmetrical flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run). Final installation accuracy is a function of multiple factors including fluid, temperature range, pipe centricity, and other. Calibration All meters are water calibrated and delivered with a traceable calibration certificate. Repeatability ±0.2% of reading Range (Bidirectional) -40 to 40 ft/s (-12.19 to 12.19 m/s) Rangability (Overall) 400:1 Measurement Parameters Velocity, Volumetric, and Totalized Flow Electronics Enclosure Epoxy-coated aluminum weatherproof Type 4X/IP67 Dimensions 6.6 x 5.0 x 2.4in (168 x 128 x 61mm) Weight: 3.5 lbs/1.5kg Channels One channel Display Graphic LCD (128 x 64 pixels) Keypad Six-button keypad, for full functionality operation Error Display Indicator • Green or red light Power Supplies • Standard: 85 to 265 VAC, 50/60 Hz • Optional: 12 to 28 VDC, ± 5% Power Consumption 10 Watts in rush 5 Watts normal operation Operating Temperature -4°F to 131°F (�?0°C to 55°C) Storage Temperature �?0°F to 158°F (�?0°C to 70°C) Outputs (Based on Configuration) • 4-20mA (24VDC powered, 600Ω maximum load, 1500 VDC Isolation) • Frequency, Pulse, Alarm (Passive output, 100VDC, 1A/1W maximum, 1500 VDC isolation) • HART (FSK modulation, Category Flow, Protocol Version 7.5, Device Revision 2, MFG ID 157, Device Type Code 127, Number of device variables 34) • Modbus/RS485 (Half-duplex, 1500 VDC Isolation) Analog outputs Namur NE 43 compliant Certification CE, UL, CSA, MCert approval pending Clamp-On Ultrasonic Flow Transducers Temperature Ranges • Standard: -40°F to 302°F (-40°C to 150°C) • Optional: -328°F to 752°F (-200°C to 400°C) See specific transducer for exact temperature range. Mounting Fixture Anodized aluminum with stainless steel strapping Couplant Solid couplant standard Rating Standard: General purpose (IP66 or IP68) See transducer for exact rating
Ordering Information |
|
|
|
|
|
|
|
|
|
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
|
Z |
AT6 |
|
|
|
|
|
|
|
|
|
|
|
Model Clamp-on liquid ultrasonic flowmeter consisting of an AT600, transducers, clamping fixture, transducer cable and couplant |
|
C1 |
|
|
|
|
|
|
|
|
|
|
Clamp-on System Single-channel clamp-on system |
|
|
CR05 CR10 AT20 |
|
|
|
|
|
|
|
|
Transducer System C-RS transducers, 0.5 MHz, IP66 (Typical 8 to 24 in/200 to 600 mm) C-RS transducers, 1 MHz, IP66 (Typical pipe sizes of 4 to 12 in/100 to 300 mm) C-AT transducers, 2 MHz, IP68 (Typical pipe sizes of 2 to 6 in/50 to 150 mm) |
|
|
|
<> |
|
|
|
|
|
|
|
|
Pipe Size Nominal outer diameter |
|
|
|
|
IN MM |
|
|
|
|
|
|
|
Pipe Units Inches Millimeters |
|
|
|
|
|
1 2 3 4 7 |
|
|
|
|
|
Cable Length 10 feet (3 meters) of transducer cable 25 feet (7.5 meters) of transducer cable 50 feet (15 meters) of transducer cable 100 feet (30 meters) of transducer cable 300 feet (90 meters) of transducer cable |
|
|
|
|
|
|
1 2 |
|
|
|
|
|
AT Power 85 to 265 VAC 12 to 28 VDC |
|
|
|
|
|
|
|
A H M |
|
|
|
|
Analog & Digital Output 4-20 mA analog output only 4-20 mA analog output with HART 4-20 mA analog output and Modbus |
|
|
|
|
|
|
|
|
AA AF AT FF FT TT |
|
|
Discrete Output Two Alarm Contacts One Alarm Contact and one Frequency Output One Alarm Contact and one Totalizer (Pulse) Output Two Frequency Outputs One Frequency Output and One Totalizer (Pulse) Output Two Totalizer (Pulse) Outputs |
|
|
|
|
|
|
|
|
|
01 02 03 04 05 06 07 08 09 |
Language English German French italian Spanish Portuguese Russian Japanese Chinese |
|
|
|
|
|
|
|
|
|
|
M E |
|
Default Units Metric English |
|