Foxboro Differential Pressure Transmitter 143DP-A1SS1V1N1EA4F-ASF
Your Item #32 / 6455256619 Differential Pressure Transmitter 143DP-A1SS1V1N1EA4F-ASF Product discontinued, replaced with IDP10: Intelligent Differential Pressure Transmitter IDP10-DLLA01F-L1T IDP10 FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent; digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable LL STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, silicone fill fluid A SPAN LIMITS: 0.12 and 7.5 kPa; 0.5 and 30 inH2O; 1.2 and 75 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order Alternatively you may consider the all new Value Differential Pressure Transmitter IDP05S (without FoxCom!): |
Item 1.2 Value Differential Pressure Transmitter IDP05S-TLLB01AA-L1T IDP05S FUNCTION: Measures the difference between two pressures and transmits a proportion or sqaure root (flow) electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LL STRUCTURE CODE: LP1 direct mount; 316 SS process cover, 316L SS sensor, silicone fill fluid B SPAN LIMITS: 0.5 and 200 inH2O; 0.12 and 50 kPa; 1.2 and 500 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, bot sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, II 1 GD EEx ia IIC, Zone 0 L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Your Item #33 Differential Pressure Transmitter 143DP-B1SS1V1N1EA4F-ASF Product discontinued, replaced with IDP10: Item 2.1 Intelligent Differential Pressure Transmitter IDP10-DLLC01F-L1T IDP10 FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent; digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable LL STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, silicone fill fluid C SPAN LIMITS: 7 and 210 kPa; 28 and 840 inH2O; 70 and 2100 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order Alternatively you may consider the all new Value Differential Pressure Transmitter IDP05S (without FoxCom!): |
Item 2.2 Value Differential Pressure Transmitter IDP05S-TLLC01AA-L1T IDP05S FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LL STRUCTURE CODE: LP1 direct mount; 316 SS process cover, 316L SS sensor, silicone fill fluid C SPAN LIMITS: 2.5 and 1000 inH2O; 0.62 and 250 kPa; 6.22 and 2500 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, II 1 GD EEx ia IIC, Zone 0 L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Your Item #34 / 6455550159 Differential Pressure Transmitter 143DP-C1SS1V1N1EA4F-ASF Product discontinued, replaced with IDP10: Item 3.1 Intelligent Differential Pressure Transmitter IDP10-DLLD01F-L1T IDP10 FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent; digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable LL STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, silicone fill fluid D SPAN LIMITS: 0.07 and 2.1 MPa; 10 and 30 psi; 0.7 and 21 bar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order Alternatively you may consider the all new Value Differential Pressure Transmitter IDP05S (without FoxCom!): |
Item 3.2 Value Differential Pressure Transmitter IDP05S-TLLD01AA-L1T IDP05S FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LL STRUCTURE CODE: LP1 direct mount; 316 SS process cover, 316L SS sensor, silicone fill fluid D SPAN LIMITS: 3.75 and 300 psi; 0.026 and 2.07 MPa; 0.26 and 20.7 bar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, II 1 GD EEx ia IIC, Zone 0 L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Item 4 Your Item #35 Gauge Pressure Transmitter 141GP-AS1N2N1EA4F-ASF Product discontinued, replaced with IGP20: Item 4.1 Intelligent Gauge Pressure Transmitter IGP20-D23B21F-L1T IGP20 FUNCTION: Measures pressure and transmits a proportional electrical signal in either analog or digital mode. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable 23 STRUCTURE CODE: 316 SS Hi-side cover, 316L SS sensor, fluorinert fill fluid B SPAN LIMITS: 0.87 and 50 kPa, 3.5 and 200 inH2O, 8.7 and 500 mbar 2 PROCESS CONNECTOR: 1/2 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IGP05S (without FoxCom!): |
Item 4.2 Value Gauge Pressure Transmitter IGP05S-TLMC1AA-L1F2T IGP05S FUNCTION: Measures pressure and transmits a proportional electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LM STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, fluorinert fill fluid C SPAN LIMITS: 0.09 and 36.1 psi; 0.62 and 250 kPa 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, Ex ia IIC L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover F2 OPTIONAL MODEL SUFFIX INCLUDED: Biplanar process connector type 1/2 NPT T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Item 5 Your Item #36 1 Gauge Pressure Transmitter 141GP-BS1N2N1EA4F-ASF Product discontinued, replaced with IGP20: Item 5.1 Intelligent Gauge Pressure. Transmitter IGP20-D23C21F-L1T IGP20 FUNCTION: Measures pressure and transmits a proportional electrical signal in either analog or digital mode. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable 23 STRUCTURE CODE: 316 SS Hi-side cover, 316L SS sensor, fluorinert fill fluid C SPAN LIMITS: 0.007 and 0.21 MPa, 1 and 30 psi, 0.07 and 2.1 bar or kg/cm2 2 PROCESS CONNECTOR: 1/2 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IGP05S (without FoxCom!) |
Item 5.2 Value Gauge Pressure Transmitter IGP05S-TLMC1AA-L1F2T IGP05S FUNCTION: Measures pressure and transmits a proportional electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LM STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, fluorinert fill fluid C SPAN LIMITS: 0.09 and 36.1 psi; 0.62 and 250 kPa 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, Ex ia IIC L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover F2 OPTIONAL MODEL SUFFIX INCLUDED: Biplanar process connector type 1/2 NPT T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Item 6 Your Item #37 / 6459600159 1 Gauge Pressure Transmitter 141GP-CS1N2N1EA4F-ASF Product discontinued, replaced with IGP20: Item 6.1 Intelligent Gauge Pressure Transmitter IGP20-D23D21F-L1T IGP20 FUNCTION: Measures pressure and transmits a proportional electrical signal in either analog or digital mode. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?20 mA, configurable 23 STRUCTURE CODE: 316 SS Hi-side cover, 316L SS sensor, fluorinert fill fluid D SPAN LIMITS: 0.07 and 2.1 MPa, 10 and 300 psi, 0.7 and 21 bar or kg/cm2 2 PROCESS CONNECTOR: 1/2 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IGP05S (without FoxCom!): |
Item 6.2 Value Gauge Pressure 1 net Transmitter IGP05S-TLMD1AA-L1F2T IGP05S FUNCTION: Measures pressure and transmits a proportional electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?20 mA LM STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, fluorinert fill fluid D SPAN LIMITS: 3.75 and 300 psi; 26 and 2070 kPa 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, Ex ia IIC L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover F2 OPTIONAL MODEL SUFFIX INCLUDED: Biplanar process connector type 1/2 NPT T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Item 7 Your Item #38 1 Gauge Pressure Transmitter 141GP-DS1N2N1EA4F-ASF Product discontinued, replaced with IGP20: Item 7.1 Intelligent Gauge Pressure IGP20-D23E21F-L1T IGP20 FUNCTION: Measures pressure and transmits a proportional electrical signal in either analog or digital mode. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?20 mA, configurable 23 STRUCTURE CODE: 316 SS Hi-side cover, 316L SS sensor, fluorinert fill fluid E SPAN LIMITS: 0.7 and 21 MPa, 100 and 3000 psi, 7 and 210 bar or kg/cm2 2 PROCESS CONNECTOR: 1/2 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental tag Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IGP05S (without FoxCom!): |
Item 7.2 Value Gauge Pressure Transmitter IGP05S-TLMF1AA-L1F2T IGP05S FUNCTION: Measures pressure and transmits a proportional electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA LM STRUCTURE CODE: LP1; 316 SS process cover, 316L SS sensor, fluorinert fill fluid F SPAN LIMITS: 165 and 5000 psi; 1.1 and 34.5 MPa 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing AA ELECTRICAL SAFETY: ATEX intrinsically safe, Ex ia IIC L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover F2 OPTIONAL MODEL SUFFIX INCLUDED: Biplanar process connector type 1/2 NPT T OPTIONAL MODEL SUFFIX INCLUDED: Supplemental customer tag (stainless steel tag wired onto transmitter) Calibrated Range: to be announced by customer upon award of order Tag No. Labeling: to be announced by customer upon award of order |
Item 8 Your Item #43 / 6461150159 5 Temperature Transmitter RTT20-T1SNKEA-A1L3M1 Product discontinued, replaced by RTT15S: Item 8.1 Optical Temperature Transmitter RTT15S-T1SA1KNAAA-L1M1 RTT15S FUNCTION: Optical temperature transmitter OTTPlus T OUTPUT: 4 �?20 mA with HART digital communications 1 INPUT/OUTPUT CONFIGURATION: Configured for single sensor input SA HOUSING AND SENSOR MOUNT: Housing without sensor 1 HOUSING TYPE: Aluminum, 1/2 female NPT conduit connection K INPUT MEASUREMENT TYPE:Thermocouple, type K NA THERMOWELL ASSEMBLED TO HOUSING: No well or well supplied seperately AA HAZARDOUS AREA CERTIFICATIONS: ATEX intrinsic safe, Ex ia & Ex ic L1 OPTIONAL SELECTION: Integral display/optical configurator M1 OPTIONAL SELECTION: Mounting set painted steel Calibrated Range: to be announced by customer upon award of order |
Item 9 Your Item #44 / 6455500309 Intelligent Gauge Pressure Transmitter IGP10-D22D1F-M1L1 IGP10 FUNCTION: Measures pressure and transmits a proportional electrical signal. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable 22 STRUCTURE CODE: 316L SS process connection, 316L SS diaphragm, silicone fill fluid, 1/2 NPT external & 1/4 NPT internal thread connection type D SPAN LIMITS: 0.07 and 2.1 MPa, 100 and 300 psi, 0.7 and 21 bar or kg/cm2 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, Groups E, F & G; and Class III, Division 1. M1 OPTIONAL MODEL SUFFIX INCLUDED: Painted steel mounting bracket with plated steel bolts L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IGP05S (without FoxCom!): |
Item 9.1 Value Gauge Pressure Transmitter IGP05S-T22E1FA-M1L1 IGP05S FUNCTION: Measures pressure and transmits a proportional electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?20 mA 22 STRUCTURE CODE: 316L SS process connection, 316L SS diaphragm, silicone fill fluid, 1/2 NPT external & 1/4 NPT internal thread connection type E SPAN LIMITS: 5 and 2000 psi; 0.034 and 13.8 MPa 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing FA ELECTRICAL SAFETY: FM Classes I, II and III, Division 1 intrinsically safe AEx ia IIC M1 OPTIONAL MODEL SUFFIX INCLUDED: Painted steel mounting bracket with plated steel bolts L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover Calibrated Range: to be announced by customer upon award of order |
Item 10 Your Item #45 / 6455700159 2 net 2'329.80 Intelligent Differential Pressure Transmitter IDP10-D22B01F-M1L1 IDP10 FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. D ELECTRONICS VERSION AND OUTPUT SIGNAL: Intelligent, Digital FoxCom or 4 �?SPAN lang=EN-US> 20 mA, configurable 22 STRUCTURE CODE: 316 SS process cover, 316L SS sensor, silicone fill fluid B SPAN LIMITS: 0.87 and 50 kPa; 3.5 and 200 inH2O; 8.7 and 500 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing F ELECTRICAL SAFETY: FM intrinsically safe for Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1. Also Class I, Division 2, Groups A, B, C &D; Class II, Groups F & G; and Class III, Division 2. Explosionproof for Class I, Division 1, Groups B, C & D; dust-ignitionproof for Class II, Division 1, to be announced by customer upon award of order Groups E, F & G; and Class III, Division 1. M1 OPTIONAL MODEL SUFFIX INCLUDED: Painted steel mounting bracket with plated steel bolts L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover Calibrated Range: to be announced by customer upon award of order Alternatively you may consider the all new Value Gauge Pressure Transmitter IDP05S (without FoxCom!): |
Item 10.1 Value Differential Pressure 2 net Transmitter IDP05S-T22B01FA-M1L1 IDP05S FUNCTION: Measures the difference between two pressures and transmits a proportional or sqaure root (flow) electrical signal. Accuracy expressed as percentage of span. T ELECTRONICS VERSION AND OUTPUT SIGNAL: HART & 4 �?SPAN lang=EN-US> 20 mA 22 STRUCTURE CODE: 316 SS process cover, 316L SS sensor, silicone fill fluid B SPAN LIMITS: 0.5 and 200 inH2O; 0.12 and 50 kPa; 1.2 and 500 mbar 0 PROCESS CONNECTOR: No connectors, both covers tapped for 1/4 NPT 1 CONDUIT CONNECTION AND HOUSING MATERIAL: 1/2 NPT conduit connection, both sides, Aluminum housing FA ELECTRICAL SAFETY: FM Classes I, II and III, Division 1 intrinsically safe AEx ia IIC M1 OPTIONAL MODEL SUFFIX INCLUDED: Standard style painted steel mounting bracket with plated steel bolts L1 OPTIONAL MODEL SUFFIX INCLUDED: Digital display, pushbuttons and window cover Calibrated Range: to be announced by customer upon award of order |
|
|
|