DETECTOR, MULTISPECTRAL IR FLAME DETECTOR, MODEL: X3301-S-4N-13-W-1
Specification :
DETECTOR
TYPE MULTISPECTRAL IR FLAME DETECTOR, 4 PORT, 3/4" NPT, 316SS
MANUFACTURER DET-TRONICS / NUOVO PIGNONE
MODEL, EQUIPMENT X3301-S-4N-13-W-1
ADD REQRMTS FM/CSA/ATEX/CE/IECEx, DIVISION/ZONE Ex d e
DRAWING NUMBER SOM5081389
PART NUMBER X3301-S-4N-13-W-1 / RRO633981311 (old RSO324741211)
POSITION NUMBER 45UV/IR-1/2/3/4/5/6
ADDITIONAL SPECIFICATIONS: 4 PORT, 3/4" NPT, 316SS, RELAY &4-20MA,
AMBIENT TEMP RANGE : --55 TO +125 DEG. C
POWER SUPPLY: 18 -30 VDC ; 4.0 TO 17.0 WATT
EX CERTIFICATION : EX D IIC T5-T6
INGRESS PROTECTION : IP 66/67
HOUSING MOC : SS 316
MAKE: DET-TRONICS
The X3301 is a multispectrum infrared (MIR) flame detector. It provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined with the highest degree of false alarm rejection. The detector has Division and Zone explosionproof ratings and is suitable for use in indoor and outdoor applications. The X3301 contains three IR sensors with their associated signal processing circuitry. The standard output configuration includes fire alarm, fault and auxiliary relays, with an isolated 0 to 20 mA output model with optional HART communication. The detector provides superior performance in applications that are at the extremes, and where background infrared radiation is a normal condition: �?Hangars �?Offshore production platforms �?Offshore production ships �?Refineries �?Production facilities �?Loading racks �?Compressor stations �?Turbine enclosures �?Airport water curtains �?Automotive Painting �?LNG/LPG �?Gas Separation Plants �?Warehousing �?Marine
X3301 TECHNOLOGY FEATURES ▲▲ Complies with FM 3260 ▲▲ EN54 certified ▲▲ Certified SIL 2 capable ▲▲ ATEX Directive compliant ▲▲ Certified performance to multiple fuel types and fire sizes ▲▲ EQP models available ▲▲ Long detection range to carbonaceous fires ▲▲ HART models available ▲▲ FDT/DTM capable ▲▲ Multiple sensitivity levels ▲▲ Maximum false alarm rejection ▲▲ Reliable flame detection with modulated IR background ▲▲ Microprocessor controlled heated optics ▲▲ Calibrated automatic optical check for each sensor eliminates need for testing with external test lamp ▲▲ RFI and EMC Directive compliant ▲▲ Event logging with time and date stamp ▲▲ Integral wiring compartment for ease of installation ▲▲ Operates under adverse weather conditions and in dirty environments BENEFITS ▲▲ Single detector for multiple hydrocarbon fuels ▲▲ Low cost of coverage ▲▲ Ability to detect smaller fires earlier ▲▲ Solid cone of vision to 125 feet for methane ▲▲ Better detection zoning capability ▲▲ Best combination of flame detection and false alarm rejection ▲▲ Low maintenance costs ▲▲ Reliable fault diagnostics ▲▲ Suitable for heavy industrial applications ▲▲ Explosion/flame proof (Ex d) or increased safety installations (Ex d e) in hazardous locations
Operating Voltage 24 Vdc nominal (18 Vdc minimum, 30 Vdc maximum). Maximum ripple is 2 volts peak-to-peak. Power Consumption 4 watts minimum (without heater), 17 watts at 30 Vdc with EOL resistor installed and heater on maximum. Relays Contacts rated 5 amperes at 30 Vdc. Fire Alarm: �?Form C (NO and NC contacts) �?normally de-energized �?latching/non-latching. Fault: �?Form A (NO contacts) �?normally energized �?latching/non-latching. Auxiliary: �?Form C (NO and NC contacts) �?normally energized/de-energized �?latching/non-latching. Current Output 0�?0 mA (± 0.3 mA), with a maximum loop (Optional) resistance of 500 ohms from 18�?9.9 Vdc, 600 ohms from 20�?0 Vdc. Temperature Range Operating: �?0°F to +167°F (�?0°C to +75°C). Storage: �?7°F to +185°F (�?5°C to +85°C). Hazardous location ratings from �?5°C to +125°C. Humidity Range 0 to 95% relative humidity, can withstand 100% condensing humidity for short periods of time. Wiring 16 AWG or 2.5 mm2 shielded cable is recommended. Enclosure Material Copper-free aluminum (painted) or stainless steel (316/CF8M Cast). Conduit Entry Size 3/4 inch NPT or M25. |