1)
- PRESSURE CLASS: 900
- VALVE TYPE: BALL
- REQ. TORQUE OF ACTUATOR FOR 16�?VALVE: 12749 NM
- MAX. START/RATED TORQUE: 17037 NM
- REQ SAFETY FACTOR: 1.3
- CALCULATED SAFETY FACTOR (MAX/RATED): 1.3
- STALL TORQUE: 25555 NM
- OPEN/CLOSE TIMINGS OF ACTUATOR FOR 900# VALVE: 45 SEC
- GEAR BOX RATIO: 372
- DUTY RATING: 15 MINUTES RATED BASED ON A NOMINAL TORQUE OF 33% OF RATED.
- ENCLOSURE: FM-NEMA 3, 4, 4X & 6
- POWER SUPPLY: 400-3-50 +/- 10%
- XP CLASSIFICATION: FM CLASS-I, GR C & D, DIV 1, T4
- IP CLASSIFICATION: 67
- TEMP. RANGE: -30 DEG.C TO + 65 DEG.C
- ELECTRICAL CONDUIT ENTRY: 1 X 1 1/2“NPT + 2 X 1 1/4“NPT (STD)
- CONTROL TYPE: SMART
- STATUS RELAY: 4 SPST
- PAINT SPECIFICATION: STANDARD LPS-130
- COLOR CODE: BLUE RAL 5010 (STANDARD)
2)
- PRESSURE CLASS: 600
- VALVE TYPE: BALL
- REQ. TORQUE OF ACTUATOR FOR 16" VALVE: 12749 NM
- MAX. START/RATED TORQUE: 17037 NM
- REQ. SAFETY FACTOR: 1 3
- CALCULATED SAFETY FACTOR (MAX/RATED): 1.3
- STALL TORQUE: 25555 NM
- OPEN/CLOSE TIMINGS OF ACTUATOR FOR 600# VALVE: 45 SEC
- GEAR BOX RATIO: 372
- DUTY RATING: 15 MINUTES RATED BASED ON A NOMINAL TORQUE OF 33% OF RATED.
- ENCLOSURE: FM-NEMA 3, 4, 4X & 6
- POWER SUPPLY: 400-3-50 +/- 10%
- XP CLASSIFICATION: FM CLASS-1, GR. C & D, DIV1.T4
- IP CLASSIFICATION: 67
- TEMP. RANGE: -30 DEG.C TO + 65 DEG.C
- ELECTRICAL CONDUIT ENTRY: 1 X 1 1/2“NPT + 2 X 1 1/4“NPT (STD)
- CONTROL TYPE: SMART
- STATUS RELAY: 4 SPST
- PAINT SPECIFICATION: STANDARD LPS-130
- COLOR CODE: BLUE RAL 5010 (STANDARD)
Item |
Description |
1 |
AUMA FM (Factory Mutual) Actuator & Gearbox MODEL SAEXFM14.2 ACEXCFM01.2 GS200.3 (214:1) ACTUATOR TORQUE 16573Nm for both 900# & 600# 16" VALVES Flange F35-Y Output drive UN Time: 51.0 seconds Turns 90 ° 53.5 turns/stroke see attached data sheet
Do note in the event of an order Embargoes and Restricted Trade Disclaimer. To satisfy the 'Trade Embargoes and Sanctions' procedures, the following information is required prior to order placement;
Your customer’s full name and trading address. . The end users full name and trading address. . The end users industry (i.e. power, water, petrochemical etc.). . The exact application and intended use of our equipment. This quotation is subject to approval from EC export controls. * DO NOTE DELIVERY WOULD CURRENTLY INCLUDE THE CHRISTMAS SHUTDOWN PERIOD ADDER OF 21ST DECEMBER TO THE 2ND OF JANUARY | |