BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   spare parts   |   Project Financing    |   Equipments   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   Exclusive-Distributor   |   Exchange Link   |   致希望开拓国际市场的中国机电设备企业  

Mail List

E-mail:

spare parts
     Bently Nevada  
     Speedtronic  
     GE-Fanuc  
     GE Druck  
     GE-Multilin  
     GE Panametrics  
     GE Energy  
     Yokogawa  
     FLENDER & Flender Graffenstaden  
     QUALITROL  
     Schneider Electric  
       Telemecanique  
       Gutor Electronic  
       Invensys Foxboro  
       Square D  
       Merlin Gerin  
     Siemens  
     NUOVO PIGNONE  
     ABB-Ontrac ELECTRIC ACTUATOR OF POWER PLANT  
       BALDOR  
     Michell Instruments  
     Vickers  
     Metso  
       Neles  
       Jamesbury  
       Mapag  
       Stonel  
     Blade, Vane for NP, PGT-10, Frame 3, Frame 5  
     Honeywell  
       FEMA  
       MAXON  
       RMG  
     metrix vibration  
     Allen-Bradley  
     KANEKO  
     CCS  
     Deutz-MWM  
     Caterpillar  
     Esco Couplings  
     Woodward  
     NORGREN  
     Parker  
     Foxboro  
     Invensys  
     Asco  
     Swagelok  
     AMERICAN-AIR-FILTER(AAF)  
     HERION  
     Dynisco  
     Pepperl+Fuchs(P+F)  
     Fisher  
     Timken  
     Philadelphia Gear(Western Gear, WesTech)  
     Coaxial Valves  
     DENARDO WIRE & CABLE  
     leslie Laurence Valve  
     Altra motion  
     ATLAS COPCO  
     Colfax Corporation  
       Allweiler  
       Houttuin  
       IMO  
       Tushaco  
       Warren Pumps  
       Zenith  
     ROTORK  
     Emerson  
       Appleton  
       Control Techniques  
       Rosemount  
     MOOG  
     DOLLINGER CORPORATION  
     Viking-Pump  
     Samson  
     KRAISSL  
     KRACHT  
     ECO Gearchem  
     Pratt & Whitney  
     OVAL  
     Roper Pump  
     Rechner Sensors  
     ITT Goulds Pumps  
     Westinghouse  
     Rockwell  
     ENDRESS+HAUSER(E+H)  
     Cummins  
     Dwyer  
     GE-Breaker  
     Masoneilan  
     Omron  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > spare parts > Yokogawa - VF702 Control Bus Interface Card spare parts


Google

VF702 Control Bus Interface Card spare parts

"YOKOGAWA"  V-NET INTERFACE CARD (CONTROL BUS)
MODEL: VF701 (C2ED25039H)
 
General Specifications GS 33Y06H71-31E  Control Bus Interface Card Model VF702  
GENERAL By installing the control bus interface card into the PCI Express slot of the PC/AT compatible computer,
the computer is connected to V net. 
FUNCTION Interface between the PCI Express and V net 
SPECIFICATIONS Connection SpecificationsConnection method: Connect a coaxial cable with Model YCB146,
T-type connector Transmission: 10BASE-2 compliance Connector: BNC connector Max. distance: 185 m
 (When using 10BASE-2 cable only) PCI Express SpecificationsApplicable revision:
PCI Express CEM Specification 1.0a x1, 2.5 GT/s signaling
This card can be installed in any of the PCI Express slots x1 to x16.
This card cannot be installed in a PCI slot. VoltagePower supply voltage: 3.3 V ± 9 % Current ConsumptionMax.
2.4 A WeightApprox. 0.15 kg (T-type connector excluded)  
PARTS NAME AND FUNCTIONS RCV lampLights when it detects signals on a control bus.
SND lampLights when it sends signals to a control bus. BNC connector Connects a T-type connector on a control bus.
F01E.ai U H VCRDNS DNS VCR BUS1 BUS2 VF702 SND lamp(BUS 1) RCV lamp(BUS 2) BNC connector (BUS 1)
BNC connector (BUS 2) RCV lamp(BUS 1) SND lamp(BUS 2) Figure Control Bus Interface Card (Front)  
External Dimensions
22 (w) 126.5 (H) 193.54 (D) mm
Regulartory Compliance
For conforming standards, see “System Overview�?(GS
33Q01B10-31E).
EMC Standards:
[CE Marking]
[C-Tick Marking]
 T-TYPE CONNECTOR AND
CONTROL BUS CABLE
CONNECTION
BUS1
BUS2
When
T-type
connector is
connected
Dust cap
(When T-type
connector
is not
connected)
Connect control bus cable
from previous station
Connect control bus cable to next station
(Connect a terminator when next station is not used)
 COMPATIBILITY WITH VF701
• The V net interface of VF702 is compatible with that of VF701, so that a mixture of VF701-installed stations and
VF702-installed stations is allowed on the same control bus.
• Setting the domain number and station number of a VF702 card can be performed in a same way as for a VF701
card.
• VF702 can be used in R3.05 or later.
 MODEL AND SUFFIX CODE
Model Description
VF702 Control Bus Interface Card
 ORDERING INFORMATION
Specify model.
 TRADEMARKS