Item |
Description |
Quoted P/N |
1 |
FLAME DETECTOR SCANNER |
261A1812P006/261A1812P010 is superceded by 261A1812P012 | 20140410
Ionization flame detector APR 056 028 - flame sensor 28FD - eliminates the leakage of gas without a flame.
The company Nuovo Pignone denotes its catalogs, as RRO56028.
GE stands firm in its catalogs, as 261A1812P003/261A1812P3 (261A1812P006/261A1812P6, 261A1812P008/261A1812P8, 261A1812P009/261A1812P9, 261A1812P010, 261A1812P012)
- Various numbers at the end of labeling - it's different kinds of wires.
There are also marking:
Honeywell LG1093AA01 - 10 inches of # 18 twisted pair - GE P/N 261A1812P003
Honeywell LG1093AA02 - 36 inch twisted pair # 18 - GE P/N 261A1812P006
Honeywell LG1093AA03 - 60 inches # 18 Twisted 3-wire hzhilny- GE P/N 261A1812P008
Honeywell LG1093AA05 - 500 inches - GE P/N 261A1812P009 Honeywell LG1093AA04 - 180 inches - GE P/N 261A1812P010
DETECTOR,FLAME,RRO56028
FLAME DETECTOR SCANNER
NUOVO PIGNONE
RRO56028
28FD
GE P/N: 261A1812P003, 261A1812P012
LG1093 Flame Sensor Characteristics
|
LG1093AA |
LG1093AB |
LG1093AC |
Mounting Interface |
3/4 inch internal NPT |
1.73 inch O.D. by 0.14inch wide flange |
1.73 inch O.D. by 0.14inch wide flange |
Control Panel Connection |
Teflon shielded cable with one inch external conduit thread. |
Two pin connector |
Two conductor armored cable. |
Operating Temperature |
-40°F to +350°F |
-40°F to +350°F |
-40°F to +350°F |
Window Pressure Rating |
150 psig at 400°F |
6.3psig |
6.3psig |
Special Certifications |
Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D CE Mark: EMC Directive 89/336/EEC ATEX Directive 94/9/EC II 2G EEx d IIA T3 or EEx d IIC T3 Models AA34/35/36/44/45/46 |
None |
CE Mark: EMC Directive 89/336/EEC ATEX Directive 94/9/EC Models AC01......09 |
Cable Lengths |
AA24/AA34: 16ft (4.9m) AA25/AA35: 42ft (12.8m) AA26/AA36: 61ft. (18.6m) |
|
AC01/AC02: 9ft. (2.7m) AC05: 24ft. (7.3m) AC09: 60ft (18.3m) |
EG1033 Amplifier Characteristics |
|
EG1033AA |
EG1033AB |
EG1033AC/AD |
Physical Dimensions |
6.62 x 4.25 x 2.32 inches |
6.62 x 4.25x4.44 inches |
6.62 x 4.25x4.44 inches |
Mounting Holes |
Four .20 in diameter holes, 6.00 x 2.00 inches apart |
Four .20 in diameter holes, 6.00 x 2.00 inches apart |
Four .20 in diameter holes, 6.00 x 2.00 inches apart |
Power Input |
28 + 0.14 Vdc, 0.5 amps max |
115 Vac +/- 10%, 60 Hz, 10 watts max. |
20 to 35 Vdc, 10 watts max |
Amplifier Output |
Transistor open collector |
Relay Contacts |
Relay Contacts |
Flame Detect Time |
Typical 0.1 sec; max 1.0 sec |
Typical 0.1 sec; max 1.0 sec |
Typical 0.1 sec; max 1.0 sec |
Flame Loss Detect Time |
0.2 sec max |
0.2 sec max |
0.2 sec max |
CE Mark: EMC Directive 89/336/EEC LVD Directive 73/23/EEC |
Yes |
No |
Yes |
Note: Each amplifier will power two sensors, single or dual applications, and provide a separate output signal for each sensor. The EG1033AD model allows separation of the chassis ground shield connection from the input power low, distinguishing it from the EG1033AC. |
|