Siemens unused SGT5-4000F gas turbine for sale
Project Name: | Siemens unused SGT5-4000F gas turbine for sale | Main Equipment Brand: | Siemens | Main Equipment Model: | SGT5-4000F | Origin of Product: | | Project Progress: | 新项�?New Project | Project Country: | | Project Capacity: | | Summary Briefs on the Project: | | Project Role: | | Bidding Or Negotiation: | | Project Funding: | | Payment Terms: | | Project Type: | | Project Start And End Time: | - | Name Of Project Partners: | | File Link: | NO_File |
Gas Turbine Package Gas Turbine | Quantity | Gas turbine type | SGT5-4000F | Number of offered gas turbines | 2 |
|
| Each gas turbine mainly comprising: |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> ring combustor | 1 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Turbine | 1 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Compressor | 1 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Bearings | 2 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Gas turbine instrumentation and actuation | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Gas turbine insulation | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Shaft turning gear | 1 |
The gas turbine will be subjected to tests, as defined in Supplier’s quality assurance specification. Kindly refer to section “Standard QA Programs�?for more details. Gas Turbine Auxiliaries | Quantity | Base Module, comprising the auxiliary packages for | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Fuel gas and ignition gas within separate compartment |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Lube oil with Plate Type heat exchanger 2x100 |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Hydraulic oil supply for valves and actuators |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Hydraulic clearance optimization |
|
Fuel and ignition gas components integrated into the interconnecting piping | 1 per gas turbine |
Gas Turbine Auxiliaries | Quantity |
Fuel Gas Package for Natural Gas | 1 per gas turbine | Hydraulic Supply System | 1 per gas turbine | Lube and Jacking Oil System | 1 per gas turbine |
Natural Gas Flow Metering for Performance Test (loose supply only) | 1 per plant |
Mobile Compressor Cleaning System, including hose connection to cleaning water nozzle system | 1 per plant |
Gas Turbine SystemsQuantityAir Intake System1 per gas turbine�?nbsp; Filter system with pre- and fine filter (multi-stage static filter) �?nbsp; Inlet air filter house including weather hood, bird screen, weather louvre, internal support structure, instrumentation, lighting, power sockets, access ladders, platforms and doors �?nbsp; Interconnecting duct work with expansion joint, manhole, damper and silencer �?nbsp; Electrical hoist for maintenance (250kg) �?nbsp; Dehumidifier for gas turbine standstill �?nbsp; Nozzle system for compressor cleaning inside air inlet plenum
|
| Exhaust Gas System1 per gas turbine�?nbsp; Exhaust gas diffuser �?nbsp; Compensator between Gas Turbine and Exhaust gas diffuser
|
|
Gas Turbine Control System | Quantity | Control System Type | SPPA-T3000 |
|
| Turbine Controller | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Redundant automation processor for closed-loop control functions |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> I/O modules, as per I/O |
|
|
| Turbine Failsafe Protection and Trip System | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Failsafe system for protection and trip functions |
|
|
| Turbine Function Group Automatic and Operational Protection System | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Redundant automation processor for open-loop control functions, sequence control functions and operational protection functions |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> I/O modules, as per I/O |
|
|
| I&C Cables | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Turbine related special instrument cables at turbine and on skids (from sensor to junction box) |
|
|
| Application Server | 1 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Redundant server for operating, monitoring, engineering function |
|
|
| Turbine Operating / Monitoring / Engineering System | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Operator terminal with 2x 24�?LCD monitor, keyboard and mouse |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Printer, DIN A4 color laser |
|
|
| Turbine Network Bus System | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> SPPA-T3000 bus system with necessary network components |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Fiber optic bus cable to plant central control room, maximum length | 300 m |
Signal Interface with Plant Distributed Control System | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Terminal points for hardwired signal exchange |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Maximum number of signals per turbine package | 30 | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Terminal point for bus signal exchange (with OPC) |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Maximum number of signals per turbine package | 500 |
WIN_TS Diagnostic System | 1 set | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> WIN_TS analysis system hardware + peripherals |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Software module for gas turbine special condition monitoring |
|
Gas Turbine Electrical Equipment | Quantity | Power Control Center (UBA01 / UBA02) | 2 per gas turbine |
|
| AC Power Supply System |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Low voltage switchgear, AC MCC (BFE / BME) | 2 per gas turbine |
|
| DC Power Supply System |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> DC voltage distribution (BUB / BUC) | 2 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Battery (BTA) | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Battery charger (BTL) | 2 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> DC/DC converter (BUK) | 2 per gas turbine |
Gas Detection and Fire Protection System | Quantity |
| Gas Detection System | 1 per gas turbine |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Gas detectors, horns and beacons, control unit |
|
| Covering following areas: |
|
| Gas turbine Enclosure |
|
| Fuel gas Skid / Valve Area |
|
| Fuel Oil Skid |
|
| Dual Fuel Module |
|
| Fire Detection System for Gas Turbine Unit1 per gas turbine�?nbsp; Fire detection and control system with local panel Covering following areas: Gas turbine enclosure and fuel gas Skid / Valve Area equipped with flame and heat detectors Base module equipped with smoke and heat detectors Power control center equipped with smoke detectors Dual Fuel Module equipped with smoke and heat detectors Fuel Oil Skid with smoke and heat detectors Lube Oil Skid equipped with smoke and heat detectors Hydraulic Skid equipped with smoke detectors Generator Bearings equipped with smoke detectors Fire Extinguishing System1 per gas turbine�?nbsp; CO2 storage system and direction valve station �?nbsp; Battery of high pressure bottles for CO2 and direction valve station �?nbsp; Piping system from bottle rack / storage system to spray nozzles inside the enclosure incl. supports Covering following areas: Gas Turbine Enclosure Fuel Gas Skid / Valve Area Enclosure Power Control Center Base Module Enclosure Dual Fuel Module Enclosure Fuel Oil Skid Enclosure Lube Oil Skid Enclosure Hydraulic Skid Enclosure �?nbsp; Full discharge test for Gas Turbine Enclosure1 per gas turbine
|
|
Noise Protection Measures | Quantity | Noise Enclosure for Gas Turbine | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Structural steel, with corrosion protection |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Noise abatement panels, galvanized |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Internal service platforms and ladders, galvanized |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Doors with safety windows |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Internal lighting, including emergency lighting |
|
|
| Ventilation System for Gas Turbine Enclosure | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Air intake openings with protective grills, dampers and silencer |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Air handling unit, equipped with back draft dampers, fans including mechanical redundancy, and silencers |
|
Weatherproof Noise Enclosures for Gas Turbine Auxiliaries | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Fuel gas valve section, ventilation combined with gas turbine enclosure |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Base module |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Dual fuel module |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Fuel oil skid, including forced ventilation |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> NOX water injection skid, including forced ventilation |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Lube oil skid |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Control oil skid |
|
Noise Protection Measures for Gas Turbine Systems | 1 per gas turbine | �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Sound barrier walls alongside the exhaust gas diffuser |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Sound barrier walls alongside the exhaust gas bypass stack |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Sound barrier walls around the exhaust gas stack |
| �?span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 9px; line-height: normal; font-family: "Times New Roman";"> Enclosure for exhaust gas diffuser, including forced ventilation |
|
|
Pubdate: 2022/7/24 12:48:11 |
|
Click add item to inquiry basket Click Copy Shared Links | Inquiry Basket |
Pageviews: 1
|
|