Name of New Equipment: | Introduce to auxiliary equipment of internal CMPC JCPC combustion engine power station | Brand name of Equipment: | CNPC Jichai | P/N of Equipment: | SCADA system | Industry: | Gas Power Generation Industry | Summary Briefs on the equipment: | | Origin of Product: | | Original Packing: | 带原厂商包装 Original Packing | Warranty: | | Installation, commissioning service: | | Role: | 设备所��方Owner of equipment | Already Sold or not: | | Time of first Sold: | | Already sold coutry or region: | | Rough budget or contract value: | 货币选择 | Payment Terms: | | File Link: | NO_File |
Introduce to auxiliary equipment of internal CMPC JCPC combustion engine power station Cooling tower characteristic�?/p>
Low cost,high cooling efficiency High water consumption Equipped with cooling water pump0 Low power consumption Horizontal radiator characteristic:
High cost,high cooling efficiency Low water consumption, but high requirement for water quality in inner circulation Large floor space, but easy to assembly in scene
High power consumption
Suitable for use in power stations with ample water supply and multiple units Suitable for areas where water resources are strained High voltage switchgear
High-voltage switchgear is widely used in high-voltage generator sets. The main functions of the switchgear are transmission,equipment and line protection, and can also be used as the generator generating point and power grid acccss point. Range�?630〜4000 A Working voltage�?3 〜13.8 KV,frequency�?50Hz / 60 Hz
Equipped with comprehensive protection devices, current transformers,lightning arresters and other electrical components
As a main switch of high-voltage generator set, add voltage transformer and generator comprehensive protection device and harmonic elimination devse.
Voltage transformer cabinet
Generally, it is directly installed on the busbar. Its internal main configured voltage transformersand harmonic elimination devse. The main function is to provide voltage measurement for high-voltage systems and to protect devices such as metering devices. DC panel Supply direct-current for high voltage operation system The 220v power supply can also provide other levels of DC voltage. Internally equipped with batteries and complete Rectification system.
Power transmission and distribution system�?br/>Power transmission and distribution systems mainly include power transmission, power distribution and electrical protection functions. CNPC Jichai can provide you with high and low voltage switchgear, measurement, protection and control equipment required by the power station. Advanced technology and excellent quality. Main equipment in low voltage system�?br/>Control panel for diesel or gas Generator set�?br/>Diesel and gas generator set control panel is designed for supporting generator sets�?br/> Power range�?10 ~ 5000 KW Detection parameters�?Voltage, current, power, frequency etc. Protection�?Acousto-optic alarm or shutdown protection when the protection setting is reached Advanced Import Automation Parallel and Grid Module Provide unit monitoring data remote transmission interface Low voltage switch gear cabinet; The low-voltage switchgear is mainly used for the entry/ exit of low-voltage busbars and distribution of power equipment, and is equipped with protection devices, which facilitates the entry and exit lines of the power station generator set busbars, the power distribution of the power station low-voltage self-use electrical systems, and the control and protection of power plant power equipment. Range�?�?4000 A Working voltage�?�?AC 660V , frequency�?50Hz / 60 Hz Standard module�?Flexible combination Motor centralized control�?Reactive power compensation According to user demand, cabinets such as MNS, GCS, GCK, GGD and 8PT can be provided. Step-up and step-down system main equipment�?br/>Transformer�?As the main electrical equipment of the power station, the transformer has step-up transformers and step-down transformers, which can be selected according to the needs of the power station. Range�?80 ~ 3150 KVA Differential protection available�?�?2000 KVA Oil-immersed and dry-type transformers can be selected and supplied on demand
The heat-electric-cooling triple-feedback system uses the waste heat generated by power generation for secondary use, and at the same time outputs a power, cold, and heat distributed energy supply system to the user. The overall energy utilization rate is over 80%. Waste heat recovery system�?/span> SCADA system introduce T h e S C A D A s y s t e m mainly completes the real-time data acquisition and process control (such as PLC control) of various parameters of the power station generator set and its auxiliary equipment (such as cooling system, fuel system, etc.), and can also be used in data exchange with other systems with standard interfaces and protocols. The monitoring system can control the operation status of the power station equipment and implement related functions such as protection, data browsing, fault alarm, power generation statistics, report printing, historical data query, and web access.
|