BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   Spare Parts   |   Project Financing    |   Equipments   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   Exclusive-Distributor   |   Exchange Link  

Mail List

E-mail:

Spare Parts
     GE-Gas-Turbine-Parts  
     Bently Nevada  
     Speedtronic  
     GE-Fanuc  
     GE Druck  
     GE-Multilin  
     GE Panametrics  
     Yokogawa  
     FLENDER & Flender Graffenstaden  
     QUALITROL  
     Schneider Electric  
       Telemecanique  
       Gutor Electronic  
       Invensys Foxboro  
     Siemens  
     Michell Instruments  
     Vickers  
     Metso  
       Neles  
       Jamesbury  
     Blade, Vane for NP, PGT-10, Frame 3, Frame 5  
     Honeywell  
       FEMA  
       MAXON  
     metrix vibration  
     Allen-Bradley  
     CCS  
     Deutz-MWM  
     Caterpillar  
     Esco Couplings  
     Woodward  
     NORGREN  
     Parker  
     Foxboro  
     Invensys  
     Asco  
     Swagelok  
     AMERICAN-AIR-FILTER(AAF)  
     HERION  
     Dynisco  
     Pepperl+Fuchs(P+F)  
     Fisher  
     Timken  
     ABB-Ontrac ELECTRIC ACTUATOR OF POWER PLANT  
     Philadelphia Gear(Western Gear, WesTech)  
     Coaxial Valves  
     DENARDO WIRE & CABLE  
     leslie Laurence Valve  
     Altra motion  
     ATLAS COPCO  
     Colfax Corporation  
       Allweiler  
       Houttuin  
       IMO  
       Tushaco  
       Warren Pumps  
       Zenith  
     ROTORK  
     Emerson  
       Appleton  
       Control Techniques  
     MOOG  
     DOLLINGER CORPORATION  
     Viking-Pump  
     Samson  
     KRAISSL  
     KRACHT  
     ECO Gearchem  
     Pratt & Whitney  
     OVAL  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > Spare Parts > GE Panametrics - DigitalFlow XGM868I GE Panametrics Gas Flow Ultrasonic Transmitter


Google

DigitalFlow XGM868I GE Panametrics Gas Flow Ultrasonic Transmitter

DigitalFlow™ XGM868i
GE Panametrics Gas Flow Ultrasonic Transmitter
 
 
Applications
The DigitalFlow XGM868i gas flow transmitter is a complete ultrasonic flow metering system for measurement of most gases including:
 
 Hydrocarbon gases
 Vent gases
 Biogases
 Digester gases
 Fuel gases
 Waste gases
 Incinerator air flow
 Vapor recovery
 Stack gases
 Other gases
 
The DigitalFlow XGM868i gas ultrasonic flow transmitter is designed to measure the flow rate of virtually any gas.
The DigitalFlow XGM868i flow transmitter offers a unique combination of rangeability, ease of installation, low maintenance and accuracy in a low-cost transmitter. The state-of-the-art XGM868i shares the many advantages offered by the other products in the GE line of innovative ultrasonic flowmeters. The all-digital XGM868i creates no pressure drop; has no moving parts or parts that
foul or collect debris; seldom requires maintenance; and provides reliable, drift-free operation.The flow rate can be displayed locally or transmitted to a remote system via an analog or digital communications link.
Transducer Type
T5 Wetted Transducer
T17 Wetted Transducer
 
Flow Measurement Range
Standard Range
-150 to 150 ft/s (-50 to 50 m/s) - bidirectional
 
Applicable Pipe Sizes
Diagonal 45
3 in to 14 in (50 to 350 mm) OD
14 in to 120 in (350 to 3000 mm) OD
 
Bias 90
Note 1 & 2
Not Applicable
 
 
Design Velocity Accuracy from 1 to 150 ft/s (0.3 to 50 m/s)
 
Transducer Type
T5 Wetted Transducer
T17 Wetted Transducer
 
Number of Paths
One Path
Two Paths
One Path
Two Paths
 
 
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
 
Pipe Dia. </= 6 in.(150mm)
+-2.5%
+-2.0%
+-2.0%
+-1.5%
NA
NA
NA
NA
 
Pipe Dia. >/= 6 in(150mm)
+-2.0%
+-2.0%
+-1.5%
+-1.5%
+-2.0%
+-2.0
+-1.5%
+-1.5%
 
 
Calibrated Velocity Accuracy from 1 to 150 ft/s (0.3 to 50 m/s) �?see notes below
 
Transducer Type
T5 Wetted Transducer
T17 Wetted Transducer
 
Number of Paths
One Path
Two Paths
One Path
Two Paths
 
 
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
1 ft/s (0.3 m/s)
>3 ft/s (1 m/s)
 
Pipe Dia. </= 6 in.(150mm)
 
+-1.5%
+-1.0%
+-1.0%
+-0.75%
NA
NA
NA
NA
 
Pipe Dia. >/= 6 in(150mm)
 
+-1.0%
+-1.0%
+-0.75%
+-0.75%
+-1.0%
+-1.0%
+-0.75%
+-0.75%
 
 
Flow Velocity Sensitivity from .1 to 1 ft/s (0.03 to .3 m/s)
 
Pipe Dia. = 10 in.(250mm)
±0.12 in/s(±0.004 m/s)
±0.08 in/s( ±0.003 m/s)
NA
NA
 
Pipe Dia. = 14 in.(250mm)
 
±0.12 in/s(±0.004 m/s)
±0.08 in/s( ±0.003 m/s)
±0.08 in/s(±0.003 m/s)
±0.06 in/s( ±0.002 m/s)
 
Pipe Dia. >/= 20in. (500mm)
 
±0.12 in/s(±0.004 m/s)
±0.08 in/s( ±0.003 m/s)
±0.06 in/s( ±0.002 m/s)
±0.04 in/s(±0.0015 m/s)
 
Note 1  Accuracy and sensitivity are dependent on pipe diameter, molecular weight and temperature. All accuracy specs assume molecular weights
greater than 24 kg/kmole and temperatures less than 100 °F (38 °C)
 
Note 2  Accuracy is dependent on straight run. All accuracy specs assume a fully developed flow profile or a minimum straight run of 20D upstream and 10D downstream
 
Note 3  Stated accuracy may be achieved with total straight run as little as 10D using flow profile correction - contact factory for details
 

- TRANSMITTER
- GENERAL PURPOSE GAS FLOW
- PRESSURE RANGE : STANDARD 0 PSIG TO 2700 PSIG
- ( 1 BAR TO 187 BAR )
- CONNECTION DATA : PROCESS CONNECTION FLANGED AND COMPRESSION FITTING
- <(>,<)>
- TRANSDUCER ( SENSOR ) NOT INCLUDED
- MANUFACTURE : GE SENSING PANAMETRIC
- MODEL/TYPE : PANAMETRIC DIGITAL FLOW XGM868I
- OPTION CODE :
- B - 1 SINGLE CHANNEL
- C -2 , 12-28 VDC
- D - 1
- E �?FT
- F �?1
- G �?4
- H �?1
- I ( COMMUNICATION
- J ( TRANSDUCER FREQUENCY )





Copyright©2006-2013 Leda Greenpower Beijing ICP Reg. No: 10010978
   Fax:0086-10-84161062  E-mail:
[email protected]
[email protected]   Google