BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  

Mail List

E-mail:

Equipments
     Gas turbine & spare parts  
       GE 9FA 255mw Gas Turbine Generator  
       GE Licensed MS9001E Series Gas Turbine plant  
       42MW GE Gas Turbine Generator  
       PG6581B Gas Turbine Series Generator Plants  
       PG6581B Gas Turbine Set Supply Scope  
       Gas Turbine Generator Site Inspection  
       Quotationon Used PG6551B gas turbine plant  
       2MW Gas Turbine Generator  
       7mw-Siemens-SGT200-Gas-Turbine-Cogeneration-unit  
       10MW Gas Turbine Generator  
       Used Gas Turbine Generator Plant  
       Technical-Specification-PG6581B-Gas-Turbine  
       Supply-Scope-of-PG6581B-Gas-Turbine  
       Budgetary Cost for 108MW Gas Turbine Plant  
       Gas Turbine Generator Compressor Unit Power Plant  
       Siemens Gas Turbine Generator  
       ABB-Siemens-ALSTOM-Gas-Turbine-Spare-Parts  
     HFO Diesel generator & Marine HFO Engine  
       8x8735kw MAN 18V32/40 HFO Diesel power Proposal  
       8x 4.1mw MAN 9L32/40 hfo power plant proposal  
       10x5.5MW MAN 12V32/40 HFO diesel plant proposal  
       3mw-9mw MAN 18V32/40 HFO Diesel generator  
       6 units 5.5mw MAN 12V32/40 hfo diesel plant  
       3x3.5mw MAN 8L 32/40 hfo diesel generator plant  
       1MW diesel generator   
       1.5MW Diesel Generator Set  
       2M Diesel Generator Plant  
       Sample Diesel Power Plant Proposal 9x2mw  
       Diesel power Plant List  
       Used Diesel Generator  
       Diesel Generator Pictures  
       Bio diesel generator power plant MW  
       Sample Pack List for 10x2MW HFO diesel power Plant  
       10kw-4000kw-Cummins-MTU-diesel-generator-set  
       HFO-diesel-generator-sets-running-on-biodiesel  
     MTU Cummins Perkins Volvo Diesel Generator  
       List of MTU Cummins PERKINS diesel generator  
       Leroysomer Siemens, Marathon Generator  
       MTU-Cummins-Perkins-diesel-generator-spare-parts  
       Germany-Deutz-diesel-generator-and-spare-parts  
     Spare Parts for Steam Turbine Power Plants  
     Power Plant Generator  
       Air Cooled Power Generator  
     Steam Turbine  
       Extraction Condensing Turbine  
       Condensing Steam Turbine  
       Recovery Turbine  
       Extraction Turbine  
       Required Data for Quotation  
       Alstom-Licensed-330MW-Steam-Turbine  
       Quotation-50MW-condensing-steam-turbine  
       Quotation-30MW-Condesing-Steam-Turbine  
     Boiler  
     Hydro Turbine  
     Engineering Machinery  
       Truck Mounted Crane Crawler  
       Trailer Concrete Pump  
       China track Bulldozer  
       China Crane  
       Benz Truck and Lorry from China  
       China-heavy-industry  
       China-outstanding-buses-and-coaches  
     Cable&Wire  
     New Building Cargo Ships vessel Finance from China  
     Dual Fuel Engine Generator  
     Electric Motor  
     China Famous Equipments for Power Plant  
     MTU Deutz MWM Diesel gas engine for marine land  
     Transformer in MVA  
       Germany Certificates  
       Required Data for Quotation  
       Transformer Reference  
       Sample Inquiry  
     Wind Turbine Generator  
     Oil-Well-Drill-Bit  
       Oil-Well-Drill-Bit-Main-Products  
       Drill-product-series  
       Other-oilfield-products  
       Kingdream Rock Bits Catalouge 2011  
       IADC-CLASSIFICATION-OF-KINGDREAM-BITS  
       ROCK-BIT-COMPARISON-CHART  
     Drilling-Rig-for-Oil-Gas-Mining  
       Main-products-Directory-introduction  
     Best-Diamond-Brand-Cemented-Carbide  
     China-famous-steel-producers   
     China Largest Steam Turbine Producer  
       Harbin-Electric-Group-Spare-Parts  
     China-Best-Largest-Steam-Turbine-producers  
     Ingersoll Rand Air Compressor  
     Leading-farm-machinery-and-engineering-mechanical  
     Sawblade  
     Pump and pump parts  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > Equipments > MTU Cummins Perkins Volvo Diesel Generator - The diesel generators knowledge introduction


Google

The diesel generators knowledge introduction

 

Diesel generator sets
       Captive power plant diesel generator sets are a type of AC-powered device is a small independent power generation equipment to combustion engines for power, driven synchronous generator and power generation.
Modern diesel generator set diesel engine, three-phase AC brushless synchronous generator, control box (screen), cooling water tank, coupling, fuel tank, muffler and other components of public base steel as a whole. The engine flywheel and the generator uses the front cover of the axial positioning of the direct connection convex form one shoulder, and the use of cylinder-type flexible coupling from the generator directly driven flywheel rotates its way connected together by a screw, so that the two are connected into a steel body, to ensure the engine's crankshaft and generator rotor concentricity within the specified range.
Diesel generators and synchronous generators by a combination of internal combustion engine, the engine maximum power by parts of mechanical load and thermal load limits, known as the rated power, AC synchronous generator rated power is the rated speed, long-term continuous operation, the output power rating, usually diesel engine rated power output of the alternator output and synchronization between the rated power, called matching ratio.
Diesel generators
1 Overview
Diesel generator set is a small power generation equipment, means the diesel fuel to diesel engines as prime mover driven generator to power machinery. General by the diesel engine diesel generator, generator, control box, fuel tank, starting with the storage battery and control, protection, emergency cabinet and other components. Can be fixed based on the overall positioning using, also mounted on a trailer for mobile use.
Diesel generator sets are non-continuous operation of power generation equipment, continuous operation if more than 12h, the output will be lower than the rated power of about 90%.
Although lower diesel generator power, but because of its small size, flexible, lightweight, fully furnished, easy to operate and maintain, it is widely used in mining, railways, field site, road maintenance, as well as factories, businesses, hospitals and other departments as a temporary backup power supply or power. In recent years, newly developed unmanned automatic emergency power plants, more kinds of generating units to expand the scope of use.
At present, China has a production capacity of export production plant in Tianjin more than 10 plants and other power equipment. Products are exported to Europe, Asia and dozens of countries and regions, well received.
2 Classification and specifications
Diesel generator sets to the size of the generator output power to classify units of energy from 10kW-750kW variety of specifications. Each specification is divided into a protective type (with super-speed, high temperature, low oil pressure protection device), emergency-type and several structure-based mobile station. Which mobile station is divided into speed and vehicle speed can match the high-speed and low-speed off-road type of ordinary mobile type.
3 Order Notes
Diesel generator set export inspection is based on contract or technical agreement on technical or economic indicators can be tested, the user in the selection and signing, should note the following:
(1) If the environmental conditions and calibration of diesel generator sets the value of a gap when the environmental conditions should be described in the contract when the temperature, humidity and altitude values, in order to provide appropriate models and equipment;
(2) Description taken in the cooling mode, in particular, large capacity units, should pay attention;
(3) When ordering, in addition to illustrate the unit model, but also shows selection of the model;
(4) diesel engine group voltage regulation rate of 1%, 2%, 2.5% of the rated voltage. Choose what should description;
(5) normal delivery, provide a certain amount of wear parts, while necessary, should be described.
4 test items and methods
Department of diesel generator sets of products, including diesel engines, generators, control components, protection devices. Exports of machine inspection, including the following:
(1) product technology, test data review;
(2) Product specifications, models, mainly structural dimensions;
(3) the overall appearance of the product quality;
(4) Unit Performance: The main indicators of technical parameters, plant operation flexibility, the reliability of automatic protection devices, sensitivity;
(5) the contract or technical agreement of the other projects.

 

Purchase based on diesel generator sets

First, the basis for purchase of diesel generator sets

1 diesel generator sets selected performance and quality must meet the standards

Diesel generators are widely used in telecommunications, finance departments, hospitals, schools, business and other departments, industrial and mining enterprises and residential standby power, military and field operations, shipping and other special purpose vehicles and a separate power supply.

Diesel generator sets as a communication, must meet the GB2820-1997 in the G3 or G4 grade level requirements at the same time and "communication with the diesel generator set network access quality certification testing implementation details" under the 24 performance requirements, but through China's trade authorities have set up communications power supply Quality Supervision and Inspection Center of rigorous testing.

As a military communications diesel generator sets, must meet the GB2820-1997, GJB standards and force departments to develop a "communication power supply quality testing standards" requirement, and to the organization department of the equipment through strict quality inspection.

2 diesel generators should be considered a major factor in choice

Unit selection factors should be considered mainly mechanical and electrical properties, the use of the unit, load capacity and range, automated functions.
(1) unit uses. As the diesel generator can be used commonly, three kinds of backup and emergency situations. Therefore, use of diesel generator sets of different requirements there is a distinction.
(2) load capacity. Selection should be based on different uses of load capacity and load range, determine the stand-alone diesel generation set of machine capacity and backup diesel generator capacity.
(3) units using environmental conditions (mainly refers to the altitude and climatic conditions)
(4) the choice of diesel generators
(5) the choice of generator and excitation mode
(6) diesel generator automation options

Second, the optional standard diesel generator sets

> specified requirements of 24 performance indicators: ">Communication with the diesel generator set network access quality certification testing implementation details>> specified requirements of 24 performance indicators:

1 Appearance requirements
(1) diesel generator set limits size, mounting dimensions and connection dimensions are in line with prescribed procedures approved by the factory product design
(2) The unit should be firmly welded, the weld should be uniform, no welded wear, undercut, slag and porosity and other defects, welding slag, welding flux should be cleaned; film should be uniform, no crack and fall off; coating should be smooth , seamless plated spots, corrosion and other phenomena; unit should not be loose fasteners.
(3) diesel generator electrical installation should meet the circuit, each unit should be easy to fall off the wire connections clearly marked.
(4) diesel generator should be a good grounding terminal.
(5) diesel generators and complete signage content

2. Insulation resistance and dielectric strength
(1) Insulation resistance: the independent circuit electrical circuit between the ground and the insulation resistance should be greater than 2M
(2) Dielectric strength: an independent unit of the electrical circuit between the ground and the circuit should be able to withstand the test voltage AC 1min, there should be no breakdown or flicker.

Circuit voltage test voltage
less than 100V 750V
More than equal 100V 1440V

3 phase sequence requirements. Diesel generator control panel terminals of the phase sequence from the front control panel should be from left to right or from top to bottom order.

4 diesel generators to maintain ready for operation requirements. Unit should have a heating device, to ensure that its emergency starts and fast loading of the oil temperature, coolant temperature not lower than 15
ℿ/STRONG>

5. Automatically starts and automatic shutdown of power supply reliability check
(1) then self-control or remote start command, diesel power generation should be able to start automatically.
(2) The unit automatically starts after the 3rd failure, failed to start signal to be sent; equipped with reserve units, the program should be able to start the system automatically starts the backup command is passed to another unit.
(3) from the automatic start command is issued to the load time should be no more than 3min
(4) diesel generator starts automatically after the success of the first load, shall not be less than 50% of the calibration load.
(5) then self-control or remote shutdown command, the unit should be able to automatically shut down; and electricity for the grid and use the backup unit, when the grid is back to normal, diesel generators should be able to automatically switch or automatic shutdown, the shutdown delay shutdown mode time should be consistent with product technical requirements.

6, self-starting success rate. Automatically start the success rate of not less than 99%.

7, no-load voltage tuning range requirements. Unit load voltage setting range is not less than 95% -105% calibration voltage.

8, automatic replenishment functional requirements. Unit should be able to automatically start charging the battery.

9, automatic protection requirements. Unit should phase, short circuit (less than 250KW), over current (less than 250KW), too fast, high-temperature cylinder temperature, oil pressure protection.

10, line voltage sine wave distortion. In the no-load voltage calibration, calibration frequency, the sinusoidal line voltage waveform distortion rate <5%.

11 Steady state voltage regulation
Less  equal 250KW> 250KW
3% 2%

12, transient voltage regulation
Less  equal 250KW> 250KW
20% 15%

13, the voltage settling time
Less  equal 250KW> 250KW
Less  equal 2s Less  equal 1.5s

14, voltage fluctuation rate
Less  equal 250kw> 250kw
0.8% 0.5%

15, steady-state frequency regulation
Less  equal 250kw> 250kw
3% 3%

16, the frequency of transient regulation
Less  equal 250kw> 250kw
9% 9%

17, the frequency settling time
Less  equal 250kw> 250kw
5s Less  equal 5s

18, the frequency volatility
Less  equal 250kw> 250kw
Less  equal 0.8% Less  equal 0.5%

19, three-phase unbalanced load voltage deviation
Diesel generator set at 25% of the three-phase symmetrical load, in any phase calibration phase power plus 25% of resistive load, the unit should be able to work, the maximum or minimum line voltage and three-wire voltage average of 5%.

20, noise
Diesel engine and generator unit away from the noise sound pressure at 1m average:
Less  equal 250KW> 250KW
Less  equal 102db (A) Less  equal 108db (A)
Noise standards:
Sleep <45db ambient noise in residential areas during the day can not exc, , eed 50 dB at night should be less than 45 (40) dB
Work <65 db average person in the 40 decibel sound can be maintained under the normal reaction and attention, but at 50 decibels or more of the environment, will be a long time, hearing loss, emotional irritability, and even debilitating neurological and so on.
Listening to music more than 80 decibels noise 80db children live in an environment, resulting in up to 50% deaf person, noise level below 80 decibels only to maintain the long-term work will not be deaf for 40 years; at 100 dB, only 60% of people not deaf. If people are living in an environment where more than 80 decibels, can cause emotional irritability, hearing loss. Noise on the role of the human central nervous system damage, and can induce cardiovascular diseases, in strong noise environment, eating, gastrointestinal contraction of the capillaries occurs, digestive secretion and gastrointestinal motility will be reduced, so that normal blood supply has been damaged. Noise will result in a strong abnormal pregnancy, child mental retardation. Therefore, to minimize the daily life of noise sources and propagation.
85 db the following can cause a slight hearing loss;
85 db -90 decibels can cause noise-induced hearing loss a few people;
90-100 decibels can cause a certain amount of noise-induced hearing loss;
100 db or more, will result in a considerable number of noise-induced hearing loss, these are chronic noise-induced hearing loss.
105 db above --- 5 minutes schizophrenia

21, the fuel consumption rate. Rated power of 120 unit

22, diesel generator consumption. Unit rated power> 40KW, the unit consumption rate Less  equal 3.0G/KW.H

23, run the calibration test conditions
Unit at the required operating conditions (GB2820 in Section 4.2), the unit can be calibrated to the normal conditions of continuous operation 12h (including 10% overload operation 1h), and diesel generator sets should be no leakage and leakage phenomenon.

24, remote control, remote and telemetry performance
(1) intelligence unit
200KW or more units shall be intelligent, their monitoring of the content and interface requirements are as follows:
1 remote control: on / off, emergency stop, switch the main and backup units.
2 Remote letter: work status (run / stop), work (automatic / manual), the main use of the unit, overvoltage, undervoltage, overcurrent, frequency
3 Telemetry: Three-phase output voltage, three-phase output dynamic battery voltage, output power.
4 interface: should have a communication interface (RS-232 and RS-485/422) and can provide a complete communication protocol.

(2) non-intelligence unit
200KW and below, non-intelligence unit without remote control, remote and telemetry requirements.

Third, the choice of the emergency diesel generators

Emergency diesel generator is mainly used for an important place, in case of emergency or accident immediately after the power outage, emergency generators by the rapid power recovery and extend the period of time. Such as a load of electricity load. There are strict requirements on power-off time of equipment, instruments and computer systems, except with the generator should be located outside the battery or UPS.

The work of the emergency diesel generators have two characteristics:
No. 1 feature is for emergency use, continuous working time is not long, continuous operation is generally only a few hours (Less  equal 12H);
Section 2 is characterized as a backup, emergency generators usually in a wait state shutdown, only when the main power off all the drum barrier, the emergency diesel generators start to run until the supply of emergency power load, when the main power is restored to normal, then switch downtime.

(1) emergency diesel generator to determine the generating capacity

Emergency diesel generator set calibration capacity after 12h by the atmospheric correction calibration capacity, its capacity should be able to meet the total emergency power load calculations, according to the load generating capacity to meet a maximum capacity in a single motor starting requirements for verification . Emergency generator is generally used in three-phase AC synchronous generator, the calibration of the output voltage of 400V

(2) emergency diesel generator sets to determine the number

Multiple backup generators, generally only set up a Taiwan emergency diesel generator sets, from reliability to consider 2 units can also be used in parallel for power. Supply urgently generating units Number of units is generally not more than three. Elected with more than one unit, the unit should be selected models, the same capacity, voltage regulator, speed characteristics similar to the equipment, the nature of fuel used should be the same for maintenance and spare parts sharing. When the supply of urgently generating group 2, the self-starter 2 units should be able to spare each other, that mains power failure, power outage after delay after verifying the issue from the start command, if the first unit for three consecutive times from Failure to start, should send a warning signal and automatically start the first two sets of diesel generators.

(3) the choice of the emergency diesel generator

Emergency units should use high-speed, pressure, low fuel consumption, with the capacity of diesel generator sets. Single large-capacity high-speed turbocharged diesel engine, small footprint; diesel use with electronic or hydraulic control devices, speed performance is better; generator should be used with brushless excitation or phase compound excitation device synchronous motor, a more reliable, fault low maintenance and overhaul is more convenient; when a load capacity in a single air-conditioner or motor capacity is larger, better to use third-harmonic excitation of the generator; machine assembled in a shared chassis with a shock absorber; smoke outlet should be installed muffler to reduce noise on the surrounding environment.

(4) emergency diesel generator set control

Emergency generator set control should be fast from the start and automatic input device. When the main power supply after power failure, emergency unit should be able to recover quickly from the start and power supply, a load to allow time off from ten seconds to tens of seconds, according to specific circumstances. When important projects off the main power supply, the first 3-5S should be over a definite time, to avoid the instantaneous voltage drop and the city grid or BZT closing time, and then issued instructions start the emergency generator set . From the command issued, the crew began to start or speed to be able to take some time with full load. Generally large and medium-sized diesel engines need to process the pre-lubrication and warm-up to ensure that emergency load of oil engine oil pressure, oil temperature, cooling water temperature in line with the conditions of the plant product technology; pre-lubrication and warm-up process can be carried out according to different situations in advance . Such as military communications, the important foreign affairs activities of large hotels, public buildings, large-scale mass activities at night, the hospital for major surgery and other emergency units should be in normal times the pre-lubrication and warm-up state, in order to keep fast start, try to shorten the time power failure .

Emergency unit inputs, in order to reduce the sudden mechanical load and current impact, to meet the power requirements of the case, preferably by the time interval of emergency load rating increase. According to national standards and national military standard, automated self-starting after the success of the unit allows the loading of the first volume are as follows: rated power less than 250KW for those who, for the first time allow the load capacity of not less than 50% of the calibration load; for the calibration of power greater than 250KW who, according to the provisions of plant materials and technical conditions. If the instantaneous voltage drop and the transition process is not strict, generally sudden, or sudden unit unloading of the load should not exceed 70% of the capacity of the unit calibration.

Fourth, the common choice of diesel generator sets

Some of the diesel generator at a certain time or continuously for a long time often need to load commonly used as a power supply, such as generators used generators. Commonly used as a generator unit and the standby unit. Away from the large grid of townships, islands, forest, mining, oil and other regions or industrial and mining enterprises, in order to supply local residents and students living power plant, you need to install diesel generators, these generators usually be uninterrupted.

Defense engineering, communications hub, radio, microwave relay stations and other important facilities should be equipped with backup diesel generators. Such facilities usually available by the electric power grid supply. However, due to earthquakes, typhoons, wars and other natural disasters or man-made factors, the city suffered damage and power outages after the grid has set the standby unit should start promptly, and adhere to long-term continuous manner, to ensure that these important projects for electricity load continuous power supply, standby generators are also part of this common type of generator sets. Used generator sets continue to work long hours, the load curve greater capacity of the units, the number of units, type of choice and control units and emergency units in different ways.

1 used to determine the capacity of diesel generator sets

Long-term continuous operation by the unit output to meet the maximum calculated load the whole project selection, and the load should be based on the importance of backup generators to determine the capacity of the units. Diesel ongoing power output, usually 0.9 times the rated power.

2 sets of diesel generators used to determine the number

Number of units used diesel generator set is usually two or more, in order to ensure continuity of supply and meet the electricity load curve changes. Number of units and more units can only be determined according to the changes in power load of the units into the number of generators, the diesel engine is often in the economic load operation, to reduce fuel consumption, reduce electricity costs. The best economic engine running in rated power between 75% -90%. To ensure continuity of supply, the unit itself should consider setting common standby unit when the unit failure or downtime maintenance inspection, the generator is still important to meet the electricity load for continuous uninterrupted power supply.

3 used to determine the speed diesel generator sets

In order to reduce wear and increase the life of the unit, used generators should use no more than nominal speed of 1000r/min, the low-speed unit, the standby unit can select, high-speed unit. Should use the same power plant units with the model, with the capacity of the unit to use the same spare parts, easy maintenance and management. Load changes of the project, you can also use the same series in different capacity units. Calibration generator output voltage to determine the same with emergency generators, usually 400V, individual power capacity, transmission distance of the project can be used high-pressure turbine.

4 used diesel generator set control

Common units should generally be considered to be parallel in order to simplify the main power distribution wiring, and the unit start, stop rotation of running through and vehicles, transfer of load, switching power supply unit without interruption. Unit should be installed with the unit of measurement and control devices, speed control unit and the excitation-conditioning should be applied in parallel to the requirements of the fish. Significant load on the power of the standby generator set, diesel generator sets should use automated external power supply when the power failure, it can quickly auto-start and restore power to critical loads. Noisy engine room operation, the automated unit compartment to facilitate the transformation of operation, automatic control of generators. When the generator normal, the operator does not have to enter the engine room, in the control room can monitor for diesel generator sets.

Fifth, the order requires diesel generator sets

Make these selections in the diesel generator set shall be marked with the following general order:
(1) unit of the model, rated power, rated frequency, rated voltage, rated current, number of phases, power factor and connection methods.
(2) on the unit automation and performance requirements.
(3) of the diesel engine, generator and control panel of the structure, performance, installation size requirements.
(4) requirements for parallel operation of the unit: To purchase multiple units in parallel asking for, such as the need for parallel, but also suggest the need to provide the necessary measuring instruments and parallel devices.
(5) of the unit ancillary equipment requirements: many domestic manufacturers to cooling water tank (radiator), fuel tank, exhaust muffler, batteries, etc. to be regarded as ancillary equipment, installation of the proposed order would permit certain requirements.

Diesel engine Development history

Diesel generator Introduction and application

For more on diesel generator sets as MTU, Cummins, perkins, doosan or MAN HFO diesel generator , please click.

Genuine MTU, Cummins. Perkins, Volvo, Deutz,Caterpillar, Doosan  diesel generator spare parts 

As China-power-contractor.cn strategy, we are supplying you the TOP Producers equipment with most attractive price to the world thanks to our reputation and experience. Now we are choosing MTU Cummins, Perkins, Doosan, Volvo Diesel Generator sets and Their Spare Parts with shortest delivery Time and lowest Price from our one of consortium members. If you have enquiries for diesel generator sets of power projects by these DG sets, please send to: [email protected] [email protected] [email protected]

 




Statement: Any reference to the OEM, part number or other OEM, information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.