Coal Mine Methane (CMM) Fueled gensets
CMM USE IN IC ENGINES AT COAL MINES Coal mine degasification was originally developed to improve worker safety in coal mines, since explosive gas can form when methane mixes with air. Now, that gas can power the coal mine or be fed into the public power grid. The thermal energy can be used for heating purposes on-site, or be fed into a district heating system. And finally, mining companies can obtain additional revenues by selling Carbon Emission Reduction (CER) credits following the Clean Development Mechanism (CDM) or comparable mechanisms introduced among countries that have sighed the Kyoto Protocol. The main technical challenge in using coal mine gas in gas engines is the fluctuation of methane concentration during operation, as well as variations in gas pressure, humidity and quality that can be observed from one mine to the other. SD’s people took on this challenge 10 years ago and today is a leading supplier for such technology worldwide. Use the coal mine, coal bed gas or mine gas, through the gas explosion-prevention ventilator, explosion-prevention mist transportation system, gas and liquid separator, coarse colander, extract colander and electromagnetism valve, to mix the gas with the air in the gas engine and then conflagrate the mixed gas, in order to drag the generator to generate electricity. Electric power 625Kva/500kw 500GF1-2RW Methane content greater than 25% 500GF1-3RW Methane content greater than 25%

500GF1-3RW Coal Mine Methane Fueled gensets |

500GF1-2RW Coal Mine Methane Fueled gensets |
MINE METHANE GENSETS SPECIFICATIONS |
Description/ Genset Type |
500GF1-2RW |
500GF1-3RW |
Methane (CH4) |
25% |
9%-25% |
Electrical Output (kw) |
500 |
500 |
Voltage (V) |
400 |
400 |
Engine Type |
W12V190ZLDK-2B |
W12V190ZLDK-2C |
Aspiration |
Turbocharged Inter cooled |
Turbocharged Inter cooled |
Arrangement of cylinder |
V-12, 4-Stroke-Cycle |
V-12, 4-Stroke-Cycle |
Bore/Stroke (mm) |
190/210 |
190/210 |
Engine Speed (rpm) |
1000 |
1000 |
Fuel consumption (MJ/kWh) |
9.80 |
10.50 |
Exhaust temp. (oC) |
550 |
550 |
Ignition mode |
Spark-Ignited |
Spark-Ignited |
Starting Mode |
24V DC Power |
24V DC Power |
Total Displacement (Lit) |
71.45 |
71.45 |
Insulation |
Class F |
Class F |
Excitement |
Brushless excited |
Brushless excited |
Length (mm) |
5678 |
5678 |
Width (mm) |
1970 |
1970 |
Height (mm) |
2822 |
2839 |
Weight Empty (kg) |
12500 |
12500 |
CMM should be purified before burning in engine CMM temperature less than or equal 40oC
CMM pressure 3-10kPa; Fluctuation rate of pressure less than or equal 1kPa/min CH4 greater than or equal 9%; Fluctuate rate of CH4 less than or equal 2%/min Granule less than or equal 5um Granule less than or equal 30mg/Nm3 Moisture less than or equal 40g/Nm3
&, nbsp; For safety purpose, the O2greater than or equal 16% and total volume of CH4+O2 greater than or equal 28% if CH4 less than or equal 30%
China the most famous gas engine generator sets
For China gas engine generator sets or power plants, please click.
|