Technical data sheet |
Pos.1 | C.ref.: |
Code: | SAEX14.6-F14-B4-125-Ex de IIC T4-3ph/400V/50Hz-S2-15min-KS-A0001-6-8-11.-22.05-RH-10.1-99-EN-AL-03[K]-F (IEC 85)-L∙40∙40-IP68-AMEXC01.1-Ex de IIC T4-3ph/400V/50Hz-L∙40∙40-IP68-KS-A0001-KT∙105 (Ex e)-A2-49.2000P-41. 00-46.00-42.02-44.03-54.128-51.00-52.00 |
Wiring diagram: | MSPE310KC3--F00EJ TPA00R2AA-001-000 |
Valve attachment: | F14 || B4 || 500 Nm || 125 min⁻¹ |
Settings: | 500 Nm [ 500 Nm ] || 0 U/Hub [ 0 turns/stroke ] |
Comment: | Output drive B4-40, bore 40mm, DIN6885-1 Limit set to 312 t/stroke at output drive actuator |
Actuator design description: |
SAEX14.6 | Ex proof multi-turn actuator S2-15min short-time duty, classes A and B acc. to EN 15714-2 |
B4 | output drive: bore with 1 keyway (special bore) ø dy �?45mm ( 0-45 ) |
Ex de IIC T4 | explosion protection: acc. to ATEX II2G, IEC, CIS directive, Zone 1 (gas) |
3ph/400V/50Hz | mains voltage: three-phase AC 400 V 50 Hz |
KS | corrosion protection: KS is suitable for units occasionally or permanently exposed to aggressive chemical substances, average total film thickness 140 μm |
A0001 | colour: finish painting with standard colour for corrosion protection KN/KS/KX (AUMA silver-grey similar RAL7037) |
RH | closing direction: clockwise |
6 | torque switching: single switch (1NC and 1 NO) for each direction, switch contacts not galvanically isolated |
8 | limit switching: single switches (1NC and 1 NO) for each end position, switch contacts not galvanically isolated |
10.1 | reduction gearing with fixed reduction |
11. | position indication: mechanical position indicator |
22.05 | heater: in switch compartment 24 V (internal supplied) |
99 | accessory: valve identification number plate (KKS No.) |
EN-AL | Name plate: English, aluminium |
03[K] | motor protection: PTC thermistors 140 °C (according Din 44082) |
F (IEC 85) | motor winding insulation: insulation class F, tropicalized (IEC 85) |
L∙40∙40 | temperature design: suitable for ambient temperature -40 °C to +40 °C |
IP68 | enclosure protection IP68, submersible for max. 96 hours, max. 8 m head of water, up to 10 operations during the flooding |
AMEXC01.1 | Ex proof actuator controls AUMA MATIC |
Ex de IIC T4 | explosion protection: acc. to ATEX II2G, IEC, CIS directive, Zone 1 (gas) |
3ph/400V/50Hz | mains voltage: three-phase AC 400 V 50 Hz |
L∙40∙40 | temperature design: suitable for ambient temperature -40 °C to +40 °C |
IP68 | enclosure protection IP68, submersible for max. 96 hours, max. 8 m head of water, up to 10 operations during the flooding |
KS | corrosion protection: KS is suitable for units occasionally or permanently exposed to aggressive chemical substances, average total film thickness 140 μm |
A0001 | colour: finish painting with standard colour for corrosion protection KN/KS/KX (AUMA silver-grey similar RAL7037) |
KT105 (Ex e) | ex-plug/socket connector KT (Ex e), cable entries with M-threads 1 x M20 x 1,5 / 1 x M25 x 1.5 / 1 x M32 x 1.5 |
A2 | switchgear: reversing contactors (mechanically and electrically interlocked), power class A2 |
49.2000P | power supply unit: transformer, customer output 24 V DC |
41.00 | control: I/O Interface |
46.00 | control voltage: 24 V DC, internal or external supply |
42.02 | input signals: OPEN-STOP-CLOSE |
44.03 | output signals: OPEN-CLOSE-LOCAL-REMOTE |
54.128 | Motor protection: PTC tripping device, external reset and test |
51.00 | Selector switch: OHNE switches |
52.00 | Control elements: without switch |
Electrical data: | Motortype: ADX0090-2-3,30 || Speed: 2800 rpm || Power: 3,3 kW || In: 9,5 A || Imax: 21 A || Is: 68 A || cos phi: 0,65 |
Weight / Unit: | 68 kg |