General Information Company name: Location: Italy Year built: 1994 Startup date: Feb. 1995 Plant area: 19,000 m2 of which 1,300 m2 are covered
Production Technical Data
Cycle Type: Combined cycle with Gas turbine (GT) and GT Power Generator, Steam Turbine (ST) and ST Power Generator and Heat Recovery Steam Generator (HRSG) Emergency Cycle: Auxiliary Boiler to ensure continuity of customers supply steam Fuel: Natural Gas (Pressure 1,95 MPa) GT Produced Power: 38,34 MW NOx removal system: Steam Injection HRSG Produced Power: 62,5 t/h Steam (6,5MPa) 11,5t/h Steam (0,6MPa) ST Produced Power: 10 MW GT and ST Power Generators produced : 46 MVA GT-23 MVA ST Transformer: three windings with variable load of 75 MVA, 11 - 11/220K
Auxiliary Equipment Technical Data
Water supply: Well for industrial use and municipal water for sanitary purposes. ST condensation plant: air condenser Auxiliary Services: Cooling towers for GT �?ST and process equipment. Compressed air used for industrial services �?instruments and fire protection systems Demineralization plant: Reverse osmosis consisting of a traditional system with resins, ion exchange. Auxiliary Trasformers: Auxiliary Trasformers: AV 2 x 4.5 MVA 11-6 kV LV 2 x 1.6MVA 6 - 0,4 kV; Emergency 1 x MVA 22 - 0,4 kV Electrical Substation: Overhaud Substation 220 kV Gas Natural Substation: arrival by natural gas pipeline to a pressure of 1,2 MPa
Gas Turbine Technical Data
Name |
TG1 |
Manufacturer |
G.E. |
Gas turbine type |
MS 6541 B |
Serial Number |
5712 |
TG Power - ISO conditions |
Preselected load [MWe] |
- |
Base load [MWe] |
39 |
1st synchronizing |
Aug 1994 |
Operating Hours fuel gas |
Fire Hours: |
110.538 at 01/05/2010 |
Equivalent Operating Hours: |
not used |
Number of total starts |
- |
Anti-icing |
steam |
Filters |
Coalescer+prefilters+high eff. |
yes |
Self cleaning (pulse jet) |
no |
Aspiration system conditioner |
no |
Gas compressor |
yes |
Gas heating |
no |
NOx reduction system |
steam injection |
TG start device |
electric motor + torque converter |
O2 [%] |
15 |
NOx limit value [mg/Nm3] |
150 |
CO limit value [mg/Nm3] |
50 |
Particulate Matter limit value [mg/Nm3] |
- |
Steam Turbine Technical Data
Name |
TV |
Manufacturer |
ANSALDO |
Serial Number |
CDI 635R |
Power [MWe] |
15 (full condensing); 11 (cogenerative condition) |
1st synchronizing |
Aug 1994 |
Operating Hours |
108.906 at 01/05/2010 |
Condenser fluid |
air |
HEAT RECOVERY STEAM GENERATOR(HRSG) Technical Data
Number of unit |
1 |
Name |
GVR |
Manufacturer |
ANSALDO |
Post firing |
no |
Fresh air |
no |
Pressure level and Temperature |
HP [bar ; °C] |
70 ; 500 |
IP [bar ; °C] |
- |
LP [bar ; °C] |
6 ; 285 |
RH |
no |
HP Feedwater Pump |
Manufacturer |
KSB |
Q; H; T [m3/h ; m ; °C] |
69,7 ; ΔP max 75,5 ; 164 °C |
Auxiliary Boiler Technical Data
Number of unit |
1 |
Manufacturer |
CCT OLD (Macchi dallo 01/08/07) |
Capacity [t/h] |
52 lorde (52 nette) |
Pressure [bar] |
24 |
O2 |
[%] |
15 |
NOx limit value |
[mg/Nm3] |
150 |
CO limit value |
[mg/Nm3] |
100 |
Particulate Matter limit value
[mg/Nm3] |
- |
Power Generators Technical Data
TG Generator |
GEC ALSTOM |
Power of TG Generator [kVA] |
46.000 |
Cooling system of TG Generator |
air / water |
Operating hours |
110.538 at 01/05/2010 |
TV Generator |
ANSALDO |
Power of TV Generator [kVA] |
23.000 |
Cooling system of TV Generator |
air / water |
Operating hours |
108.906 at 01/05/2010 |
STEP UP TRANSFORMER Technical Data
Main Transformer |
TG |
ABB |
TV |
Type of transformer |
TG |
75.000 kVA ONAN (ONAF mod. EDISON) |
TV |
Gas Compressors Technical Data
Number of unit |
2 |
Manufacturer |
Nuovo Pignone |
Capacity [m3h] |
14.830 |
Pressure [bar] |
19.5 |
Air Condenser Technical Data
Type |
air condenser |
Manufacturer |
FBM |
Thermal Power [MWt] |
44 |
Cooling Towers Technical Data
Type |
evaporative tower |
Manufacturer |
MITA |
Thermal Power [MWt] |
unspecified |
WILL
|