FOR SALE ALSTOM 150Mw GAS TURBINE 500Mw STEAM TURBINE + GENERATOR
Gas Turbine: |
Manufacturer: |
Alstom/ABB, Model GT13E |
Capacity: |
150,000 kW (150MWE/18,5 MVA, cos phi 0,8) |
Frequency: |
50 Hz |
Year: |
1988 |
Speed: |
3000 RPM |
Fuel: |
Gas |
Last C-inspection: |
2004 |
Hours: |
OH 66.200 EOH 95.644 Starts 1.456 Trips 296 |
Emission: |
NOx 75 mg/Nm3 |
Efficiency: |
34.56% |
Additional equipment Kawasaki Ammonia De-Oxidation
Method, DLN Combustor Technology, EV Type Burners. Misc.
spare parts.
Note: New EV burner unit has been installed in 1996 |
Turbo generator |
Manufacturer: |
ABB |
Model: |
WTAL 534 |
Serial nr.: |
GM 204791 |
Capacity: |
187.500 KVA |
Speed: |
3000 RPM |
Volt: |
15.000 V |
Frequency: |
50 Hz |
Steam turbine: |
Manufacturer: |
Alstom/ABB |
Licensee: |
RDM |
Manufacture year: |
1978 |
Hours: |
146.935 OH; Starts 1.125; Trips 99 |
Type: |
Axial Excess Pressure |
Execution: |
Condensation Turbine |
Construction Type: |
Multi-Part |
Output, net: |
approx. 511 MW |
Output, gross: |
approx. 527 MW |
Speed (nominal): |
3300 RPM (10%) |
Speed: |
3300 RPM (10%) / 3360 RPM (12%) |
Number of taps: |
7 |
Make: |
BBC (HP-MP-LP) |
Type: |
D4 Y 456 A |
Extractions: |
0,23 / 0,72 / 1,51 / 4,9 / 11 / 22,5 bara at 62,9 / 90,2 / 130,2 / 242 / 437 °C. |
Efficiency: |
99,8% |
Generator: |
500MWE/625MVA/cos phi 0,8 |
Voltage: |
21 KV |
Maintenance: |
last retrofits: LP2005, MP2004, HP2002 |
Condenser: |
water cooled with vacuum 96,4 % |
Transformers: |
GT trafo: |
21KV -> 163KV |
EB trafo: |
10KV/ 3KV/ 400V en 35 MVA |
Operating hours: |
148.886 for boiler & steam turbine |
Fuel consumption: |
 /DIV> |
- GT 46.000Nm3/hr, |
 /DIV> |
- Boiler solo 86.000Nm3/hr /109 mt |
HFO (at 40,74 MJ/kg) Combi 132.000 Nm3/hr, |
|
|
- HFO specification: |
 /DIV> |
HFO sec.6500 RI/37 grdC / max S 2%. |
Boiler at 100% load: |
Make/type: |
Schelde / C-E steam boiler with forced circulation, single reheat, and overpressure furnace. |
Live steam: |
188 bar / 540 °C |
Capacity: |
1610 mt/hr |
Fuel: |
Gas / HFO |
Burnertype: |
Dual fuel: Tangential arrangement |
Emission: |
NOx 90 mg/Nm3 |
Efficiency: |
Solo steam turbine operation 40%. In combination with gas turbine 43% |
Eco inlet: |
263 °C |
|  |
|
|
|