BBS  Email&MSN: [email protected]
  
Homepage   |   Power Generation   |   Project Financing    |   Equipments   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Spare Parts   |   BBS-Blog   |   Exclusive-Distributor   |   Exchange Link  

Mail List

E-mail:

Home > Used Equipment - 600 MW SUPERCRITICAL GE COAL FIRED STEAM TURBINE GENERATING STATION POWER BLOCK EQUIPMENT FOR SALE


 

600 MW SUPERCRITICAL GE COAL FIRED STEAM TURBINE GENERATING STATION POWER BLOCK EQUIPMENT FOR SALE

We have available NEW This Unit 1 power block is a coal-fired electric generating unit comprising a nominal 600 MW GE steam turbine, tandem-compound 4-flow single reheat unit with throttle conditions of 3500 psig, 1050°F/1100°F.  The Alstom steam generator is rated at approximately 4,650,000 lbs per hour capable of burning bituminous coal only or a combination of bituminous coal and petcoke (up to a 70%/30% blend). Coal pulverizers have significant design margin operating at ~70% for MCR firing.
 
The plant design heat rate with this power block is 8725 BTU/kw-hr with turbine control valves wide open (VWO) and average ambient conditions in southeastern U.S. with a circular mechanical forced draft cooling tower, an electrostatic precipitator, and a wet limestone flue gas desulphurization system. All cycle design has been incorporated into the equipment for sale and cycle information is available for all other normally desired conditions.
Included with the block procurement of the equipment listed for sale is the design documentation of the power block. This includes all drawings, specifications, calculations, 3D modeling etc. at the stage that currently exists. For sale separately are the continued services of the engineer of record for this design. As summary of the status of design is as follows.
 
The asking price for everything is $267,800,000.00 USD.  If you are interested please let us know so we can provide more details.  We  already have an NDA and Commission agreement in place with the owner.
 
600 MW SUPERCRITICAL GENERATING STATION POWER BLOCK  Equipment for Sale
DESCRIPTION
VENDOR NAME OR OTHER INFORMATION
SCOPE OF SUPPLY
TURBINE GENERATOR AND ACCESSORIES
GENERAL ELECTRIC
Steam Turbine and Generator
Two Boiler Feed Pump Turbines
Turbine Lube and Hydraulic Oil System
Steam Turbine and BFPT Mark VI control system
Bently Nevada vibration monitoring system
Generator Stator Cooling Water Skid
Generator Protection Panel
Generator Neutral Grounding Equipment
Excitation Transformer and Equipment
Steam Packing Exhauster
STEAM SURFACE CONDENSER
YUBA HEAT TRANSFER LLC
3-Vacuum Pumps and Drives
Condenser Neck Piping, Expansion Joints, Turbine Exhaust Expansion Joint, Neck Thermocouples, and Pipe Lagging
2-Boiler Feed Pump Turbine Exhaust Duct Systems, including Butterfly Valves and Pressure-Balanced Expansion Joints
Rupture Discs (BFPTD Exhaust Ducts)
Condenser Tube Cleaning System
Inlet and Outlet Circulating Water Expansion Joints
CONDENSATE PUMPS
RUHRPUMPEN
3-Condensate Pumps with  accessories
Electric Motor Drives
Bently Nevada vibration monitoring system
FEEDWATER HEATERS
YUBA HEAT TRANSFER LLC
LP Feedwater Heaters 1-1A & 1-1B
LP Feedwater Heaters 1-2, 1-3, & 1-4
HP Feedwater Heaters 1-6A/B, 1-7A/B, & 1-8A/B
Drain Coolers 1A & 1B
BOILER FEED PUMPS, BOOSTER PUMPS & S/U PUMP
FLOWSERVE, INC.
2-Boiler Feed Pumps with accessories
2Boiler Feed Booster Pumps, Motors and lube oil systems
110% Startup Boiler Feed Pump, motor and lube oil system
Bently Nevada vibration monitoring system for booster pumps and Startup BFP.  Vibration sensors and proximitors only for main BFPs
1Complete spare BFP inner assembly including rotor, inner casing, balancing device, seals, etc.
1Complete spare  booster pump rotor
STEAM GENERATOR ENGINEER AND SUPPLY
ALSTOM POWER
Air Heaters
Air Heater leakage control system, hot spot detection system and associated PLC control system
PA Fans, Motors, and Lubrication Systems
Pulverizers, Motors, and Lubrication Systems
Feeders
Startup Boiler Circulating Water Pump
Sootblowing System
SCR with Sonic Air Horn Cleaning system
SCR Catalyst
Boiler Building structural steel, roof cap
Boiler Building Platforms
Instrumentation
Heat tracing for His Work
Safety Valves
Vent Stacks
Steam Coils
Coal Piping
Permanent Elevator (Boiler Building)
1-Auxiliary Steam to Air Heater 3A Steam Coil Temperature Control Valve
1-Auxiliary Steam to Air Heater 3B Steam Coil Temperature Control Valve
Boiler Building Steel
Ductwork & Expansion Joints
2 - Separators
Boiler Drain Flash Tank
Low-Energy Piping and Hangers within Building
Feedwater Piping within Building
Feedwater Piping Hangers within Building
Steam Coil Drain Tank
CRITICAL PIPING
B.F. SHAW
Main Steam
Hot Reheat
Cold Reheat
Boiler Feedwater Discharge
Critical Piping Temperature Elements and Thermowells
Temperature elements and thermowells requiring full penetration welds in piping runs in Critical Piping scope.
HIGH PRESSURE VALVES #1, High Pressure Gate, Globe, and Check Valves
FLOWSERVE, INC.
2- Main Steam BFP Turbine Isolation Valves  (Y-Pattern Globe) (6"1-MS-BV-1005-1, 1-MW-BV-1006-1)
2- Feedwater Feed Pump Discharge Valves (16"Y-Pattern Globe) (1-FW-MBV-1010-1, 1-FW-MBV-1011-1)
2- Feedwater Feed Pump Discharge Valves (16"Tilting Disc Check) (1-FW-UV-1010-1, 1-FW-UV-1011-1)
2- Feedwater HP Heater Bypass Valves (10"Gate, Globe) (1-FW-BV-1013-1, 1-FW-MBV-1013-1)
4- Feedwater Recirculation Isolation Valves (10�? 12"Gate) (1-FW-BV-1021-1, 1-FW-BV-1022-1, 1-FW-BV-1023-1, 1-FW-BV-1024-1)
2- Feedwater Feed Pump Prewarm Valves (3"Stop-Check) (1-FW-BV-1028-1, 1-FW-BV-1029-1)
2- Feedwater Feed Pump Prewarm Valves (3"Tilting Disc Check) (1-FW-UV-1028-1, 1-FW-UV-1029-1)
1- Feedwater Startup BFP Discharge Valve (8"Tilting Disc Check) (1-FW-UV-1041-1)
1- Feedwater BFP Booster Pumps LCV Discharge Valve (12"Tilting Disc Check) (1-FW-UV-1009-1)
HIGH PRESSURE VALVES #2, High Pressure Gate, Globe, and Check Valves
WEIR PUMPS
1- Feedwater Startup BFP Discharge Valve (8"Gate) (1-FW-MBV-1041-1)
1- Feedwater BFP Booster Pumps LCV Discharge Valve (12"Gate) (1-FW-BV-1009-1)
1- Feedwater Feed Pump LCV Discharge Valve (12"Gate) (1-FW-BV-1037-1)
4- Feedwater HP Heater Isolation Valves (Gate Valve) (1-FW-MBV-1010-2, 1-FW-MBV-1018-1, 1-FW-MBV-1011-2, 1-FW-MBV-1019-1)
2- Feedwater Feed Pump Discharge to LCV Valves (12"Y-Pattern Globe) (1-FW-BV-1035-1, 1-FW-BV-1036-1)
SEVERE SERVICE CONTROL VALVES
SPX PROCESS EQUIPMENT - COPES VULCAN
1Condensate Pumps Min Flow Recirculation Control Valve (1-CD-FCV-1014-1)
2Main BFP Recirculation Control Valves (1-FW-FCV-1021-1, 1-FW-FCV-1022-1)
2BFP Booster Pump Recirculation Control Valves (1-FW-FCV-1054-1, 1-FW-FCV-1055-1)
1Startup BFP Recirculation Control Valve (1-FW-FCV-1052-1)
1Main BFP Feedwater Supply Control Valve (1-FW-LCV-1037-1)
1Startup BFP Feedwater Supply Control Valve (1-FW-LCV-1040-1)
1Deaerator Level Control Valve (1-CD-LCV-1027-1)
1BFP Booster Pumps Feedwater Control Valve (1-FW-LCV-1008-1)
 




Copyright©2006-2013 Leda Greenpoweer Beijing ICP Reg. No: 10010978
   Fax:0086-10-84161062  E-mail:
[email protected]
[email protected]