MOTOR 3 PHASE 1LA4280 VT 280S NO 281177 IP55 50
HZ KLASSE F 415 DELTA A126 KW75 COS DIA 0.88 RPM
2975 ROTOR KL 10 BS 2613 KT/C OOLANT TEMP 55DEG �?C
GEW/WT .57 T FOR AUX OIL PUMP OF KWUG/T TYPE
V93.1=LUBE OIL SYSTEM AND COMPUSION CH
Motor 3 phase induction
Mounting vertical (V1) with rain shade protection.
Frame size 1LA 4 280 V1 280S
Supply voltage 415 V curent 126 A.
Delta connection IP55 frequency 50Hz. kW 75. PF .88-0.9
Speed 2975. Class F. Temperature rise 55⁰C. Efficiency�?/SPAN>95%
�?Terminal box on top, and cable entry on right side (viewed from driven end). Variable location of connection boxes and cable entries as option. �?Insulation system is designed for temperature class 155 (F). At rated output with line-fed operation, the motors can be used in temperature class 130 (B). �?Self ventilated motors with radial-flow fans (cooling method IC 411 according to IEC 60034-6) as standard, forced air cool with external separately driven fans as option. �?FS 80 ~ 90 motor donot have eyebolt; FS 100 ~ 315 all motors have 2 eyebolts, and FS 355 motor have one eyebolt for transport. Environmental �?Degrees of motor protection IP55 (IEC 60034-5). �?Altitude shall not exceed 1000m above sea-level (IEC 60034-1). �?Allowed air temperature between -20 ºC and 40 ºC (IEC 60034-1). �?Permitted relative humidity: • -20 ºC �?T �?20 ºC�?00 % • 20 ºC < T �?30 ºC�?5 % • 30 ºC < T �?40 ºC�?5 % For higher coolant temperatures and / or site altitudes higher than 1000 m above sea level, the specified motor output must be reduced by using the factor kHT. The results in an admissible output (Padm) of the motor: Padm = Prated • kHT
Foot note: 1) Order other voltages with voltage code 90 and the corresponding Option code (see under "Option") . 2) The types of construction IM B6/7/8, IM V6 and IM V5 without protective cover are also possible as long as no condensation drainage holes (Order code: H03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B3 is then stamped on the rating plate. 3) The type of construction is stamped on the rating plate. When ordering with condensation drainage holes (order code H03), it is absolutely necessary to specify the type of construction for the exact position of the condensation drainage holes during manufacture. 4) The types of construction IM V1 and IM V3 without protective cover are also possible as long as no condensation drainage holes (Order code: H03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B5 is then stamped on the rating plate. 5) The types of construction IM V19 and IM V18 without protective cover are also possible as long as no condensation drainage holes (Order code: H03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B14 is then stamped on the rating plate. 6) For motor with IM B5, IM V1, IM V3, IM B14, IM V18 and IM V19 construction and mounting type, the 16th digit of motor order No. must be "4"; 7) Only for FS80 ~ 160. 8) Without canopy, for protective cover with canopy needed Option code H00. 9) Cable entry on connection box towards the non-drive. Order No. example: Low voltage three phase motor 4-pole, 15 kW, IM B5, 380VD/660VY 50 Hz, IP55, connection box on top and cable entry at right side (view from DE), with separately driven fan. Motor order code: 1LE0001-1DB43-3FA4-Z F70 Motor order code introduction |