695 | Used 2009 PG9171 Gas turbine power plant
Gas Turbine:
Frame size: PG9171
2009 Year
General Electric manufacture
Gas turbine model: Frame 9E
Fuel System: Gas Only
Starting: Electrical Motor
Air Filtration: Self Cleaning
Compressor Washing: On and Off-line Compressor Water Wash
Exhaust System: Side Left
Emissions Control: Gas-Dry Low NOX
Fire Protection: High Pressure CO2
Generator:
Model: 9A5
Frequency: 50 Hz
Power factor: 0.8 lagging (capability to 0.95 leading)
Control Systems:
Gas Turbine: Speedtronic Mark VIe (TMR)
Generator: Control, Excitation, regulation and protection panel
Operator interface: Local and
HRSG:
Manufacturer: Nooter Eriksen
Steam Capacity: 385 t/h at 41 bar, 440 C
History:
Total fired time: 56500 hours
Each 24000 hours a HGPI (Hot Gas Path Inspection) or MI (Major Inspection) service implemented respectively. MI is included HGPI. HGPI is included Combustion Inspection (CI)
2012: HGPI implemented
2015: MI implemented.
Major Inspection at 48K hours | | Used Power Plant | GE-PG9171 | used power plant, equipment, spare parts, prior to sales, or just as information, not accurate or not for specific plant only. | | | |