Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   China Small EPC Contractor   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  
Mail List

E-mail:

     上方导航  
       Homepage  
       Power Generation  
       Top Spare parts  
       spare parts  
       China OEM Equipment and Spare Parts  
       Project Financing   
       Equipments  
       China Small EPC Contractor  
       Transmission  
       Financing-Ebook  
       Contact Us  
       Used Equipment  
       download  
       sitemaps  
       Project-Equipment-Parts-Enquiry  
       供货商Supplier  
       Exchange Link  
       Breaking News  
     下方导航  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > HomePage > Spare Parts > Used Power Plant - Used Power Plant GE-9E.03/.04

Buyer     Inquiry Basket     Supplier     Register


Used Power Plant GE-9E.03/.04


Item NoDescriptionQTYBrandP/NProduct NameDelivery TimeConditionType
480BUDGETARY PROPOSAL For the Supply of 1x 9E.03 50HZ UNITS EQUIPMENT 1 INTRODUCTION This budget proposal has been prepared for the Supply of 1 x Frame 9E.03 gas turbine rated @ 132MW each 50Hz at ISO conditions. Proposal Documents This proposal includes documents in the attached appendix, which are integral part of this proposal: ? Appendix A: Fact Sheet 9E.03-.04 2 SCOPE OF SUPPLY a. Gas Turbine Generator Equipment Gas Turbine 9E.03 50HZ Gas Turbine Quantity 1 Combustion System Standard Combustor Fuel Heavy Fuel / Liquid / Gas Diluent Water Injection Auxiliary Equipment Gas Turbine Package ? Gas Turbine enclosure ? Lubricating Oil and Hydraulic Oil Systems ? Lube Oil Piping and Reservoir ? Fuel Gas Module ? Liquid Fuel Module Generator & Accessories Air Inlet System ? Static - 3 Stage Exhaust ? Diffuser ? Exhaust Silencer + Diverter Damper + Low Stack Fuel System ? Distillate Fuel Heater ? Absolute Separator ? Liquid Fuel Filtering & Forwarding Skid ? Liquid Fuel Filtering Skid Packaged Electronic and Electrical Control Cabinet (PEECC) ? Turbine Control Panel (TCP) ? Generator Control Panel (GCP) ? Motor Control Centre (MCC) ? Battery ? Battery chargers ? Human Machine Interface (HMI) ? Fire Fighting Protection Panel (FFP) Other ? Washing Skid: Water Wash - 15hr Heating ? Fire Protection: CO2 ? 1 LCI PER Unit ? GCB and Non Segregated Bus ? Unit Auxiliary Transformer c. Customer Scope We have listed for your convenience those major scope items which have not been included as the basis of this Budgetary Proposal. Some of these items listed herein could be quoted separately as needed and upon request. This list is not exclusive and not limitative ? Civil Works ? Erection & Commissioning ? Site fire protection and detection system ? Off-base natural gas equipment (treatment station) if necessary ? Step-up transformer ? Cooling System 3 PERFORMANCE The estimated performance rating for these units at ISO conditions are: SC Net Output (MW) 132 SC Net Efficiency (%, LHV) 34.6% SC Net Heat Rate (kJ/kWh, LHV) 10,403 The Estimated Plant level Performance at the flowing parameters Temperature 320C Relative Humidity 85% NOx at base load 75ppm at 15% O2 for HFO Noise 85 db Test Tolerance +/- 1.5% 4 WARRANTY GE standard warranty will be pass through to the buyer: Standard warranty terms are twelve (12) months starting from the date fuel is first combusted in the Unit at the Site or eighteen (18) months from the date of Seller’s Notice of RTS, whichever period shall first expire (the “Warranty Period�?. 5 DELIVERY The unit is in storage in Europe at the moment and has been stored as per OEM specifications and are ready for immediate shipment. Used Power PlantGE-9E.03/.04used power plant, equipment, spare parts, prior to sales, or just as information, not accurate or not for specific plant only.
Pubdate: 2022/4/26 16:56:24


Click add item to inquiry basket      Click Copy Shared LinksInquiry Basket

Pageviews: 1



Statement: Any reference to the OEM part number or other OEM information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.