Email: [email protected]   WhatsApp/WeChat: +0086-13801218512
  
Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   China Small EPC Contractor   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  
Mail List

E-mail:

     上方导航  
       Homepage  
       Power Generation  
       Top Spare parts  
       spare parts  
       China OEM Equipment and Spare Parts  
       Project Financing   
       Equipments  
       China Small EPC Contractor  
       Transmission  
       Financing-Ebook  
       Contact Us  
       Used Equipment  
       download  
       sitemaps  
       Project-Equipment-Parts-Enquiry  
       供货商Supplier  
       Exchange Link  
       Breaking News  
     下方导航  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > HomePage > Spare Parts > Used Power Plant - Used Power Plant Wartsila-18V32E

Buyer     Inquiry Basket     Supplier     Register


Used Power Plant Wartsila-18V32E


Item NoDescriptionQTYBrandP/NProduct NameDelivery TimeConditionType
4701 No. 6 MW/50 hz REBUILT WARTSILA Make HFO fired Power Plant (with accessories) -PRICE: on request Technical specifications: ENGINE DETAILS: Make : Wartsila Model : 7612 Type : 18V32E Year of Commissioning : 1997 Capacity : 6 MW Speed : 750 RPM No. of Running Hours : 1166 from O/H--Total 52560hrs ALTERNATOR DETAILS: Year of Make : 1996 Make : ABB Model : 4552971 Frame : HSG 900 X S8 Rating : 7500 KVA Speed : 750 Rpm Volts : 11000 V Amperes : 393 A Frequency : 50 Hz Connection : Star Insulation : Class F Ambient Temp. : 50 Deg C Excitation : 90 Volt (Dc), 8.9 Amp (Dc) Direction Of Rotation : Anti-clockwise, when looking from driven end. Rating : Continuous ? The 6 MW Set and its auxiliary Equipment are being maintained as per OEM recommendations. OPERATING DETAILS: ? Major overhauling was done in 2005 at 51675 hours. ? Running Hours - 1166 after major overhauling. ? Total running hours �?52841 hours. ? Trial not possible since cooling tower damaged. ? Last trial taken in November 2010. SCOPE OF SUPPLY: 1) Engine complete with common base frame and working platform. 2) Generator complete (ABB Make). 3) Fuel Oil separator without skid, heater, feed pump & piping - Alfa Laval Mopx 207) - 1 No. 4) Lube Oil Separator complete with skid (Alfa laval Mopx 207) �? No. 5) Booster skid contains 2 Pumps with Motors, Filter, De aeration Tank & Heater Unit. 6) Pre Lube Pump With Motor. 7) H.T Water Preheater skid containing pump with motor & heater Unit. 8) Plate Heat Exchangers -3 Nos. (For Lube Oil, HT Water & LT Water) 9) Silencer Unit. 10) Stack. 11) Expansion Water Tank. 12) Ventilation Fans With Motors - 4 Nos. 13) Charge air oil bath filter unit, needs reconditioning. 14) NTC skid contains one pump with motor, heater unit & 300 Liters oil Tank. 15) Feeder skid contains 2 pumps with motors. 16) Maintenance water tank with pump & motor. 17) 2 Nos. of water pumps and motors for room ventilation System. 18) Tank mounted return fuel pump with motor & heater unit. 19) Cooling tower fan drive gearbox connected shaft & motor - 2 Nos. of pumps with motors. 20) 1000 Liters capacity Air bottle. 21) All interconnecting piping for lube, air, water and fuel systems. 22) Air ducting connected from filters to Turbo Charger & exhaust ducting connected from stack to Turbo Charger. 23) Engine Operating Manuals �?1 Set. 24) Integrated Control Panel (ABB Make). 25) Local Control Panels - 5 Nos. (Engine Control, Booster, NTC, Feeder & R/F System Panel). 26) NGR Isolator. COMMON ITEMS: 1. 160 KL HFO Storage Tank - 1 No. 2. 16 KL H.S.D Storage Tank - 1 No. 3. Transfer skid with 2 Pumps and motor, connected piping between storage tank and transfer Unit With LCP - 1 Set. EXCLUSIONS: 1) Buildings and Civil Structures Of Both Engines 2) H.T &L.T electrical equipment connected cables of DG set 3) PLC and connected relays mounted in 6MW set control panel. 4) Stand by pump unit with motor of 6MW set NTC system.Used Power PlantWartsila-18V32Eused power plant, equipment, spare parts, prior to sales, or just as information, not accurate or not for specific plant only.
Pubdate: 2022/4/26 16:56:23


Click add item to inquiry basket      Click Copy Shared LinksInquiry Basket

Pageviews: 1



Statement: Any reference to the OEM part number or other OEM information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.

All the brands and trademarks in the whole domain of the website belong to their own owners and does not mean that we are their authorized partner or dealer. All the information in this website is only for reference, we do not assure its accuracy.

This statement supersedes all other claims and statements on all pages, files, pics and information within this whole web domain.

Copyright©2006-2019 Leda Greenpower Beijing ICP Reg. No: 10010978.   Fax:0086-10-84161062  E-mail: [email protected]

JingGongAnBeiAn 11010802035914 Hao