Used Power Plant BBC-GT13B
Item No | Description | QTY | Brand | P/N | Product Name | Delivery Time | Condition | Type |
---|
379 | FOR SALE
Qty. 1 Second-hand gas turbine power plant (GTPP)
The GTPP consists of four fossil-fuelled (fuel: light heating oil) gas turbines.
Mfc.: Brown Boveri (later ABB and now Alstom) Type: BBC GT13B
They are operated without a waste heat boiler.
First commissioning was in: 1973 Stopped: 2017
Total electrical power: 252 MW
Performance consists of 4 single turbines together with each 63 MW of electrical power.
The plant was as quick start system running, which within about 5 min. has run up to full load. The gas turbine plant was used to cover peak loads.
Offered here is a gas turbine plant as a complete system. The system has an efficiency
of η = 27% and is operated with light fuel oil.
The efficiency can be increased (water tank has to be added �?GOD system).
Price: EUR 3,450,000.00 As is where is!
Technical Data
Fuel: Heating oil EL Normal outside air pressure: 1.01303bar
Normal outside air temperature:15°C Max.cooling water temperature: 25°C
Compressor
Suction pressure: 1.0091bar Pressure ratio approx.: 10.2
Air volume: 281 m³/s Number of stages: 17
Revolution: 3000 RPM Shaft diameter: 1400mm
Gas turbine
Inlet temperature measured: approx. 940°C Mix temperature: approx. 890°C
Back pressure at the outlet flange of the exhaust gas diffuser: 1.01891bar
Number of stages: 5 Revolution: 3000 RPM
Shaft diameter: 1400mm Amount of exhaust gas: 349kg/s
Exhaust gas temp.: approx. 444°C
Combustion chamber �?Qty. 1
Number of burners: 1 Number of ignition device: 1
Generator
Nominal apparent power at 35 ° C cold air inlet temperature: 74500 kVA
Rated power factor: approx. 0.85 Nominal voltage: 10,5 kV ± 7,5 %
Rated current 4100 A Neutral -Short circuit ratio (saturated): 0.48
Subtransient reactance Xd ": 11.8 % Transient reactance Xd ': 18.0%
Synchronous reactance Xd (unsaturated): 228%
Asymmetrical peak value of the initial short-circuit current: 88 kA
Continuous short-circuit current (three-pole): 5.8 kA
At a cold gas temperature of 15 °C, the maximum nominal apparent power is: 84.0 MVA
According to DIN EN 60034 VDE 0530
Throw-off device
Three-phase squirrel-cage motor air-cooled Nominal frequency: 50 Hz
Synchronous revolution: 1500 RPM Nominal voltage: 6 kV
Rated power approx.: 4000 kW Rated power factor: approx. 0.95
Three-phase slip ring rotor generator (air-cooled) for coupling drive machine
Rated power: approx. 3750 kW Synchronous revolution: 1500 RPM
Rated power factor: approx. 0.95 Nominal frequency: 50 Hz
Excitation system
Thyristor excitation system
Rated load excitation requirement: 900 A/220V
Cover voltage at least: 1.6 times Exciter speed at least: 0.6 persec.
Overload exciter demand: (82 MVA) 970 A/240V
Cooling water
At a cooling water inlet temperature of maximum 25 ° C is for the generator air cooling, the
lubricating oil cooling and control oil cooling of the gas turbine group a total cooling water of approx. 265 m³ / h required. | | Used Power Plant | BBC-GT13B | used power plant, equipment, spare parts, prior to sales, or just as information, not accurate or not for specific plant only. | | | |
Pubdate: 2022/4/26 16:56:23 |
|
Click add item to inquiry basket Click Copy Shared Links | Inquiry Basket |
Pageviews: 1
|
|
Statement: Any reference to the OEM part number or other OEM information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.
All the brands and trademarks in the whole domain of the website belong to their own owners and does not mean that we are their authorized partner or dealer. All the information in this website is only for reference, we do not assure its accuracy.
This statement supersedes all other claims and statements on all pages, files, pics and information within this whole web domain.
|
|