286 | THE FOLLOWING CONDENSING TYPE STEAM TURBINE GENERATOR SET IS AVAILABLE FOR SALE WITH US WITHIMMEDIATE DELIVERY: 1 No. - 18.7 MW ANSALDO (1994) make, Condensing type Steam Turbine Generator Set having the following technical specifications:
Year of Manufacture :1994 Year Retired :2010 Condition :Excellent Status :Installed on Foundation
TURBINE DETAILS: Manufacturer :Ansaldo Energia S.P.A.
Rated Power :18,700 kW
HP Admission
Rated Inlet Flow
(fullycondensing) :60,985 kg/h
Rated Inlet Pressure :70 bara
Rated Inlet Temperature :500 ºC
MP Extraction
Rated Flow :0 �?22,000 kg/h
Rated Pressure :14.5 bara
Rated Temperature :315 ºC
LP Admission
Rated Flow :13,320 kg/h
Rated Pressure :6.5 bara
Rated Temperature :280ºC
LP Extraction
Rated Flow :0 - 13,500 kg/h
Rated Pressure :6 and 6.4 bara
Rated Temperature :280ºC
Exhaust Conditions
Rated Flow (fully condensing):73,945 kg/h
Rated Pressure :0.088 bara
Rated Temperature : 70ºC
Rated Speed :5,512 RPM
GEARBOX DETAILS:
Manufacturer :MAAG
Rated Power :18,711 kW
Input Speed :5,512 RPM
Output Speed :1,500 RPM
Gear Ratio :3.675:1 AGMA SF Rating :1.452
GENERATOR DETAILS:
Manufacturer :ANSALDO
Rated Apparent Power :23,375 kVA
Power Factor :0.8
Active Power :18,700 kW
Rated Voltage :11,000 V +/- 10%
Rated Current :1,227 A
Phases :3
Rated Speed :1,500 RPM
Frequency :50 Hz
Rated Ambient Air Temp :400C
Rated Water Temp :350C
Insulation Class :F
Connection :Star
CONDENSER DETAILS:
Type :Air Cooled
Manufacturer :FBM
Dissipated Thermal Rating:44 MWt
Flow Rating (Normal/Max):71,295 / 97,200 kg/h
Number of Units :16
Number of Fans :8
Air Flow :512,000 m3/h
Electric Motor :30 kW/380C/3ph | | Used Power Plant | Ansaldo Energia S.P.A.-18.7mw | used power plant, equipment, spare parts, prior to sales, or just as information, not accurate or not for specific plant only. | | | |