Name of Used or Surplus Equipment/Project: | 3516E Diesel Engine Nominal Rating 3500kVA Output power 2800kW 8 Set | Brand name of Equipment: | Caterpillar | P/N of Equipment: | 3516E | Industry: | Fluid Power Generation Industry | Summary Briefs on the equipment: | | Origin of Main Product: | | Year of Production of Main Equipment: | | Current Country located: | | Original Packing: | | Warranty: | | Documents: | | Dismantled or on site: | | Can be Test Run or Not: | | Year of Shutdown: | | Year of Overhaul: | | Total Operation Hours: | | O&M log: | | Current Condition: | | Dismantling, packing transportation Serviece: | | Refurbishment Services: | | Site installation and commissioning or Supervision: | | Role: | | Already Sold or not: | | Time of first Sold: | | rough budget or contract value in USD: | | Payment Terms: | | File Link: | NO_File |
Section 1.1 1.2 Valve 3516E Generator Technical Data 1 ALTERNATOR ELECTRICAL DATA LSA 54.2 UL17 / 4P LS Reference: test1 Date: V6.09b - 01/2022
Main data: Power: Voltage: Rated voltage range: Power factor - Lagging: Nominal current: Insulation / Temperature rise: Cooling: | C |
|
|
|
| 3 500 | kVA V | 2 800 | kWe | 2 894 | kWm Hz rpm | 400 +5% / -5% 0,8 5 052 H / H IC01 | Frequency: | 50 |
|
|
| Speed: | 1500 |
|
|
|
| A | Phases Connexion | 3 Star serial p2/3 - 6 Wires |
|
|
| Winding type: |
|
|
|
|
| Winding: |
|
|
|
|
| Ambient temperature: Altitude: Duty: Base Rating | 45 1000 | °C m |
|
|
| Overspeed (rpm) | 1800 |
|
|
|
| Total Harmonic Distortion (THD) < 3,5% |
|
|
|
|
|
1 1 1 1 1 1 1 1 1 1
Efficiency ( Base 2800 kWe ) | IEC |
|
|
| 25% | 50% | 75% | 100% | 110% |
Power factor - Lagging: 0,8 91,88 | 95,36 | 96,37 | 96,75 | 96,83 | 92,22 | 95,79 | 96,88 | 97,35 | 97,46 |
1 Power factor - Lagging: 1 1 Reactances (%) - ( Base 3500 kVA ) Unitary impedance ( 1 per unit ) = 0,045714 ohms Unsaturated Saturated Unsaturated Saturated Direct axis Quadrature axis Synchronous reactance Xd 162 107 Xq 83 54 1
Transient reactance Subtransient reactance | X'd X"d |
1 1 Negative sequence reactance X2 11,5 9,8 X0 2,1 Zero sequence reactance 1 Xl 5,5 Stator leakage reactance Xr 14,3 Rotor leakage reactance Kc 0,94 Short-circuit ratio 1 Time constants (s) Direct axis Quadrature axis
Open circuit transient time constant Short-circuit transient time constant Open circuit subtransient time constant Subtransient time constant | T'do T'd T''do T"d | 4,35 0,498 0,071 0,042 |
T'qo | NA | T'q | NA | T''qo | 0,257 | T"q | 0,038 |
1 1 1 1 Ta 0,067 Armature time constant 1 Resistances (%)
Armature resistance | R0 | X/R ratio (without unit) | R2 |
1 resistance Voltage accuracy: 0,25% Maximum inrush current for a voltage dip of 15%: 3699 kVA when starting an AC motor having a starting power factor between 0 and 0.4 Rating is provided for the specified temperature rise, by resistance measurement according to IEC60034-1 According to: I.E.C. 60034.1 - 60034.2 - NEMA MG 1-32 Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, 2022-09-01 test1 rev. 1 Page 1 / 5 1 ALTERNATOR MAIN CURVES LSA 54.2 UL17 / 4P LS Reference: test1 Date: 3500kVA - 400V - 50 Hz V6.09b - 01/2022 Umax + 5% 420 V Capability Curve Un 400 V Umin - 5% 380 V Efficiency Curves According to: IEC 2022-09-01
92,22 |
|
|
| 95, | 78 | 96, | 76 96,83 | 96, | 88 |
|
| 97, | 35 97,46 |
|
| 91,88 |
|
|
| 95, | 35 |
|
| 96, | 37 |
|
|
91,0 92,0 93,0 94,0 95,0 96,0 97,0 98,0 25 50 75 100 125 Efficiency - Rendement en % Load (% of rated kWe) - Charge (% kWe nominaux) PF 1 PF 0,8 PF 0,1 PF 0,2 PF 0,3 PF 0,4 PF 0,5 PF 0,6 PF 0,7 PF 0,9 PF 0,8 PF -0,1 PF -0,2 PF -0,3 PF -0,4 PF -0,5 PF -0,6 PF -0,8 PF -0,9 PF -0,7 0.8 PF -0.95 PF 0.95 0 0,2 0,4 0,6 0,8 1 -1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 kWe / rated kVA kVAr / rated kVA kWe / rated kVA kVAr / rated kVA test1 rev. 1 Page 2 / 5 1 ALTERNATOR MAIN CURVES LSA 54.2 UL17 / 4P LS Reference: test1 Date: 2022-09-01 3500kVA - 400V - 50 Hz V6.09b - 01/2022 Stator Current decrement curves Symmetrical phase to neutral short-circuit initial A 14,1 x In 71 107 Symmetrical two phase short-circuit max 45 555 A 9 x In In = 5052 A Symmetrical three phase short-circuit value A 10,6 x In 53 776 Thermal Limit Asymmetrical three phase short-circuit IP A 24 x In 121 235 5 0 10 15 20 25 30 0,001 0,01 0,1 1 10 100 short circuit at generator terminals - court circuit aux bornes Time - Temps (second.) Isc ( Short circuit current per rated current - Courant de court circuit / In ) Symmetrical three phase short circuit (rms) Asymmetrical three phase short circuit (peak)
8 6 4 2 0 10 12 14 16 0,001 0,01 0,1 1 10 100 short circuit at generator terminals - court circuit aux bornes de l'alternateur Time - Temps (second.) Isc ( Short circuit current per rated current - Courant de court circuit / In ) Symmetrical Phase to neutral short circuit Symmetrical two phase short circuit Symmetrical three phase short circuit
test1 rev. 1 Page 3 / 5 1 ALTERNATOR MAIN CURVES LSA 54.2 UL17 / 4P LS Reference: test1 Date: 2022-09-01 3500kVA - 400V - 50 Hz V6.09b - 01/2022 Transient Voltage Variation 0% 5% 10% 15% 20% 25% 30% 35% 0 1 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000 9 000 10 000 Voltage dip - Chute de Tension (% of rated voltage) PF = 0,8 PF = 0,6 PF = 0,3 PF = 0 100% Transient voltage dip curve versus load impact Load inrush - Appel de charge - per kVA 0% 5% 10% 15% 20% 25% 30% 0 1 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000 9 000 10 000 Voltage rise - Surtension (% of rated voltage) PF = 0,8 100% Transient voltage rise curve versus load rejection kVA shedding at P.F. Delestage de charge - per rated kVA test1 rev. 1 Page 4 / 5 1 ALTERNATOR MAIN CURVES LSA 54.2 UL17 / 4P LS Reference: test1 Date: 2022-09-01 3500kVA - 400V - 50 Hz V6.09b - 01/2022 Thermal Damage Curve Unbalance Load Curve Stator Earth Fault Current 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 1 10 100 1000 10000 Maximum duration - durée maximum (second.) Stator current (per rated current) 3 2 1 0 1 10 100 1000 10000 Maximum duration of fault - Durée max. du defaut (second.) Negative phase sequence Current courant inverse (per rated current) 0 25 50 75 0 1 2 3 4 5 6 7 8 9 10 11 12 Maximum duration of fault - Durée max. du defaut (second.) Fault Current - Courant de défaut (A)
C | : | Ex | te | nsi | ve | da | m | ag | e |
| B | : | Co | ns | id | era | bl | e d | a | ma | ge | A | : | Ac | ce | pt | ab | le | da | m | ag | e | A |
|
|
|
|
|
|
|
|
|
|
B C test1 rev. 1 Page 5 / 5