Email: [email protected]   WhatsApp/WeChat: +0086-13801218512
  
Homepage   |   Power Generation   |   Top Spare parts   |   spare parts   |   China OEM Equipment and Spare Parts   |   Project Financing    |   Equipments   |   China Small EPC Contractor   |   Transmission   |   Financing-Ebook   |   Contact Us   |   Used Equipment   |   download   |   sitemaps   |   Project-Equipment-Parts-Enquiry   |   供货商Supplier   |   Exchange Link   |   Breaking News  
Mail List

E-mail:

     上方导航  
       Homepage  
       Power Generation  
       Top Spare parts  
       spare parts  
       China OEM Equipment and Spare Parts  
       Project Financing   
       Equipments  
       China Small EPC Contractor  
       Transmission  
       Financing-Ebook  
       Contact Us  
       Used Equipment  
       download  
       sitemaps  
       Project-Equipment-Parts-Enquiry  
       供货商Supplier  
       Exchange Link  
       Breaking News  
     下方导航  

Diesel Generator Proposal

Power Plant Proposal
Required Information for Power Plant Project design and quotation

Home > HomePage > Equipment > New Equipment > China brand - Cryogenic ASU Oxygen production 50Nm³/h China brand KDO-50

Buyer     Inquiry Basket     Supplier     Register


Cryogenic ASU Oxygen production 50Nm³/h China brand KDO-50


Name of New Equipment:Cryogenic ASU Oxygen production 50Nm³/h
Brand name of Equipment:China brand
P/N of Equipment:KDO-50
Industry:General Industry
Summary Briefs on the equipment:
Origin of Product:
Original Packing:
Warranty:一�� One Year
Installation, commissioning service:
Role:
Already Sold or not:
Time of first Sold:
Already sold coutry or region:
Rough budget or contract value:  货币选择
Payment Terms:
File Link:ASU KDO-50 - 中�.docx

1.    Project Overview

 

According to the friendly negotiation between the two parties, the scope of responsibilities is divided as follows:

1.1.   The seller undertakes the scope of responsibility within the boundary of the air separation plant:

(1)   Process design, instrument electrical design, equipment design, and engineering design of the air separation plant.

(2)  The scope of supply of process equipment is as follows: 1 screw compressors, 1 air pre-cooling unit, 1 molecular sieve purification system (including molecular sieve and alumina), 1 fractionation tower system (including pearlescent sand), 2 sets Complete supply of expander system, 1 oxygen booster, 1 sets of filling platoons and instrument control system, electrical system, spare parts and special tools used in supporting the above process equipment; see "Appendix 5 Process Equipment and Instrument Electricity" for details Scope of supply".

(3)    The installation materials supplied by the seller within the boundary of the air separation plant include: process piping, cryogenic liquid piping from cold box to cryogenic storage tank, steel structure pipe gallery and supports, steel structure equipment and valve maintenance platform, Cable tray, power cable, instrument cable, instrument root valve, instrument sampling pipe (stainless steel), anti-corrosion and thermal insulation materials, cutting gas, solder and other auxiliary materials required for installation work.

(4)   The installation work in the boundary area of the air separation plant includes the following: the installation of the equipment mentioned in serial number (3), the installation of ancillary instruments and electrical appliances, the installation of process pipes, steel structure pipe gallery and brackets, steel structure equipment and valve maintenance platform Installation, installation of power cables and instrument cables, installation of cable trays, anti-corrosion and heat preservation work, filling work of molecular sieve purification system packing, filling work of pearl sand, the insulation material in the cold box, linkage test work, official start-up work, flaw detection, Also includes the installation tools required for the above installation work.

(5)   Junction point: the junction point of high and low voltage cables is bounded by the inlet end of the high and low voltage cabinet of the seller; the circulating water is connected by the buyer to 1 meter outside the boundary of the air separation unit; the junction point of the product liquid is at the liquid nitrogen storage tank; nitrogen gas It is the interface of the buffer tank before the out-of-bounds area;

(6)   Performance assessment, document delivery, technical service and after-sales service related to the air separation plant.

(7)  Assist the buyer to complete other work related to the air separation plant.

1.2.  The buyer undertakes the scope of responsibility within the boundaries of the air separation plant:

(1)   Responsible for the preliminary survey and detailed survey of the land within the boundary of the air separation plant, as well as the three connections and one leveling work within the boundary.

(2)    Responsible for the civil works in the boundary area of the air separation plant (mainly


 

 

 

 

 

 

 

 

greening work, central control room, power distribution room, pipe trench and cable trench), compressor workshop and Driving in the pump room, electrical professional lightning protection and anti-static, factory lighting, equipment lighting and telecommunications, structure, water supply and drainage, inspection and testing, security monitoring, HVAC, fire engineering design, materials, and construction.

(3)    Water, electricity, pressure test gas and mechanical materials for the commissioning and start-up of the air separation plant.

The production process of this air separation unit is a domestic advanced process, and the main equipment is imported or domestic advanced.

The device has many advantages such as high safety, reliable operation, strong operability and low energy consumption.

 

2.   Basic conditions of device design

 

(subject to the parameters provided by the buyer)

 

 

 

3.1 Atmospheric conditions design point


 

Atmospheric pressure

KPa�?/span>A�?/span>

 

Environment Temperature

30�?/span>

 

Relative humidity

 

70%

 

Oxygen content of Hb

 

20.95% O2

 

3.2 Atmospheric temperature


 

Maximum temperature

35�?/span>

 

Minimum temperature

-25�?/span>

 

3.3 Seismic intensity

 

6 degree

 

3.4 Raw material air miscellaneous conditions


 

CO2

�?/span>350ppm

 

C2H2

�?/span>0.5ppm

 

H2

 

<0.7ppm

 

CO

�?/span>0.5ppm

 

N2O

 

<0.3ppm

 

SOX

 

<0.2ppm


 

 

 

 

 

 

 

CnHm (regardless of C2H2)

�?/span>8ppm

 

Dustiness

30mg/m³

3.5 Utility project condition�?/span>


 

3.5.1 Cycling water


 

Inlet temperature

33�?/span>

 

Temperature rise

10�?/span>

 

Inlet pressure

 

0.5 Mpa (G)

 

Pressure of return water

 

0.25 Mpa (G)

 

Dirtiness resistance

3.4*10-4 m³·K/M

3.5.2 Power supply�?/span>


 

Standard power supply

380V�?/span>220V

 

Frequency

 

50+0.5/-0.5 Hz

 

3.5.3 Instrument air (supplied by equipment after start-up)

 

Pressure

 

0.5MPa

 

Temperature

32�?/span>

 

Dew point

-40�?/span>

 

Flow

100Nm³/h

 

3.   Main technical parameters of the device

 

3.1  Output and purity

3.1.1  Main production A

Product

Output

Purity

Pressure MPa

Temperature �?/span>

Oxygen

50Nm³/h

�?/span>99.6%

15

Normal

*Remark�?/span>

1.    To make out product by varying the working condition.

2.    The pressure of the liquid product is calculated based on the 0 elevation of the cold box. Nm³

/h refers to the state of 0°C and 760mmHg, and the pressure is gauge pressure unless otherwise specified.

3.    The standard output to be 100m3/h, while it is adjustable to switch at range of 50m3 to 105m3 so as to save power consumption when you need less output.

 

4.2 Nitrogen dew point

�?/span>-60�?/span>

4.3 Device variable load capacity range

50-105%

4.4 Device heating and thawing time

�?/span>24 hours

4.5Device start up time


Running expander to reach purity

�?/span>12-16 hours

4.6. Temporarily stop and restart to produce oxygen�?/span>

Stop by 8   hours

4 to 6 hours to produce oxygen

Stop by 24 hours

8 to 10 hours to produce oxygen

 

 

5.  Utilities consumption

 

5.1.       The following process air (including instrument air) is required for the air separation unit of the raw material air to produce the above products

Raw material of air gas flow�?nbsp;                    600Nm3/h

Air pressure�?nbsp;                          1.0 MPa(G)

5.2 Main Consumption

 

 

No.

 

 

Device Name

 

380V

Water

Consumption

 

Qty

 

 

Remark

shaft/motor

power KW/set

 

t/h

 

Set

1

Air Compressor

80/90


1


2

Air Precooling Unit

10/13

6

1


3

Electric heater

11/30


1

4h auto switch

4

Instrument control system

3/3


1


5

Cryogenic Liquid Pump

8/8


1


Total shaft power

112

6





LC_Guid:EED79DE2C2320848BC4D4FCED92DBA75
Pubdate: 2024/7/1 21:28:47


Click add item to inquiry basket      Click Copy Shared LinksInquiry Basket

Pageviews: 1



Statement: Any reference to the OEM part number or other OEM information is for the purpose of identification only and does not imply that the part was manufactured by the Original Equipment Manufacturer.

All the brands and trademarks in the whole domain of the website belong to their own owners and does not mean that we are their authorized partner or dealer. All the information in this website is only for reference, we do not assure its accuracy.

This statement supersedes all other claims and statements on all pages, files, pics and information within this whole web domain.

Copyright©2006-2019 Leda Greenpower Beijing ICP Reg. No: 10010978.   Fax:0086-10-84161062  E-mail: [email protected]