 | 2.1 CLIMATIC CONDITIO 2.1.1 ISO Conditions  .   Air   
temp. to turbocharger inlet         
27 deg. C .     
Atmospheric pressure                    
750 mm Hg  .     
Relative humidity                    
60 %  .     
Water temp. at charge air cooler inlet 27 deg. C 2.1.2 Site Conditions (Assumed)  .   
Air temp. to turbocharger inlet       
45 deg. C  .     
Atmospheric pressure              
750 mm Hg  .     
Relative humidity                    
60 %  .     
Water temp. at Cooling tower outlet  32   
deg. C  2.2 Rating of the D.G.set    
 2.2.1 
Under above mentioned site conditions           
---------------------------------------------                     
Rating at   Alternator   
Rating at                     
engine      efficiency   
alternator                     
crankshaft             
terminal(MCR)                        
KWm       (   
% )     KWe     
KVA  (0.8 pf)     
---------------------------------------------   Nominal   
1103           
90.7        
1000     
1250        
Running     -----------------------------------------------   Note : COP rating will be 90 % of 
MCR | 
 
 | 
| -------------------------------------------------------------------------------------------
 
 |